High-pressure cleaners. Batch - 92/9300 - ST 1500
Date: 18/4-2017
Instruction manual
Page:
15 of 36
Kent hojtryk\Clean-9200-9300-1500\Brugs-9200-6300-1500-EN-c.doc
The machine itself can be washed with e.g. standard auto shampoo, but the electrical parts must only
be cleaned by high-pressure air and wiped off with a clean cloth. Only when cold.
Damages on the varnish on the frame must be polished, thereafter primer plus finishing paint (single
component finishing paint).
General:
Repeated fuse drop-outs may be due to faults in the control or the electrical devices, and fault current
can cause electric shock. (230 volt or 400 volt)
Maintenance must only be carried out by an authorized technician who can detect the fault and carry
out a correct repair prior to using the high-pressure cleaner again.
Disposal of machine:
-
If you decide not to use the machine any longer, we recommend that you make
the machine unusable by removing the electrical wire.
-
It must always be kept out of reach of children.
-
The machine cannot be disposed of as is, therefore the most uniform parts
must be dismantled and collected for disposal at a public collection station.
-
Dismantled parts must not be used as spare parts.
Decalcification:
Carried out when needed and is
important
to prevent clogging of the tube coil in the boiler. Fill with
water and acetic acid in the mixture proportion 1 portion of acetic acid and 10 portions of water, leave
the mixture for a couple of hours followed by flushing of loose pieces of chalk and dirt. An extra
treatment may be required if the water contains much chalk in order to avoid a later clogging of the
nozzle on the pistol.