9-7 Poor cooling in Freezer compratment
No
1
Checking flow
Check the sensor resistance.
2
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
3
Check if cold air blows from air vents with
your hand.
※
The sensor is determined by
the temperature.
For example, 23
㏀
indicates -4°F.
Result & SVC Action
<CON7>
Status
Windy
No windy
SVC Action
Go to the 4
Check the F Fan motor
4
Check the air temperature.
Cold or not ?
Status
Cold
Not cold
SVC Action
Explain to customer
Check the Compressor
And sealed system
(1) To (2)
-22°F
/ -30
°C
-13°F
/ -25
°C
-4°F
/ -20
°C
5°F
/ -15
°C
14°F
/ -10
°C
23°F
/ -5
°C
32°F
/ 0
°C
Result
40
㏀
30
㏀
23
㏀
17
㏀
13
㏀
10
㏀
8
㏀