Read all steps and guides carefully before installing

and using your new water softener.  Follow all steps

exactly to correctly install.  Failure to follow them

could cause personal injury or property damage.

Reading this manual will also help you to get all the

benefits from your water softener.

p

Your Kenmore

®

Elite Hybrid Water Softener will

reduce hardness minerals from water.  This is meas-

ured in grains per gallon (gpg).  It will also remove

some clear water iron*.  This is measured in parts

per million (ppm).  See the specifications page for

the maximum limit of hardness removal.  It will also

reduce taste and odor in water, and will reduce bar-

ium and radium 226/228 in water (see performance

data sheet for details).

p

A water softener will not improve other water problems

such as acidity or iron other than clear water iron.

p

Do not attempt to use this product to make safe

drinking water from non-potable water sources.  Do

not use the system on microbiologically unsafe water,

or water of unknown quality without adequate disin-

fection before or after the system.

p

Check with your local public works department for

plumbing and sanitation codes.  You must follow

their guides as you install the system.  Follow your

local codes if they differ with guides in this manual.

In Massachusetts, plumbing code 248-CMR 3.00 and

10.00 shall be adhered to.  Consult with a licensed

plumber.

* The capacity to reduce clear water iron is substantiat-

ed by Water Quality Association test data.

p

Use only lead-free solder and flux for all sweat-solder

connections, as required by federal codes, when

installing soldered copper plumbing.

p

Use care when handling the water softener.  Do not

turn upside down or drop.

p

Avoid installing in direct sunlight.  Excessive heat may

cause distortion or other damage to non-metallic parts.

p

This water softener works on water pressures of 20 psi

(minimum) to 125 psi (maximum).  If your house water

pressure is over the maximum, install a pressure reduc-

ing valve in the water supply pipe to the softener.

p

Temperature of the water supply to the softener must be

between 40°F and 100°F.  Do not install on hot water.

p

If installing the water softener outdoors, do not locate

where it will be exposed to wet weather, direct sunlight

or extreme hot or cold temperatures.

p

This water softener works on 28V DC electrical power,

supplied by a direct plug-in power supply (included).

Be sure to use the included power supply and plug it into

a nominal 120V, 60 Hz household outlet that is in a

dry location only, grounded and properly protected by

an overcurrent device such as a circuit breaker or fuse.

p

This water softener has a non-metallic valve system.

Installing it on metal plumbing will break electrical

continuity, which may interrupt grounding for the

home.  You must restore electrical continuity in your

metal plumbing system (See Page 11).

FCC NOTICE

NOTE:

This equipment has been tested and found to

comply with the limits for a Class B digital device, pur-

suant to Part 15 of the FCC Rules.  These limits are

designed to provide reasonable protection against

harmful interference in a residential installation.  This

equipment generates, uses, and can radiate radio fre-

quency energy and, if not installed and used in accor-

dance with the instructions may cause harmful interfer-

ence to radio communications.

However, there is no guarantee that interference will not

occur in a particular installation.  If this equipment does

cause harmful interference to radio or television recep-

tion, which can be determined by turning the equipment

off and on, the user is encouraged to try to correct the

interference by one or more of the following measures:

p

Reorient or relocate the receiving antenna.

p

Increase the separation between the equipment and

receiver.

p

Connect the equipment into an outlet on a circuit

different from that to which the receiver is connected.

p

Consult the dealer or an experienced radio/TV

technician for help.

IMPORTANT:

Changes or modifications not expressly

approved by the party responsible for compliance

could void the user’s authority to operate the equip-

ment.

INDUSTRY CANADA NOTICE

This device complies with Industry Canada Standard

RSS-210.  Operation is subject to the following two con-

ditions: (1) this device may not cause interference, and

(2) this device must accept any interference, including

interference that may cause undesired operation of the

device.

