REFRIGERATOR INSTALLATION
Removing the left (freezer) door with water line
connection.
•
Pull up the water feed tube while pressing area
(Figure 1) as shown in the figure below.
If a tube end is deformed or abraded, trim the
part away. Disconnecting the tube under the door
causes about 0.13 gallons (0.5 liters) water to flow out.
container at end of tube to prevent water
onto the floor.
•
NOTE:
Put a large
from draining
Figure 1
1. Open the door. Remove the top hinge cover screw (1).
2. Use a flat blade screwdriver to pry back the hooks
(not shown) on the cabinet underside of the cover (2).
Lift up the cover.
3. Disconnect all the wire harnesses (3).
4. Remove the grounding screw (4).
5. Rotate hinge lever (5) counterclockwise
. Lift the top
C
A
U
T
I
O
N
:
When lifting the hinge free of the latch,
be careful that the door does not fall forward.
7. Place the door, inside facing up, on a nonscratching
surface.
6.
being careful to
Lift the door from the lower hinge pin
pull the water lines through the lower hinge pin.
hinge (6) free of the hinge lever latch (7).
(1)
(2)
(3)
(5)
(6)
(7)
(4)
Type 2
Type 1
(6)
(5)
Rivet
NOTE
: Regardless of hinge lever type, removal process is
the same.
(7)
Reinstalling the right (refrigerator) door
2. Fit top hinge (4) over hinge lever latch (5) into
place. Rotate lever (3) counterclockwise to secure
3. Hook tab on switch side of corner under edge of wire
opening in cabinet top. Position cover (2) into place.
Insert and tighten cover screw (1).
hinge.
1. Place the door onto the lower hinge pin.
(1)
(2)
(3)
(4)
(5)
NOTE
: Regardless of hinge lever type, installation process
is the same.
Type 2
Type 1
(3)
(4)
(5)
Rivet
2. Fit top hinge (6) over hinge lever latch (7) and into
place. Rotate lever (5) clockwise to secure hinge
3. Install the grounding screw (4) and connect all the
wire harnesses (3).
4. Hook tab on door switch side of cover (2) under edge
of wire opening in cabinet top. Position cover into
place. Insert and tighten cover screw (1).
1. Feed the water tubes through the lower hinge pin and
place the door onto the lower hinge pin.
Reinstalling the left (freezer) door
(1)
(2)
(3)
(5)
(6)
(7)
(4)
5. Reconnect the water tubes by inserting the tubes into
the connectors.
NOTE
: Regardless of hinge lever type, installation process
is the same.
Type 2
Type 1
(5)
(6)
(7)
Rivet
Insert Line
Tube
Collet