51109IV ASSEMBLY INSTRUCTIONS
PUMP SAFETY & TROUBLESHOOTING
To clean the pump
Unplug the pump from the electrical
outlet. Use a small soft brush or place it
If the pump fails to run:
• This pump has an overheating protection feature that will turn off
the pump when it becomes too hot while not covered with water.
It may take a few minutes for the pump to cool down once it is
submerged in water again. Note: the pump may cycle on and off
as it cools and heats if not covered with water.
• Pump may be air locked, unplug and plug pump in several times to
clear trapped air.
• Check circuit breaker, or try a different outlet.
• Check tubing for kinks and obstructions.
• Clean out any algae buildup.
• Remove the front cover & impeller cover to access the impeller area.
Turn the rotor to ensure it is not broken or jammed.
With low flow rate, the pump will spew or “burp”:
• Check the water level to make sure the pump is completely
submerged, water should always be above the min fill line (not
all water features include min fill line).
under a water stream to remove debris.
To keep water clean
Periodically change water
to prevent algae buildup.
Tube
Suction cup
Pump housing
Back cover
Filter/
Front cover
Regulator
Impeller cover
Rotor/Impeller
Содержание 51109IV
Страница 1: ...Care and Instruction Manual KNIGHT SMALL BIRDBATH...
Страница 12: ...www kenroyhome com...