background image

 

 

                   

S-MIX-PRO1600 Customized Input 

Output Hybrid Matrix Switch 

 

                    Operation Manual

 

 

 

 
 
 

Version

V1.01.01 

2018-3 

Kensence  (shenzhen)  Technology  Development  CO.,LTD

Содержание S-MIX-PRO1600

Страница 1: ...S MIX PRO1600 Customized Input Output Hybrid Matrix Switch Operation Manual Version V1 01 01 2018 3 Kensence shenzhen Technology Development CO LTD...

Страница 2: ...structions 5 6 3 PC control software operation instructions 9 6 3 1 Switching Operation 12 6 3 2 Input Output Board Control Resolution Name Change etc 12 6 3 3 Scene save operation 14 6 3 4 Scene reca...

Страница 3: ...iny days or when not in use for a long time Please do not put anything upon the cables or tread the cables To avoid damaging the device please turn off power supply before plugging cable into the devi...

Страница 4: ...other occasions 2 Product Features Support 16 channel mufti type video interface any configuration for input or output 16 way arbitrary combination Single card single signal port design configuration...

Страница 5: ...device in the same order 5 If all devices are connected properly every display device should display the specified signal to make sure the devices are normal If one of the displays failed to receive s...

Страница 6: ...I AUDIO 3GSDI HDBaseT H 264 Fiber IP streaming Static protection Human body discharge mode 8kV air gap discharge 4kV contact discharge Input voltage Power supply 100VAC 260VAC 50 60 Hz Internationale...

Страница 7: ...ernetEthernet Color space Support RGB444 YUV444 YUV422 color space support x v Color extended color gamut standard Transmission distance HDBaseT technology transmits 70M Cat 6 cable H264 technology tr...

Страница 8: ...er indicator Constant light when power is on ACTIVE data transmission indicator Network network connection status indicator 2 7 inch touch screen matrix can be controlled through the touch screen 3 RS...

Страница 9: ...he right side of the interface There are 13 scenes from 01 to 13 on the right side of the interface for users to use Select any number from 01 to 13 and click SAVE to save the scene 00 is the current...

Страница 10: ...yed Click Load Call the selected scene 00 is the matrix s current input output status do not select Select Scene 8 as shown in the figure below and click Load to invoke 3 Matrix setting Click Settings...

Страница 11: ...following figure Video backup switch The operation is similar to that of the buzzer Click the white bar next to Backup to pop up the numeric keypad enter on off click ENTER and then click Save to save...

Страница 12: ...ing figure 6 3 PC control software operation instructions The cloud media signal management platform is a green software Double click the main program to open and use it and control it through RS232 s...

Страница 13: ...f the matrix in the same network segment in the online port of the network port Select the computer s IP address click the SETUP button on the matrix touch screen to view the matrix network address an...

Страница 14: ...port connected to the matrix for example COM2 then select at the serial device COM2 click serial connection when all the buttons in the lower right corner show green the connection is successful Clic...

Страница 15: ...gnore the USB Audio option As shown in the figure below there is a green rectangle indicating that there is a board online When you switch select input port and then select output port then click appl...

Страница 16: ...u can set the output signal of this circuit In the control column we can The camera and other devices connected to the circuit board card are controlled this function needs to obtain relevant informat...

Страница 17: ...SAVE key to move the current matrix The switching status is saved as a scene Figure6 3 6 scene save 6 3 4 Scene recall Click the SCENE button to pop up the interface as shown in Figure 6 3 7 Select th...

Страница 18: ...equals param length plus 12 Convert to hex Synchroniz ation Header 2BYTE Packet Length 2BYTE Packet Count 2BYTE Method 1BYT E Comman d 2BYTE Paramete r Length 2BYTE Parameter s n BYTE CRC 1BYTE 0x55 0...

Страница 19: ...6 3 8 TV wall configuration As shown in the above figure the 4 areas represent 4 display screens Double click each area to set in sequence If we select 1 for the input signal double click the first ar...

Страница 20: ...S MIX PRO1600 17 Figure6 3 9 Set the input and output relations of each area Figure6 3 10 Use mouse drag to splicing...

Страница 21: ...utton to select the serial port of the connection matrix and the device to be upgraded then double click the upgrade file to select the software to be upgraded and then click to start the upgrade Afte...

Страница 22: ...nt to add into the root directory of the Plugins folder then open the sys_config ini file and add the path after PLUGINS_LIST for example PLUGINS_LIST Plugins SplicerControl Splicer exe Plugins stc is...

Страница 23: ...e6 3 16 encoder decoder switching To achieve the preview function must be the encoder of the RTSP stream as shown in Figure 6 3 17 click the IP of the encoder and gateway encoder click the switch and...

Страница 24: ...Type Control command Function description Operation commands aXb take Switch the input of a road to the output of b road aX1 b take Switch the input of a road to the output of 1 b road aXb1 b2 b3 take...

Страница 25: ...so on to 40 cut 40 Send command NXN Take 6 save the current state command save Y Example To save the current status to the seventh storage unit enter save7 7 Call the stored unit instruction recall Y...