background image

KENNEDY

thoroughly recommends reading these instructions before

using the Digital Caliper, even if you have used one before. Reading these

instructions carefully and understanding them fully will enable you to

perform tasks correctly.

FITTING/REPLACING BATTERY

1. Unscrew the back of the caliper with the screwdriver provided and insert the b side 

facing up. Inserting the battery upside down may result in caliper failure.

2. If the display on the digital caliper does not show “0.00” after the battery change, remove 

battery and insert again.

3. Your Kennedy digital caliper is supplied with one 3V lithium battery (CR2032).
4. Replacing the battery. When the digital display shows a battery symbol with a B in the 

middle of the symbol, this means the battery is flat and needs replacing. Follow step 1 

above on how to insert the battery.

PREPARATION

1. When using the caliper for the first time after purchase, wipe away the rust-preventive oil 

on the caliper with a soft cloth. 

2. Install the supplied battery, (see fitting/replacing battery section above).
3. Before measuring, wipe the sliding surfaces and measuring faces to remove dust and dirt.
4. Switch on the caliper by pressing the mode button. Check that the function keys and the 

LCD are working properly.

5. Close the jaws and make sure that there is no light observed between the jaws, if the 

caliper is not already reading “0.00mm” press the “set” button once.

6. Please note that the digital caliper must be switched off after use and should be kept in

its original box.

WARNING!

l

DO NOT

use an electric engraving pen on any part of the caliper as this 

can cause damage to the caliper and its circuitry.

l

It is advised to remove the battery from the caliper when it is not in use 

for long periods of time.

FUNCTIONS/IDENTIFICATION

1. Beam

2. Inside measuring face

3. LCD display

4. Locking screw

5. Display module

6. Battery cover

7. Depth bar

8. Set button

9. Mode button

10. Outside measuring face 

1

2

3

4

5

6

10

7

OPERATING INSTRUCTIONS

1. Switch on the caliper by pressing the mode button (to switch off the caliper press and hold

down the set button).

2. Loosen the locking screw and move the slider to bring the outside faces together and set 

zero by pressing the set button.

3. To select mm or inches, press the mode button three times, ‘unit’ will appear, press the 

set button to toggle between mm and inches then press the mode button to select the 

option you desire. Set zero by pressing the set button.

ABSOLUTE MEASUREMENT (ABS)

1. At the working mode, if ‘ABS’ appears at the bottom of the display screen the caliper will

automatically be in the absolute measurement mode. If ‘REL’ appears, press the mode

button twice, ‘ref’ will appear, press the set button to toggle between REL and ABS then

press the mode button to select the option you desire. 

In ABS mode zero setting will 

not function. 

Set zero by pressing the set button.

RELATIVE MEASUREMENT

1. For taking repeated measurements relative to a proposed zero point.
2. Move the slider to the proposed zero point.
3. At the working mode, if ‘REL’ appears at the bottom of the display screen the caliper will

automatically be in the incremental measurement mode. If ‘ABS’ appears, press the mode

button twice, ‘ref’ will appear, press the set button to toggle between ABS and REL then

press the mode button to select the option you desire. Set zero by pressing the set button.

4. Measurements will now read ± from the chosen relative zero point.

TAKING MEASUREMENTS

External Dimensions

Put the workpiece as close to the reference

surface as possible, and have the measuring

faces firmly in contact with the workpiece 

without excessive force.

Depth Measurement

For depth measurement, set the depth bar

perpendicular to the measured surfaces.

Internal Dimensions

For inside measurement, put the inside 

jaws as deep as possible and have the 

measuring faces firmly in contact with the

workpiece without excessive force.

Step Measurement

For step measurement, have the 

step-measuring-faces firmly in contact 

with the workpiece.

9

8

Отзывы: