If the unit is to be placed outside of the room to be cooled, you should try to position the unit on a 

flat solid surface and in an area protected from rain and sun exposure such as sunroom, veranda 
or hallway. You should not operate the unit in moist areas, such as e.g. saunas or similar areas. 

 

The colour of the unit can change slightly due to direct solar radiation. 

 

The unit is equipped with a special thermal deactivation. This protects the unit from overheating in 

extreme ambient conditions. 

 

Please place the unit so that the air inlet is not impeded, e.g. by furniture or curtains, since this can 

negatively effect the capacity. 

 
Place the unit in the shade if possible and in a cool place in order to increase efficiency and to avoid 

overheating. If the ambient temperature is over 32°C the unit may shut down. If this occurs repeatedly, we 
recommend moving the unit to a cooler location out of direct sunlight. 

 
RECIEVER INSTALLATION 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

 

 
To enable operation of the remote control while the machine is not in the room being cooled, you must install 

the remote sensor that came with the unit.  The remote sensor is placed in the window kit. 

 

1)  Remove the plastic cover from the small hole in the window kit.  Keep it for later use. 
2)  Position the remote sensor from the rear of the window kit (outside the room being cooled), by pushing it 

into the hole.  The sensor must face the room being cooled and be positioned above the air outlet. 

3)  Remove the plastic cover from the remote sensor jack on the main body of the unit, found near the top 

of the front of the unit.  Keep it for later use. 

4)  Attach the end of the supplied cable to the jack on the main unit.  Organize the wire so it will not get 

damaged, stepped on or pinched. 

 
When using the remote to control the unit, point the remote to the receiver installed on the window kit, when 
the remote signal received by the main unit, a green LED on the receiver will flash. DO NOT BLOCK THE 

RECEIVER, THE ROOM TEMPERATURE SENSOR IS ALSO IN THIS RECEIVER. 

Set the function to “COOLING“. The target temperature can range between 17°C and 30°C (65°F and 
90°F). 

Make sure that no warm outside air can enter the room. You can also control the unit from inside using the 
remote control, aimed at the sensor on the window kit. 

 

HEATING MODE ***

UNIT MUST BE USED IN ROOM FOR HEAT MODE

*** 

 

On cold days it is recommendable to start the unit early in order to get a warm room. 

 
The heating function of the unit must not be operated at a room temperature less than 15°C. 

 
Disassemble the subassembly of outlet and the subassembly of exhaust pipe as arrow direction Fig.01 and 

then exchange the two subassemblies to install. The finished illustration is as Fig.03.

  

Connect the air hose and the air outlet grid to the unit as displayed in the illustration. The hose must be 

connected to the side with the COOL icon [

]. 

Содержание 35132

Страница 1: ...1 Kenmore 12 000 BTU Portable Air Conditioner Dehumidifier Heater with Remote Control Use Care Guide Model 35132 FOR HOUSEHOLD USE ONLY ...

Страница 2: ...ause circuit failure Changing the outlet without making the appropriate wiring changes will create an unsafe condition that could result in fire or electrical shock Refer all such work to a licensed and qualified electrician WARNING This appliance must be properly grounded The power cord of this appliance is equipped with a three prong LCDI plug To minimize the risk of electric shock use the plug ...

Страница 3: ...ed period of time could be hazardous to your health Do not use this air conditioner for non specified refrigeration purposes e g preserving precision devices food pets plants and art objects Such usage could cause damages to them Due to the possibility of oxygen deficiency ventilate the room when used together with stoves or other heating devices The air conditioner is a consumer comfort appliance...

Страница 4: ...king carton It is recommended to keep the carton and packing material for storage or transportation of the unit Hose Drain hose For continuous drainage Remote sensor kit used only in out of room cooling mode Window slider kit 3pcs 2 AAA batteries Remote Control PARTS OF THE AIR CONDITIONER ACCESSORIES UNPACKING INSTRUCTIONS Figure 1 Figure 2 Front of Unit Figure 1 1 Control panel 2 Remote receiver...

Страница 5: ... the wall or other obstacles such as furniture The plug should be easily accessed after the appliance is positioned 3 If the unit is to be placed outside of the room to be cooled you should try to position the unit on a flat solid surface and in an area protected from rain and sun exposure such as sunroom veranda or hallway You should not operate the unit in moist areas such as e g saunas or simil...

Страница 6: ... TEST and the other is marked RESET Press the TEST button you will hear a click as the RESET button pops out 3 Press the RESET button you will hear a click as the button engages 4 The power supply cord is now energized and supplying electricity to the air conditioner it is indicated by a light on the plug head Under no circumstances should this device be used to turn the unit on or off The RESET b...

Страница 7: ...perature of 25 C 4 TEMP Pressing this button in cooling mode adjusts the required room temperature by 1 C to a minimum temperature of 17 C Pressing this button in heating function adjusts the required room temperature by 1 C to a minimum temperature of 15 C 5 LED DISPLAY The display shows the current ambient temperature in operation By pressing the or buttons the required target temperature is dis...

Страница 8: ...xpired the delayed start up will be cancelled the unit turns on and can be operated in the required operating mode How to program a delayed shutdown This function is used to set the number of hours delay before the appliance goes off Proceed as follows Start the unit in required function cooling heating or dehumidifying Press the TIMER button during operation and enter the required number of hours...

Страница 9: ...on the appliance Reception is confirmed by a beep from the main unit The remote control will not operate if curtains door or other material block the signal from the receiver to the remote control Prevent any liquid from falling into the remote control Do not expose the remote control to direct sunlight or heat if the infrared signal receiver on the indoor unit is exposed to sunlight the air condi...

Страница 10: ...con The warm extract air must be emitted from the room via the exhaust hose Make sure that no warm outside air can enter the room For effective cooling we recommend our selection of various accessories which reduce or prevent entry of warm air into the room Set the function to COOLING Set the target temperature using the temperature control The target temperature can range between 17 C and 30 C 65...

Страница 11: ...g cooled by pushing it into the hole The sensor must face the room being cooled and be positioned above the air outlet 3 Remove the plastic cover from the remote sensor jack on the main body of the unit found near the top of the front of the unit Keep it for later use 4 Attach the end of the supplied cable to the jack on the main unit Organize the wire so it will not get damaged stepped on or pinc...

Страница 12: ...ide of the unit and attach the drainage hose Allow water to flow out continuously into a bucket or floor drain in order to achieve higher dehumidification capacity In the dehumidify mode you must not feed the room air outside with the extract air hose Note In the dehumidify mode the ventilation level is already preset to ensure efficient dehumidification of ambient air You will not be able to adju...

Страница 13: ...NDED PERIOD OF NON USE If the air conditioner will not be used for a long period of time remove the bottom rubber plug from the back hole and attach a section of the Continuous Drain Hose and completely drain the unit of water Follow cleaning instructions A D Perform reverse Installation Instructions Repack the unit in its original package and store upright in a cool dry place Important Always sto...

Страница 14: ...g the air from being discharged Position the air hose correctly keeping it as short and free of curves as possible to avoid bottlenecks Check and remove any obstacles obstructing air discharge Room is not cool enough Windows doors in room are open There are heat sources nearby Exhaust air duct is not connected or is blocked Temperature setting is too high Air filter blocked by dust Close all windo...

Страница 15: ...he unit requires qualified inspection E2 Temperature of the cooling agent lines too high or too low Temporary error on measuring output temperature Please switch the TRANSFORM unit off and start it again after approx 30 minutes If the error occurs continuously the unit requires qualified inspection E3 Incorrect signal This error message in the cooling function refers to too high ambient temperatur...

Страница 16: ...rs compressor only Implied Warranties Any implied warranties which the purchaser may have are limited in duration to 1 year for parts and 5 years for the compressor only from the date of purchase This limited warranty is in lieu of all other warranties expressed or implied including warranties of merchantability and fitness for a particular purpose and excludes all liability for incidental or cons...

Отзывы: