- 33 -
9-2 Cube mode doesn’t work
No
1
2
Checking flow
Check the loose connection on the
Dispenser PCB
Check the Skyblue to White on the Dispenser
PCB (While pushing the Pad S/W)
Result & SVC Action
<CON2>
3
Check the RED to White Red.
(While pushing the Pad S/W)
4
Check the resistance value.
<CON1>
<CON3>
<Ice Maker>
<AC Indoor Motor>
<Dispenser Motor>
(2)
(1)
(3)
(4)
(1) to (2)
(3) to (4)
31.1 ~ 42.1
Ω
Other
9.9 ~ 12.1
Ω
Other
Explain
Replace
Geared Motor
Explain
Replace
Geared Motor
Point
Result
SVC Action
Pushing
Not
pushing
112 ~ 115 V
Other
0 ~2 V
Other
Go to the 3
Change
Dispenser PCB
Go to the 3
Change
Dispenser PCB
Ice Button
Result
SVC Action
Pushing
Not
pushing
9 ~ 12 V
Other
0 ~2 V
Other
Go to the 4
Change
Dispenser PCB
Go to the 4
Change
Dispenser PCB
Ice Button
Result
SVC Action
Appliantology.org