Kenmore 153.586420 Скачать руководство пользователя страница 21

21

material, and then chlorinating the water heater tank and all hot 
water lines. Contact the local Sears Service Center for further 
information concerning an Anode Replacement Kit #9001453 
and this Chlorination Treatment. 

Anode replacement and 

chlorination of the tank are not covered by the water heater’s 
limited warranty.

If the smelly water persists after the anode replacement and 
chlorination treatment; then you should consider chlorinating or 
aerating your water supply.

Do not remove the anode leaving the tank unprotected. By 
doing so, all warranty on the water heater tank is voided.

“AIR” IN HOT WATER FAUCETS

HYDROGEN GAS: Hydrogen gas can be produced in a hot 
water system that has not been used for a long period of time 
(generally two weeks or more). Hydrogen gas is extremely 
flammable and explosive. To prevent the possibility of injury 
under these conditions, we recommend the hot water faucet 
be opened for several minutes at the kitchen sink before any 
electrical appliances which are connected to the hot water 
system are used (such as a dishwasher or washing machine). 
If hydrogen gas is present, there will probably be an unusual 
sound similar to air escaping through the pipe as the hot water 
faucet is opened. There must be no smoking or open flame near 
the faucet at the time it is open.

RUMBLING NOISE

In some water areas, scale or mineral deposits will build up on 
your heating elements. This buildup will cause a rumbling noise. 
Follow “Element Cleaning/Replacement” instructions to clean 
and replace the elements.

HIGH TEMPERATURE SHUT OFF SYSTEM

The water heater has a high limit shut off system with a reset 
button located on the thermostat.

Follow the resetting instructions which refer to the high limit 
behind the access panel.

1.    Before beginning, turn “OFF” electrical power supply to the 

water heater.

FIGURE 30

2.   Remove the two screws securing the access panel and 

remove panel.

3.    Remove the insulation block to expose the terminal cover.

4.    Reset the high limit by pushing in the red button marked 

“RESET”.

RESET
BUTTON

FIGURE 31

5.    Replace the insulation block so that it is completely covers 

the thermostat and element.

6.    Replace the access panel.

7.    Turn “ON” electric power to the water heater.

NOT ENOUGH OR NO HOT WATER

1.    In a new installation, the water heater may not be properly 

connected. Make sure the cold water supply valve is open. 
Review and check piping installation. Make sure that the 
cold water line is connected to the cold water inlet to the 
water heater and the hot water line to the hot water outlet 
on the water heater.

2.    Make sure the electrical supply to your water heater is “ON”.

3.    Check for loose or blown fuses in your water heater circuit. 

Circuit breakers weaken with age and may not handle their 
rated load and should be replaced.

4.    Make certain the disconnect switch, if used, is in the “ON” 

position.

5.    Check to see the electric service to your house has not been 

interrupted. If this is the case, contact the electric company.

6.  Is the thermostat set to the desired temperature? See 

“Temperature Regulation” section.

7.  If you had experienced very hot water and now no hot water, 

the problem may be due to the high temperature shut off 
system. See “High Temperature Shut Off System” in the 
“Troubleshooting” section.

8.  During very cold weather, the incoming water will also be 

colder and it will require a longer time to become heated.

9.  The hot water usage may exceed the capacity of the water heater. 

If so, wait for water heater to recover after abnormal demand. Also 
examine pipes and faucets for possible water leaks.

10.  If you can not determine the problem, then call the Sears 

Service Department.

WATER IS TOO HOT

Adjust the thermostat to a lower setting See the “Temperature 
Regulation” section.

Содержание 153.586420

Страница 1: ...e reference Si no puede leer o entender el inglés y necesita el manual de instrucciones en español puede solicitarlo al 1 800 821 2017 NO TRATE DE INSTALAR U OPERAR ESTE CALENTADOR DE AGUA SI NO ENTIENDE LAS INSTRUCCIONES No hacer caso de esta advertencia podría originar lesiones graves o mortales ADVERTENCIA P N 100267599 0915 Sears Brands Management Corporation Hoffman Estates IL 60179 U S A www...

Страница 2: ... in the act This product is certified to comply with a maximum weighted average of 0 25 lead content as required in some areas IMPORTANT DEFINITIONS Sears Service Center The Sears Service Center has the ability equivalent to a licensed tradesman in the fields of plumbing and electrical work including a thorough understanding of the requirements of the National Electrical Code as it relates to the ...

Страница 3: ...3 GENERAL SAFETY ...

