background image

Содержание 79044272000

Страница 1: ...cted surface The corners of this unit are fragile Carefully install the cooktop by its sides When instaliing_ never let the weight of the unit rest on any one corner Cooktop Cutout Dimensions G 4 X 8 10 2 cm x 20 3 cm opening at the right rear to route armored cable if a panel is present F Figure 1 30 Model shown only 30 Ceramic Model 303 78 1 211 2 54 6 51 2 14 3V4 8 3 29 73 7 191 2 49 5 36 Ceram...

Страница 2: ...op F Approximate Location of Junction Box I 12 30 5 cm 71 2 19 1 cm Min From Edge of Cooktop to Nearest Combustible Wall Either Side of Unit It is not recommended to use drawer underneath cooktop Empty space is needed for installation purpose Letters on this figure refer to chart on front page except for J To eliminate the risk of burns or fire by reaching over heated surfaces cabinet storage spac...

Страница 3: ...ed as shown in Figure 2 with as much slack as possible remaining in the cable between the box and the appliance so it can be moved if servicing is ever necessary 3 A suitable strain relief must be provided to attach the flexible armored cable to the junction box Observe aH governing codes and local ordinances Unpacking Instructions 1 Leave corner supports on cooktop until completion of Electrical ...

Страница 4: ... other and use ground lead to ground unit in accordance with local codes connect neutral lead to branch clrcult neutral conductor in usual manner see Figure 6 or 7 If your appliance is to be connected to a 3 wire grounded junction box US only where local code permit connecting the appllance groundlng conductor to the neutral white see Figure 4 or 5 NOTE TO ELECTRICIAN The armored cable leads suppl...

Страница 5: ...le from Power Supply White Wire Black Wires Junction Box Ground Wire U L Listed Conduit Bare or Green Wire Connector or CSA listed Cable from appliance Figure 6 4 WIRE GROUNDED JUNCTION BOX if your cooktop has a 4 wire cable see figure 7 1 Disconnect the power supply 2 Separate the green or bare copper and white appliance cable wires 3 In the circuit breaker fuse box or junction box connect applia...

Страница 6: ... heat damage or fire see Figure 10 2 Nylon spacers _JJ__The corners of this unit are fragile Carefully install the cooktop by its sides When installing never let the weight of the unit rest on any one corner Checking Operation Refer to the Use and Care Guide for operation Do not touch cooktop glass or elements They may be hot enough to burn you Model and Serial Number Location The serial plate is ...

Страница 7: ...able from cooktop to junction box Approx 3 _ 208 240Volt 7 5cm _ junction box for cooktop Cabinet side fliier panels are necessary to isolate the unit from adjoining cabinets Cabinet side filler height should allow for installation of ap proved cooktop models 36 Min 91 4cm Min Unit will overlap minimum edges by 1 2 5cm Use 3 4 1 9cm plywood installed on two runners flush with toe plate Base must b...

Страница 8: ...Notes 8 ...

Страница 9: ... son de 30 76 2 cm 30 76 2 cm rain para un cjabinete desprotegido 24 61 cm rain para una superficie protegida Las esquinas de esta unidad son fr6giles Cuidadosamente instaie la estufa sujet6ndola por los iados Ai instalaria nunca deje que el peso del aparato se recargue sobre una soia esquina Dimensiones del Recortado de la Estufa 4 1 x 8 10 2 cm x 20 3 cm apertura en la parte posterior derecha pa...

Страница 10: ...cercano 10 sobre la parte superior 25 4 cm deJ armario F 12 w 30 5 cm Ubicaci6n aproximada de la caja de empaimes _ro dei corte hasta ei borde delantero de ia parte superior dei armario 71 2 19 1 cm min desde el borde del hasta ei compartimiento de combustible ambos iados del artefacto No es recomendabie utilizar cajones debajo de ia estufa Para ias dimensiones F G H vSase ia tabia en ia p6gina 1 ...

Страница 11: ...na alargadora para enchufar este electrodom_silco Esto podria resultar en un incendlo un choque el_ctrlco u otto tipo de da_o personal 2 Este electrodom_stico debe conectarse a ia caja de fusibles o de cortacircuitos _ por media de un cable biindado flexible o un cable con forro no met6iico EI cable blindado flexible que va desde ei electrodomSstico debe de estar conectado directamente a ia caja d...

Страница 12: ...ales o donde los c6dlgos locales no permltan poner a tlerra medlante el neutro blanco o en Canad6 desconectar la conexi6n blanca de la verde V utillzar la conexi6n a tlerra para poner a tlerra la unldad de acuerdo a los c6dlgos locales conectar el neutro al clrculto de blfurcaci6n conductor neutro de manera usual Vet Figura 6 o 7 St su electrodom stlco va a set conectado a una caja de conexi6n pue...

Страница 13: ...interruptor autom6fico caja de fusibles o caja de juntas conectar el aparato y los cables residen dales como se muestra en la figura 6 Cable desde el suministro de energ a Alambre desnudo _Alambre blanco Si su cocina tiene un cable de 4 hilos ver figura 7 1 Desconecte el suministro el_ctrico 2 Separe el aJambre verde o cobre desnudo y eJ alambre blanco del electrodom6stico 4 En el interruptor auto...

Страница 14: ...las de_ _ Z_ k _ sostenimiento z _ Figura 10 Las esquinas de esta unidad son fr6giies Cuidadosamente instaie la estufa sujet6ndola par los lados AI instalarla nunca deje que el peso del aparato se recarcjue sobre una sola esquina Revisi6n de operaci6n Consuite ei Manual del Usuarlo para ias instrucciones de funcionamiento No toque ei cristai o los elementos de ia estufa Puede que estSn io suficien...

Страница 15: ...10 2 cm para cjuiar el cable blindado de la cubierta a la caja de conexiones Approx 3 208 240V caja de empalme para ia estufa ei_ctrica Los paneies de relleno iateraJes dei gabinete son necesarios para aislar la unidad de los gabinetes adyacentes La aitura del relleno lateral del gabinete debe permitir la instalaci6n de modelos de tapas de cocina aprobados 36 Min 91 4 cm Min Carte minima hasta que...

Страница 16: ...Notas 16 ...

Отзывы: