TROUBLESHOOTING
Trouble
Possible Cause
Remedy
The motors do not turn on; no warning light turns
on
The battery terminals (50) are disconnected
Connect
The batteries (50) are discharged
Charge
The warning lights (62, 63, 64) lash
simultaneously
The brush motor is overloaded
Use a different kind of brush
There are foreign materials (tangled threads,
etc.) preventing the brush from rotating
Clean the brush hub
The vacuum system motor does not turn on
The fuse is blown
Replace
The dirty water vacuuming is insuficient
The recovery water tank (31) is full
Empty
The vacuum grid (46) is clogged or the loat
is closing
Clean the grid and check the loat
The vacuum hose (22) is disconnected from
the squeegee (11) or it is damaged
Connect
The squeegee (11) is dirty, or the squeegee
blades (13, 14) are worn or damaged
Clean the squeegee or replace the blades
The recovery water tank cover (6) is not
properly closed, or the gasket (42) is
damaged
Check and/or clean the seating surface or
replace the gasket
The recovery water tank (31) is dirty (clogged
drain hole)
Clean
The solution low is insuficient
The solution ilter (20) is dirty
Clean
The squeegee leaves marks on the loor
There is debris under the squeegee blades
(13, 14)
Remove the debris
The squeegee blades (13, 14) are worn,
chipped or torn
Replace the blades
For further information refer to the Service Manual, available at any KENT Service Center.
SCRAPPING
Have the machine scrapped by a qualiied scrapper.
Before scrapping the machine, remove and separate the following materials, which must be disposed of properly according to the
Law in force:
Battery
–
Brushes
–
Plastic hoses and components
–
Electrical and electronic components (*)
–
Refer to the nearest KENT Center especially when scrapping electrical and electronic components.
(*)
https://harrissupplyind.com - To Order Parts Call 608-268-8080