7-25
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Setting time
does not count
down when
touching START
pad.
2. Fan motor or
oven lamp do
not turn on.
No continuity.
Continuity.
Continuity
Defective PCB
assembly.
Loose connection.
Replace PCB
assembly.
Connect them
tightly.
No continuity
Abnormal
Check fan motor.
Defective fan motor.
Replace fan motor.
Abnormal
Normal
Check oven lamp.
Defective oven lamp.
Replace oven lamp.
Defective
secondary switch.
Replace
secondary switch.
Check continuity
of secondary
switch (with
door closed).
Check the con-
nection between
CN1 connector
and PCB
assembly.
(TROUBLE 3) Display shows all figures set, but oven does not start cooking while desired
program times are set and START pad is touched.
3. The display
shows F-9.
No continuity.
Continuity.
Loose connection.
Connect them
tightly.
Check the
connection between
magnetron, control
PCB and inverter
module.
Abnormal
Normal
Defective Relay2.
Replace PCB
assembly.
Check the Relay 2 of
PCB assembly.
Check the
inverter module.
Abnormal
Normal
Defective inverter
module.
Replace inverter
module.
Check the
Magnetron.
Abnormal
Defective
Magnetron.
Replace
Magnetron.
Normal
Check the power
source voltage.
Abnormal
Unsafe AC input
voltage.
Suggest customer
contact local electric
power utility co. or
qualified electrician.
Содержание 721.63682
Страница 9: ...5 1 SCHEMATIC DIAGRAM OVERALL CIRCUIT DIAGRAM ...
Страница 41: ...8 4 LATCH BOARD PARTS 4000 W111 4001 4002 4003 4002 4004 EV ...
Страница 44: ...8 7 INSTALLATION PARTS EV 6008 6009 6010 6011 ...
Страница 45: ...8 16 SCHEMATIC DIAGRAM OF P C B ...
Страница 46: ...8 17 PRINTED CIRCUIT BOARD ...
Страница 47: ...P NO 3828W5S2629 Printed in Korea ...