Содержание Elite 625.386200

Страница 1: ...IL 60179 U S A www kenmore com System tested and certified by NSF International against NSF ANSI Standard 42 for the reduction of chlorine taste and odor and Standard 44 for hardness reduction efficiency and the reduction of barium and radium 226 228 and certified to NSF ANSI Standard 372 Este sistema ha sido probado y certificado por NSF International según la norma NSF ANSI 42 para la reducción ...

Страница 2: ... appliance or to instruct the user in correct appliance installation operation and maintenance 3 Service calls to correct appliance installation not performed by Sears authorized service agents or to repair problems with house fuses circuit breakers house wiring and plumbing or gas supply systems resulting from such installation 4 Damage to or failure of this appliance resulting from installation ...

Страница 3: ...ten as you want us whenever you want us þ No lemon guarantee replacement of your covered product if four or more product failures occur within twelve months þ Product replacement if your covered product can t be fixed þ Annual Preventive Maintenance Check at your request no extra charge þ Fast help by phone we call it Rapid Resolution phone support from a Sears representative on all products Think...

Страница 4: ... the softener must be between 40 F and 100 F Do not install on hot water p If installing the water softener outdoors do not locate where it will be exposed to wet weather direct sunlight or extreme hot or cold temperatures p This water softener works on 28V DC electrical power supplied by a direct plug in power supply included Be sure to use the included power supply and plug it into a nominal 120...

Страница 5: ... regenerant brine and water used in its operation This softener has a rated softener efficiency of not less than 3 350 grains of total hardness exchange per pound of salt based on sodium chloride and shall not deliver more salt than its listed rating or be operated at a sustained maximum service flow rate greater than its listed rating This softener has been proven to deliver soft water for at lea...

Страница 6: ...PROPER ORDER TO INSTALL WATER TREATMENT EQUIPMENT Shows sequence of equipment only not all items are needed in all applications Hybrid Water Softener Sediment Cartridge Filter Water Heater Untreated Water to Outside Faucets Hot Water to House Cold Water to House Iron Filter Pressure Tank City Water Supply Well Water Supply Well Pump OR Figure 3 Always locate an Iron Filter UPSTREAM of the Hybrid W...

Страница 7: ...hard water Soft cold water Soft hot water Figure 4 WHERE TO INSTALL THE HYBRID WATER SOFTENER Review the following points before you choose a place to put your softener 1 Place as close as possible to but always downstream from the pressure tank well water or water meter city water 2 Place as close as possible to a water drain such as a floor drain laundry tub sump or standpipe See Fig 4 3 Connect...

Страница 8: ...2 Shut off the gas or electric supply to the water heater 3 Open the highest and lowest water faucets in your house This will let water drain from the pipes Close faucets after water has drained 4 Remove the top cover Pull outward on the two tabs to release top cover see Fig 5 The salt lid remains attached to the top cover when removed Set both covers aside so they will not get scratched or broken...

Страница 9: ...oes to the valve inlet side CAUTION Never solder fittings while connected to nonmetallic parts Wait until soldered pipe has cooled before connection See Fig 10 CAUTION Be careful when putting pipe fittings togeth er Do not cross thread and do not over tighten Figure 10 Incoming Hard Water Main Water Pipe 1 Cut pipe to correct length 2 Solder When cool do step 3 3 Put threaded adaptor into bypass v...

Страница 10: ...copper drain tube to the softener purchase a compression fitting 1 4 female pipe threads x 1 2 O D tube and tubing from your local hardware store CONNECT SALT TANK OVERFLOW HOSE 1 Locate the rubber grommet adaptor elbow and tube clamp see Fig 11 that are in the parts bag 2 Push the grommet into the hole in the salt tank wall so that half is inside and half is outside 3 Push the larger end of the a...

Страница 11: ...nsed down the drain before any water from the softener is directed to the home s faucets or water heater CAUTION To avoid water or air pressure damage to softener inner parts and to flush pipe chips or other residue from the water pipes be sure to do the following steps exactly as instructed 1 Make sure the softener s valve drain hose is hooked up and the open end directed to a floor drain laun dr...

