Fig8.2.2 software interface
Fill in the correct serial number,communication protocol, baud rate, data bits, stop bits,
parity bit in the parameter configuration area,can input command in command input area
to control the local or remote receiver.
RS232 control command
Communication protocol: baud rate: 9600 data bits: 8 stop bit: 1: no parity bit
RS232 Command
Function description
Return code
Control host command
/*Type;
Query matrix model
MODULAR3232-N
/%Lock;
Lock the front panel button
System Locked!
/%Unlock;
Unlock the front panel button
System Unlock!
/^Version;
Query software version
Vx.x.x
/:MessageOff;
Closes the serial port returns,returns only
" SWITCH OK!" character information.
Closed The
Message Return.
/:MessageOn;
Open the serial port return
Enabled The