background image

Содержание ECONOMIZER 6 153.333315 HA

Страница 1: ... necesita el manual instructive y o etiquetas en espa _ol puede obtenerlos Ilamando al 1 800 821 2017 NO TRATE DE INSTALAR O OPERAR ESTE CALENTADOR DE AGUA si no entiende la informaci6o eo las etiquetas o en el manual instructive No hacer case de esta advertencia podria resultar en la MU ERTE O GRAVES LESION ES CORPORALES WARNING If the information in these instructions is not followed exactly a f...

Страница 2: ...WARNING indicates a potentially hazardous situation which if not avoided could result in death or injury CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided could result in property damage All safety messages will generally tell y...

Страница 3: ...on rating plate Maintain required clearances to combustibles Keep ignition sources away from faucets after _ extended period of non use _ Read instruction manual before installing using or servicing water heater Explosion Hazard Overheated water can cause water tank explosion Breathing Hazard Carbon Monoxide Gas Properly sized temperature and pressure relief valve must be installed in opening prov...

Страница 4: ... Heater 14 Venting 14 15 Gas Piping 15 16 Sediment Trap 16 17 OPERATING INSTRUCTIONS 18 19 Lighting Operating Label 18 Temperature Regulation 19 SERVICE AND ADJUSTMENT 20 22 Tank Sediment Cleaning 20 Venting System Inspection 20 Burner Inspection 20 Burner Cleaning 20 Housekeeping 20 21 Anode Rod Inspection 21 Temperature Pressure Relief Valve Operation 21 Draining 21 22 Drain Valve Washer Replace...

Страница 5: ...d States The National Fuel Gas Code ANSI Z223 1 NFPA 54 This publication is available from the Canadian Standards Association 8501 East Pleasant Valley Rd Cleveland Ohio 44131 or The National Fire Protection Association 1 Batterymarch Park Quincy MA 02269 If after reading this manual you have any questions or do not understand any portion of the instructions call the Sears Service Center Carefully...

Страница 6: ...ANSION TANKS FOR THERMAL EXPANSION CON DmONS AVAILABLE IN 2 GALLONS 7 6 LITERS AND 5 GALLONS 18 9 LITERS CAPACITY THROUGH LOCAL SEARS STORE OR SERVICE CENTER Basic Tools You may or may not need all these tools depending on your type of installation These tools can be purchased at your local Sears Store Pipe Wrenches 2 14 356 ram _r_ Screwdriver Tin Snips 6 1 82 m Tape or Folding Ruler Garden Hose ...

Страница 7: ...n Burner W Flue X Drain Pan Y Thermostat Shield optional Z Piezo Ignitor AA Air Intake Screen INSTALL IN ACCORDANCE WITH LOCAL CODES DRIP LEG AS REQUIRED BY LOCAL CODES TO VENT TERMINATION ON ROOF INSTALL THERMAL EXPANSION TANK IF WATER HEATER IS INSTALLED IN A CLOSED WATER SYSTEM B S W V VACUUM RELIEF VALVE _ N_TALLPER LOCALCODE5 Q Y AA ALL PIPINGMATERIALS TO BE SUPPLIEDBY CUSTOMERS FIGURE1 7 T T...

Страница 8: ...n most installations the vent pipe can be lifted off after any screw or other attached devices are removed Dispose of the draft hood The new water heater has a draft hood which must be used for proper operation Q If you have copper piping to the water heater the two copper water pipes can be cut with a hacksaw approximately four inches away from where they connect to the water heater see Figure 6 ...

Страница 9: ...ther open flame or spark producing appliance Also the water heater must be located and or protected so it is not subject to physical damage by a moving vehicle I _ Fire Hazard For continued protection against risk of fire Do not instalJ water heater on carpeted floor Do not operate water heater if i flood damaged This water heater must not be installed directly on carpeting Carpeting must be prote...

Страница 10: ...unnecessary Breathing Hazard Carbon Monoxide Gas _ z _ Do not obstruct water heater air _ _ intake with insulating blanket i_i _i Gas and carbon monoxide _ _ i i_ _ detectors are available _ _ Install water heater in accordance _ _ with the instruction manual Breathing carbon monoxide can cause brain damage or death Always read and understand instruction manual _b WARNING Should you choose to appl...

Страница 11: ...opening shall have a minimum free area of 1 square inch per 4 000 Btu per hour 5 5 cm2 kW of total input ratingof all equipment in the enclosure see Figure 12 When communicating with the outdoors through vertical ducts each opening shall have a minimum free area of 1 square inch per 4 000 BTU per hour 5 5 cm2 kW of total input rating of all equipment in the enclosure see Figure 12 VENTILATION LOUV...

Страница 12: ...ose used for boiler treatment shall not be introduced into this system Water supply systems may because of such events as high line pressure frequent cut offs or the effects of water hammer among others have installed devices such as pressure reducing valves check valves back flow preventers etc to control these types of problems When these devices are not equipped with an internal by pass and no ...

Страница 13: ...pressure not to exceed the marked hydrostatic working pressure of the water heater 150 psi 1 035kPa and a discharge capacity not less than the water heater input rate as shown on the model rating plate For safe operation of the water heater the relief valve must not be removed from its designated opening nor plugged The temperature pressure relief valve must be installed directly into the fitting ...