Страница 12: ...til all air is expelled then close 4 Close both cold water faucets 5 Check your plumbing work for leaks and fix right away if any are found Be sure to observe previous caution notes NOTE If this procedure is performed on a new softener water coming from the taps may initially be dis colored This normally occurs the first time water runs through the resin bed The discol ored water is not harmful an...

Страница 13: ...ave detected a problem See Troubleshooting on Page 24 Light on steady not flashing The softener has power applied and does not require any attention CONNECTION STATUS LIGHT Blue When the water softener is connected to electrical power the blue connection status light on the control panel will operate as follows Light flashing slowly The softener is in Connect Mode ready to connect to the Kenmore c...

Страница 14: ... do SET RECHARGE REGENERATION START TIME 1 The softener s default recharge start time is 2 00 AM This is normally a time of day when water is not being used in the household Hard water bypasses the softener if the household draws water during the recharge cycle If a different recharge start time is desired press the r UP or s DOWN buttons to change the time in 1 hour increments Be sure AM or PM is...

Страница 15: ... or s DOWN buttons to set the type of salt you will be using in your water softener The default is NaCl standard Sodium Chloride water sof tener salt If you will be using KCl Potassium Chloride instead be sure to set salt type to KCl This setting adjusts the regeneration cycle times to com pensate for the different rate at which KCl dissolves See also Page 16 for more information on salt types 2 W...

Страница 16: ... bread Persons who are concerned about their drinking water should consider a Kenmore reverse osmosis drinking water system that will remove in excess of 90 of the sodium and other drinking water contaminants WATER SOFTENING SALT WITH IRON REMOVING ADDITIVES Some salts have an additive to help the softener handle iron in the water supply These salts may be used if your water supply has a high iron...

Страница 17: ...h for 5 minutes indicating it is ready to connect If the blue light stops flashing before you are ready to connect press and hold the CONNECT SMART button for 5 seconds The blue light will begin flash ing for 5 minutes allowing the connection process to take place 2 Standing in front of the water softener open the Kenmore Smart app 3 Follow the instructions to create a new account with your prefer...

Страница 18: ... guests visiting and you may run out of soft water before the next automatic regeneration You did not add salt to the softener before it ran out Add salt to the softener before regenerating You can start a regeneration immediately or you can set the controller to regenerate at the next preset recharge time 2 00 AM or as set RECHARGE NOW Press the REGENERATION button and hold for 3 sec onds until t...

Страница 19: ...m rated capacity while most often achieving maximum salt efficiencies When installing this unit in the State of California you MUST turn the efficiency feature ON The softener may initiate more frequent recharges but it will operate at 4000 grains per pound of salt or higher Efficiency Icon LEVEL SALT Figure 27 press for tonight hold for immediate Salt Level Set Figure 26 3 Press the SET SALT LEVE...

Страница 20: ...ra backwash cycle automatically is set to 7 minutes However you can adjust this time from 1 to 15 minutes in length To change this cycle time use the r UP but ton to increase the time or the s DOWN button to shorten the time If no change is desired continue to next step Figure 32 Figure 31 4 Press SELECT again to display the 97 screen 97 FEATURE The 97 Feature can save salt and water by regenerati...

Страница 21: ... is desired continue to next step Controller Features 8 Press SELECT again to display the Backwash Time setting screen Figure 35 BACKWASH FAST RINSE TIMES If you experience salty tasting water after regeneration you may need to increase the backwash and fast rinse times The default backwash time is 14 minutes and the default fast rinse time is 6 minutes However you may increase or decrease the bac...

Страница 22: ... dis play is blank but the electronic controller keeps the cor rect time for several hours When electrical power comes on again you will have to reset the present time only if the display is flashing The HARDNESS and RECHARGE TIME never require resetting unless a change is desired Even if the clock is incorrect after a long power outage the softener works as it should to keep your water soft howev...

Страница 23: ...pty Space Water Level 1 2 Pencil Mark Broom Handle Push tool into salt bridge to break Service Information ALWAYS MAKE THESE INITIAL CHECKS FIRST 1 Does the time display show the correct time of day If display is blank check power source to the sof tener If time is flashing power was off for a long peri od The softener resumes normal operation but regenerations occur at the wrong time If an error ...

Страница 24: ...y kinks sharp bends or any water flow blockage See Valve Drain Requirements Intermittent hard water Incorrect time set Check and change time setting Incorrect water hardness set Refer to Set Water Hardness Number to set correctly Hot water being used when softener is regenerating Avoid using hot water while the softener is regenerating as the water heater will fill with hard water Possible increas...

Страница 25: ...play when setting times or hardness the normal time of day dis play automatically returns if a button has not been pressed for 4 minutes To return to the diagnostic display repeat step 1 above TURBINE OPERATION If no water is flowing through the softener the turbine indicator displays three zeros When water is flowing a 000 to 199 count repeats for each gallon of water passing through the turbine ...

Страница 26: ...ain will begin Verify brine draw from the brine tank by shining a flashlight into the brinewell and observing a noticeable drop in the liq uid level 5 If the softener does not draw brine nozzle and or venturi dirty nozzle and venturi not seated properly on gasket restricted drain check drain fitting and hose ineffective nozzle and venturi seal other inner valve problem rotor seal rotor disc wave w...

Страница 27: ...oftener to Connect Mode 1 Press the CONNECT SMART button and hold for 5 seconds 2 The blue connection status light should begin flash ing indicating that the unit is in Connect Mode awaiting connection 3 Connect the system to the Kenmore cloud as described on page 17 3 Press the SELECT button and the electronic controller will restart 4 Set the present time hardness etc as described on pages 14 15...

Страница 28: ... View Kenmore Model No 625 386200 Valve Assembly See Pages 30 31 for parts 1 23 Rating Decal Location 15 16 22 24 25 28 20 19 21 27 26 29 30 17 18 2 4 7 8 9 11 10 12 13 14 3 6 5 Questions Call the Kenmore Water Line 1 800 426 9345 28 ...

Страница 29: ...65 Salt Storage Tank 7327576 Brinewell Mounting Hardware Kit includes Key Nos 16 17 16 á Screw 1 4 20 x 5 8 17 á Wing Nut 1 4 20 Key No Part No Description 18 7214375 Brinewell Assembly including salt level decal 7331258 Overflow Hose Adaptor Kit includes Key Nos 19 21 19 á Adaptor Elbow 20 á Grommet 21 á Hose Clamp 22 7155115 Brinewell Cover 23 7325396 Rim 7331177 Tank Neck Clamp Kit includes 2 e...

Страница 30: ...d View Cross Section View 91 50 51 52 53 54 55 56 57 58 59 60 66 61 67 62 63 70 64 68 69 65 71 72 73 74 75 76 77 79 78 Seal Wear Strip 80 81 82 83 84 85 86 87 88 89 90 Questions Call the Kenmore Water Line 1 800 426 9345 30 ...

Страница 31: ...ss Valve Assembly 3 4 in cluding 2 O Rings See Key No 72 7139999 Drain Tubing 3 8 I D x 20 ft 7123613 Silicone Grease for O Rings Ù 42 34405 Flexible Connectors 3 4 Ù 42 34407 Flexible Connectors 1 Ù Key No Part No Description 50 7338111 Screw 6 19 x 1 3 8 2 req 51 7281291 Motor 52 7337474 Motor Mount 53 7284964 Cam Gear 54 7030713 Switch 7331185 Drain Hose Adaptor Kit incl Key Nos 55 59 55 á Clip...

Страница 32: ...44 553 6667 www kenmore com In Canada 1 800 469 4663 www sears ca Call anytime for the location of your nearest Sears Parts Repair Service Center 1 800 488 1222 U S A 1 800 469 4663 Canada To purchase a protection agreement on a serviceable product 1 800 827 6655 U S A 1 800 361 6665 Canada Para pedir servicio de reparación a domicilio y ordenar piezas 1 888 SU HOGAR 1 888 784 6427 www kenmore com...