1
KENMORE ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
All dimensions are stated in inches and (cm).
Allow 2" (5 cm) space below the armoured cable opening to clear the electric cable and
allow space for installation of the junction box on the wall at the back of the cooktop.
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
IMPORTANT INSTALLATION INFORMATION
• All electric cooktops run off a single phase, three-wire or four-wire cable, 240/208 volt, 60 hertz, AC only
electrical supply with ground.
• Minimum distance between cooktop and overhead cabinetry is 30" (76.2 cm).
WARNING
Figure 1
P/N 318201438 (0603) Rev. A
A
B
C
E
F
G
H***
D
Cooktop Dimensions
* 30" (76.2 cm) min. for
unprotected cabinet and
24" (61 cm) min. for
cabinet with protected
bottom surface.
Cooktop Cutout Dimensions
30" Min. *
(76.2 cm)
For Standard Installation:
35 1/8"
(89.2 cm)
1" (2.5 cm)
4"X 8" (10.2 cm x 20.3 cm)
opening to route armoured cable.
7¼"
(18.4 cm)
**Note: D
&
E
are critical to the proper installation
of the cooktop.
D
reflects the finished dimension.
Due to the variation in countertop materials, it is
recommended to first undercut this dimension, and
then adjust it upon installation of the cooktop.
Do not slide unit into cabinet cutout.
Protruding screws on the bottom of
unit may damage the bottom front
finish.
CUTOUT DIMENSIONS
H. DEPTH BELOW
MODEL
A. LENGTH
B. WIDTH
C. DEPTH
LENGTH
WIDTH
COOKTOP
D**
E**
F
G
36 (91.4 )
35
7
/
8
(91.1)
25 (63.5)
7¾ (19.7)
35
15
/
16
(91.3) 35
3
/
16
(89.4)
22 (55.9) 1
1
/
8
(2.9) Max.
7
1
/
2
(19.1)
Printed in United States