Страница 14: ...e water heater is in use To insure complete filling of the tank allow air to exit by opening the nearest hot water faucet Allow water to run until a constant flow is obtained This will let air out of the water heater and the piping Check all water piping and connections for leaks Repair as needed Venting Breathing Hazard Carbon Monoxide Gas Vent dampers must be certified ir_accordance with ANSI Z2...

Страница 15: ... joint with sheet metal screws There must be a minimum of 6 inches 153 ram clearance between single wall vent pipe and any combustible material Fill and seal any clearance between single wall vent pipe and combustible material with mortar mix cement or other noncombustible substance For other than single wall follow vent pipe manufacturer s clearance specifications To insure a tight fit of the ven...

Страница 16: ...iance in operation The appliance and its individual Shut off valve shall be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 pound per square inch 3 5kPa It shall be isolated from the gas supply piping system by closing its individual manual Shut off valve during any pressure testing of the gas supply piping system at test...

Страница 17: ...ter installation The sediment trap shall be either a tee fitting with a capped nipple in the bottom outlet or other device recognized as an effective sediment trap If a tee fitting is used it shall be installed in conformance with one of the methods of installation shown in Figures 19 and 20 GROUNOJOII_T _ _ BLA K PIPE UNION BLACK PIPE OPTIONAL GAS CONTROL VALVE 3 MIN 76 2 n CAP FIGURE 20 GAS PIPI...

Страница 18: ...ILOT to OFF unless it is pushed down slightly Do not force 4 Remove the outer burner door located below the gas control 5 Wait five 5 minutes to clear out any gas If you then smell gas _ STOP Follow B in the safety information above on this label Ifyou don t smell gas goto next step 6 This unit is equipped with a push button pilot ignitor which is used to light the pilot Locate the ignitor on the ...

Страница 19: ...ap then you must take special precautions In addition to using the lowest possible temperature setting that satisfies your hot water needs a means such as a mixing valve shall be used at the hot water taps used by these people or at the water heater Mixing valves are available at plumbing supply or hardware stores Follow manufacturer s instructions for installation of the valves Before changing th...

Страница 20: ... or Explosion Hazard At least once a year a visual inspection should be made of the venting system You should look for Obstructions which could cause improper venting The combustion and ventilation air flow must not be obstructed Damage or deterioration which could cause improper venting or leakage of combustion products Rusted flakes around top of water heaten Be sure the vent piping is properly ...

Страница 21: ... Figure 24 TEMPERATURE PRESSURE DISCHARGE PIPE FIGURE 24 If after manually operating the valve it fails to completely reset and continues to release water immediately close the cold water inlet to the water heater follow the draining instructions and replace the temperature pressure relief valve with a new one If the temperature pressure relief valve on the appliance weeps or discharges periodical...

Страница 22: ... Turn OFF gas supply to water heater 2 Follow Draining instructions 3 Turning counter clockwise t_ remove the hex cap below the screw handle 4 Remove the washer and put the new one in place 5 Screw the handle and cap assembly back into the drain valve and retighten using a wrench DO NOT OVER TIGHTEN 6 Follow instructions in the Filling The Water Heater section 7 Check for leaks 8 Follow the lighti...

Страница 23: ...ble from Sears stores and through the Sears Service Centers Contact the local plumbing inspector water supplier and or the Sears Service Center for assistance in controlling these situations see Figure 26 Thermal Expansion Tank Specifications Tank Dimensions Pipe Model Capacity in Inches Fitting Number In Gallons Diameter Len_lth On Tank 153 331020 2 8 203mm 12 3 4 323mm 3 4 Male 153 331050 5 11 2...

Страница 24: ...ads If the smelly water persists after the anode replacement and chlorination treatment we can only suggest that chlorination or aeration of the water supply be considered to eliminate the water problem Do not remove the anode leaving the tank unprotected By doing so all warranty on the water heater tank is voided AIR In Hot Water Faucets Explosion Hazard Flammable hydrogen gases may be present Ke...

Страница 25: ...from temperature pressure relief valve may be due to thermal expansion or high water pressure in your area E The temperature pressure relief valve may be leaking at the tank fitting R Water from a drain valve may be due to the valve being slightly opened G The drain valve may be leaking at the tank fitting H Combustion products contain water vapor which can condense on the cooler surfaces of the t...

Страница 26: ...ures High temperature limit switch activated WATER TOO HOT Thermostat set too high WATER HEATERSOUNDS Condensation dripping on burner SIZZLING RUMBLING Sediment or calcium in bottom of heater tank SOOTING Improper combustion VENTGASODORS Lack of supply air Impropedy installed vent piping Downdraft Poor combustion Tighten threaded connections Inspect other appliances near water heater Refer to COND...

Страница 27: ...2 N_ Shown lncludeslnoerDoorGasket 9003446 9003446 9003446 9003446 9003446 9003406 9003406 9003406 9003406 9003406 9003513 9003513 9003514 9003514 9003514 F145 1278 F145 1278 F145 1278 F145 1278 F145 1278 F145 1280 F145 1280 F145 1280 F145 1280 F145 1280 9003448 9003448 9003448 9003448 9003448 9001584 9001584 9001584 9001584 9001584 9003545 9003545 9003545 9003545 9003545 9003410 9003410 9003410 9...

Страница 28: ...ns Rental reimbursement if repair of your covered product takes longerthan promised Once you purchase the Agreement a simple phone call is all that it takes for you to schedule service You can call anytime day or night or schedule a service appointment on line Sears has over 12 000 professional repair specialists who have access to over 4 5 million quality parts and accessories That s the kind of ...

Отзывы: