- 37 -
9-6 Poor cooling in Refrigerator room
No
1
Checking flow
Check R-Sensor resistance.
2
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
3
Open the fresh food door and Check the
air flow.
※
R-Sensor is determined by
the temperature.
For example, 30
㏀
indicates 32°F.
Result & SVC Action
Temperature
23°F
/ -5
°C
32°F
/ 0
°C
41°F
/ 5
°C
50°F
/ 10
°C
59°F
/ 15
°C
Result
38
㏀
30
㏀
24
㏀
19.5
㏀
16
㏀
Status
Windy
No windy
SVC Action
Go to the 4
Check the F Fan motor
Check the Damper
(Go to the 5)
4
Check the air temperature.
Cold or not ?
Status
Cold
Not cold
SVC Action
Explain to customer
Check the Compressor
And sealed system
<CON7>