Страница 4: ...e the appropriate certification logo Disclaimer of implied warranties limitation of remedies Customer s sole and exclusive remedy under this limited warranty shall be product repair or replacement as provided herein Implied warranties including warranties of merchantability or fitness for a particular purpose are limited to one year on the water heater and six years on the tank and parts or the sh...

Страница 5: ...g Diagram 13 SERVICE AND ADJUSTMENT 14 Temperature Regulation 14 Thermostat 14 Temperature Settings 14 Thermostat Adjustment 14 Anode Rod Inspection 15 Temperature Pressure Relief Valve Operation 15 Draining and Flushing 16 Thermostat Removal Replacement 16 Element Cleaning Replacement 16 18 Drain Valve Washer Replacement 19 Service 19 TROUBLESHOOTING GUIDE 20 21 Start Up Conditions 20 Thermal Exp...

Страница 6: ...company or by writing Underwriters Laboratories Inc 333 Pfingsten Road Northbrook IL 60062 It can also be obtained from the National Fire Protection Association 11 Tracy Drive Avon MA 02322 9908 If after reading this manual you have any questions or do not understand any portion of the instructions call Sears Service Center Carefully plan the place where you are going to put the water heater Corre...

Страница 7: ...RMAL EXPANSION CONDITIONS AVAILABLE IN 2 GALLONS AND 5 GALLONS CAPACITY THROUGH LOCAL SEARS STORE OR SERVICE CENTER METAL DRAIN PANS AVAILABLE IN 20 DIAMETER FOR WATER HEATERS HAVINGADIAMETER 18 OR LESS AND IN 24 DIAMETER FOR WATER HEATERS HAVING A DIAMETER OF 22 OR LESS WATER HEATER INSTALLATION KIT WITH FLEXIBLE CONNECTORS FOR 3 4 THREADED OR COPPER PLUMBING SOLDER FLUX Basic Tools You may or ma...

Страница 8: ...r piping to the water heater the two copper water pipes can be cut with a hacksaw approximately four inches away from where they connect to the water heater This will avoid cutting off the pipes too short Additional cuts can be made later if necessary Disconnect the temperature pressure relief valve drain line When the water heater is drained disconnect the hose from the drain valve Close the drai...

Страница 9: ...when leakage is detected Sensors mounted in the drain pan that turn off the water supply to the entire home when water is detected in the drain pan Water supply shut off devices that activate based on the water pressure differential between the cold water and hot water pipes connected to the water heater INSTALLATION IN RESIDENTIAL GARAGES The water heater must be located and or protected so it is...

Страница 10: ...line directly to the cold water inlet It will harm the dip tube and damage the tank 1 Take off the cabinet top to make all the water and electrical connections Pull the cabinet top forward all the way until it is free When replacing the top put it on the clips almost to the back push down and then push back NOTE FIGURE 8 shows a typical installation 2 Locate the hot water outlet and put two or thr...

Страница 11: ... can cause restriction and reduce the discharge capacity of the valve No valve or other obstruction is to be placed between the relief valve and the tank Do not connect tubing directly to discharge drain unless a 6 inch air gap is provided To prevent bodily injury hazard to life or property damage the relief valve must be allowed to discharge water in quantities should circumstances demand If the ...

Страница 12: ...ing plate Failure to use the correct voltage can cause problems which can result in DEATH SERIOUS BODILY INJURY OR PROPERTY DAMAGE If you have any questions or doubts consult your electric company If wiring from your fuse box or circuit breaker box was aluminum for your old water heater replace it with copper wire If you wish to reuse the existing aluminum wire have the connection at the water hea...

Страница 13: ...tion 7 Replace the wiring junction cover using the screw provided 8 Replace the cabinet top Put it on the clips almost to the back push down and then push back GND JUNCTION BOX FRONT COVER REMOVED GROUND WIRE FRONT OF WATER HEATER FIGURE 10 Wiring Diagram FIGURE 11 ...

Страница 14: ...on unattended in a bathtub or shower Thermostat The thermostat of this water heater has been factory set at the lowest position which approximates 120 F 49 C to reduce the risk of scald injury The thermostat is adjustable if a different water temperature is desired Read all warnings in this manual and on the water heater before proceeding ADJUSTABLE THERMOSTAT BEHIND ACCESS PANEL FIGURE 12 Thermos...

