14
5. Disassembly and Reassembly
5-2 Replacement of Magnetron
Parts
Explaination Photo
Explaination
Magnetron
Remove the magnetron including the shield
case, permanent magnet, choke coils and
capacitors (all of which are contained in one
assembly) .
1.
Disconnect all lead wires from the
magnetron .
2.
Remove nuts (2) securing the magnetron
to the wave guide .
3.
Take out the magnetron very carefully .
NOTE1:
When removing the magnetron, make sure that it antenna does not hit any adjacentparts, or it may be
damaged .
NOTE2:
When replacing the magnetron, be sure to remount the magnetron gasket in the correct position and make
sure the gasket is in good condition .
NOTE3:
Reconnect the lead wire to thermal cutout mounted on the magnetron, before replace the magnetron .
PRECAUTION
During replacement, be certain R .F . anode gasket is in place around anode stub .
PERFORM MICROWAVE LEAKAGE TEST
Содержание 401.85052010
Страница 3: ...3 1 Precaution ...
Страница 8: ...8 3 Operating Instructions 3 1 Control Panel ...
Страница 47: ...47 9 PCB Diagrams 9 1 PCB Diagrams ...
Страница 49: ...49 10 Wiring Diagrams 10 1 Wiring Diagrams ...
Страница 50: ...50 10 Wiring Diagrams 10 2 Wiring Diagrams ...