Страница 15: ...to be intact Replacement of a depleted anode rod can extend the life of your water heater Inspection should be conducted by calling Sears Service Center At a minimum the anode s should be checked annually after the warranty period In replacing the anode 1 Turn off power to the water heater 2 Shut off the water supply and open a nearby hot water faucet to depressurize the water tank 3 Drain approxi...

Страница 16: ...with hose connected allowing water to terminate to an adequate drain 7 Turn ON power to the water heater Never use this water heater unless it is completely full of water To prevent damage to the tank and heating element the tank must be filled with water Water must flow from the hot water faucet before turning ON power Thermostat Removal Replacement 1 Turn OFF the electrical power to the water he...

Страница 17: ...E 19 The water passing out of the drain valve may be extremely hot To avoid being scalded make sure all connections are tight and that the water flow is directed away from any person 4 Remove the two screws at the bottom of the water heater securing the access panel and remove panel FIGURE 20 5 Remove the insulation expose the terminal cover and element FIGURE 21 6 Lift out the tab as shown to unc...

Страница 18: ...er faucet Allow water to run until a constant flow is obtained This will let air out of the water heater and the piping Never use this water heater unless it is completely full of water To prevent damage to the tank and heating element the tank must be filled with water Water must flow from the hot water faucet before turning ON power 14 Check element for water leaks If leakage occurs tighten elem...

Страница 19: ...e the washer and put the new one in place Screw the handle and cap assembly back into the drain valve and retighten using a wrench DO NOT OVER TIGHTEN Follow Filling the Water Heater instructions in the Installation Instructions section Check for leaks Turn ON electric power to the water heater FIGURE 28 Service Before calling for repair service read the Start Up Conditions and Operational Conditi...

Страница 20: ...r Length 153 331021 2 8 203 mm 12 3 4 323 mm 3 4 Male 153 331051 5 11 279 mm 14 3 4 375 mm 3 4 Male Expansion Tank Capacity Needed Inlet Water Pressure Water Heater Capacity Gallons 27 30 40 50 66 40 psi 2 2 2 2 5 50 psi 2 2 2 5 5 60 psi 2 2 2 5 5 70 psi 2 2 2 5 5 80 psi 2 2 5 5 5 Highest recorded inlet water pressure in a 24 hour period or regulated water pressure Note Expansion tanks are pre cha...

Страница 21: ... Before beginning turn OFF electrical power supply to the water heater FIGURE 30 2 Remove the two screws securing the access panel and remove panel 3 Remove the insulation block to expose the terminal cover 4 Reset the high limit by pushing in the red button marked RESET RESET BUTTON FIGURE 31 5 Replace the insulation block so that it is completely covers the thermostat and element 6 Replace the a...

Страница 22: ...od fitting may be leaking E The element may be leaking at the tank fitting Turn electrical power OFF remove access panel and insulation cap with handle If leaking around element follow proper draining instructions and remove element Reposition or replace gasket on element Place element into opening and tighten securely Then follow Filling the Water Heater instructions in the Installation Instructi...

Страница 23: ...PARTS ALWAYS GIVE THE FOLLOWING INFORMATION Model Number Part Number Serial Number Part Description THIS IS A REPAIR PARTS LIST NOT A PACKING LIST REPAIR PARTS LIST 1 2 3 4 5 6 7 7 8 9 10 11 12 13 14 15 16 17 Model No Key No Part Description 153 586420 1 Upper Terminal Cover 9002438015 2 Lower Terminal Cover 9002276015 3 Upper Thermostat 9001954015 4 Lower Thermostat 9000507015 5 Upper Element 900...

Страница 24: ...RUH FRP Q DQDGD Q DQDGD Q DQDGD Q DQDGD ZZZ VHDUV FD DOO DQ WLPH IRU WKH ORFDWLRQ RI RXU QHDUHVW 6HDUV 6HDUV 6HDUV 6HDUV 3DUWV 5HSDLU 6HUYLFH HQWHU 3DUWV 5HSDLU 6HUYLFH HQWHU 3DUWV 5HSDLU 6HUYLFH HQWHU 3DUWV 5HSDLU 6HUYLFH HQWHU 8 6 DQDGD 7R SXUFKDVH D SURWHFWLRQ DJUHHPHQW RQ D VHUYLFHDEOH SURGXFW 8 6 DQDGD 3DUD SHGLU VHUYLFLR GH UHSDUDFLÚQ D GRPLFLOLR RUGHQDU SLH DV 68 68 68 68 2 5 2 5 2 5 2 5 ZZ...

Отзывы: