Kenmore 153.586420 Скачать руководство пользователя страница 11

11

Temperature-Pressure Relief Valve

Explosion Hazard

‡ 7HPSHUDWXUHSUHVVXUHUHOLHI

YDOYHPXVWFRPSO\ZLWK$16,
=&6$DQG$60(
FRGH

‡ 3URSHUO\VL]HGWHPSHUDWXUH

SUHVVXUHUHOLHIYDOYHPXVWEH
LQVWDOOHGLQRSHQLQJSURYLGHG

‡ 'RQRWSOXJEORFNRUFDSWKH

GLVFKDUJHOLQH

‡ )DLOXUHWRIROORZWKLVZDUQLQJ

FDQUHVXOWLQH[FHVVLYHWDQN
SUHVVXUHVHULRXVLQMXU\RU
GHDWK

This heater is provided with a properly certified combination 
temperature - pressure relief valve by the manufacturer.
The valve is certified by a nationally recognized testing laboratory 

that maintains periodic inspection of production of listed 

equipment of materials as meeting the requirements for Relief 

Valves for Hot Water Supply Systems, ANSI Z21.22 • CSA 4.4, 

and the code requirements of ASME.
If replaced, the valve must meet the requirements of local codes, 

but not less than a combination temperature and pressure relief 

valve certified as indicated in the above paragraph.
The valve must be marked with a maximum set pressure not to 

exceed the marked hydrostatic working pressure of the water 

heater (150 psi = 1,035 kPa) and a discharge capacity not less 

than the water heater input rate as shown on the model rating 

plate. (For electric heaters, watts x 3.412 equals Btu/hr input 

rate). For safe operation of the water heater, the relief valve 

must not be removed from its designated opening nor plugged.
The temperature-pressure relief valve must be installed directly 

into the fitting of the water heater designed for the relief valve.  

Position the valve downward and provide tubing so that any 

discharge will exit only within 6 inches (153 mm) above, or at any 

distance below the structural floor.  Be certain that no contact is 

made with any live electrical part.  The discharge opening must 

not be blocked or reduced in size under any circumstances.  

Excessive length, over 30 feet (9.14 m), or use of more than 
four elbows can cause restriction and reduce the discharge 
capacity of the valve.

No valve or other obstruction is to be placed between the relief 
valve and the tank.  Do not connect tubing directly to discharge 
drain unless a 6 inch air gap is provided.  To prevent bodily 
injury, hazard to life, or property damage, the relief valve must 
be allowed to discharge water in quantities should circumstances 
demand.  If the discharge pipe is not connected to a drain or other 
suitable means, the water flow may cause property damage.

The Discharge Pipe:
•  Must not be smaller in size than the outlet pipe size of the 

valve, or have any reducing couplings or other restrictions.

•  Must not be plugged or blocked.
•  Must be of material listed for hot water distribution.
•  Must be installed so as to allow complete drainage of both the 

temperature-pressure relief valve, and the discharge pipe.

•  Must terminate a maximum of six inches above a floor drain 

or external to the building. In cold climates, it is recommended 

that the discharge pipe be terminated at an adequate drain 

inside the building.

•  Must not have any valve between the relief valve and tank.

The temperature-pressure relief valve must be manually operated 

at least once a year.  Caution should be taken to ensure that 

(1) no one is in front of or around the outlet of the temperature-

pressure relief valve discharge line, and (2) the water manually 

discharged will not cause any bodily injury or property damage 

because the water may be extremely hot.
If after manually operating the valve, it fails to completely reset 

and continues to release water, immediately close the cold water 

inlet to the water heater, follow the draining instructions, and 
replace the temperature-pressure relief valve with a new one.

RELIEF VALVE

DISCHARGE 

PIPE

(DO NOT

CAP OR

PLUG)

6” MAXIMUM 

AIR GAP

FLOOR DRAIN

COLD INLET

WATER LINE

SHUT-OFF VALVE

FLEXIBLE WATER CONNECTION

FLEXIBLE WATER 

CONNECTION

3/4” THREADED 

NIPPLE

3/4” THREADED NIPPLE

HOT OUTLET

WATER LINE

THREADED TO 

SWEAT COUPLING

THREADED TO 

SWEAT COUPLING

BACK OF

WATER HEATER

FRONT OF

WATER HEATER

FIGURE 9

Содержание 153.586420

Страница 1: ...e reference Si no puede leer o entender el inglés y necesita el manual de instrucciones en español puede solicitarlo al 1 800 821 2017 NO TRATE DE INSTALAR U OPERAR ESTE CALENTADOR DE AGUA SI NO ENTIENDE LAS INSTRUCCIONES No hacer caso de esta advertencia podría originar lesiones graves o mortales ADVERTENCIA P N 100267599 0915 Sears Brands Management Corporation Hoffman Estates IL 60179 U S A www...

Страница 2: ... in the act This product is certified to comply with a maximum weighted average of 0 25 lead content as required in some areas IMPORTANT DEFINITIONS Sears Service Center The Sears Service Center has the ability equivalent to a licensed tradesman in the fields of plumbing and electrical work including a thorough understanding of the requirements of the National Electrical Code as it relates to the ...

Страница 3: ...3 GENERAL SAFETY ...

Страница 4: ...e the appropriate certification logo Disclaimer of implied warranties limitation of remedies Customer s sole and exclusive remedy under this limited warranty shall be product repair or replacement as provided herein Implied warranties including warranties of merchantability or fitness for a particular purpose are limited to one year on the water heater and six years on the tank and parts or the sh...

Страница 5: ...g Diagram 13 SERVICE AND ADJUSTMENT 14 Temperature Regulation 14 Thermostat 14 Temperature Settings 14 Thermostat Adjustment 14 Anode Rod Inspection 15 Temperature Pressure Relief Valve Operation 15 Draining and Flushing 16 Thermostat Removal Replacement 16 Element Cleaning Replacement 16 18 Drain Valve Washer Replacement 19 Service 19 TROUBLESHOOTING GUIDE 20 21 Start Up Conditions 20 Thermal Exp...

Страница 6: ...company or by writing Underwriters Laboratories Inc 333 Pfingsten Road Northbrook IL 60062 It can also be obtained from the National Fire Protection Association 11 Tracy Drive Avon MA 02322 9908 If after reading this manual you have any questions or do not understand any portion of the instructions call Sears Service Center Carefully plan the place where you are going to put the water heater Corre...

Страница 7: ...RMAL EXPANSION CONDITIONS AVAILABLE IN 2 GALLONS AND 5 GALLONS CAPACITY THROUGH LOCAL SEARS STORE OR SERVICE CENTER METAL DRAIN PANS AVAILABLE IN 20 DIAMETER FOR WATER HEATERS HAVINGADIAMETER 18 OR LESS AND IN 24 DIAMETER FOR WATER HEATERS HAVING A DIAMETER OF 22 OR LESS WATER HEATER INSTALLATION KIT WITH FLEXIBLE CONNECTORS FOR 3 4 THREADED OR COPPER PLUMBING SOLDER FLUX Basic Tools You may or ma...

Страница 8: ...r piping to the water heater the two copper water pipes can be cut with a hacksaw approximately four inches away from where they connect to the water heater This will avoid cutting off the pipes too short Additional cuts can be made later if necessary Disconnect the temperature pressure relief valve drain line When the water heater is drained disconnect the hose from the drain valve Close the drai...

Страница 9: ...when leakage is detected Sensors mounted in the drain pan that turn off the water supply to the entire home when water is detected in the drain pan Water supply shut off devices that activate based on the water pressure differential between the cold water and hot water pipes connected to the water heater INSTALLATION IN RESIDENTIAL GARAGES The water heater must be located and or protected so it is...

Страница 10: ...line directly to the cold water inlet It will harm the dip tube and damage the tank 1 Take off the cabinet top to make all the water and electrical connections Pull the cabinet top forward all the way until it is free When replacing the top put it on the clips almost to the back push down and then push back NOTE FIGURE 8 shows a typical installation 2 Locate the hot water outlet and put two or thr...

Страница 11: ... can cause restriction and reduce the discharge capacity of the valve No valve or other obstruction is to be placed between the relief valve and the tank Do not connect tubing directly to discharge drain unless a 6 inch air gap is provided To prevent bodily injury hazard to life or property damage the relief valve must be allowed to discharge water in quantities should circumstances demand If the ...

Страница 12: ...ing plate Failure to use the correct voltage can cause problems which can result in DEATH SERIOUS BODILY INJURY OR PROPERTY DAMAGE If you have any questions or doubts consult your electric company If wiring from your fuse box or circuit breaker box was aluminum for your old water heater replace it with copper wire If you wish to reuse the existing aluminum wire have the connection at the water hea...

Страница 13: ...tion 7 Replace the wiring junction cover using the screw provided 8 Replace the cabinet top Put it on the clips almost to the back push down and then push back GND JUNCTION BOX FRONT COVER REMOVED GROUND WIRE FRONT OF WATER HEATER FIGURE 10 Wiring Diagram FIGURE 11 ...

Страница 14: ...on unattended in a bathtub or shower Thermostat The thermostat of this water heater has been factory set at the lowest position which approximates 120 F 49 C to reduce the risk of scald injury The thermostat is adjustable if a different water temperature is desired Read all warnings in this manual and on the water heater before proceeding ADJUSTABLE THERMOSTAT BEHIND ACCESS PANEL FIGURE 12 Thermos...

Страница 15: ...to be intact Replacement of a depleted anode rod can extend the life of your water heater Inspection should be conducted by calling Sears Service Center At a minimum the anode s should be checked annually after the warranty period In replacing the anode 1 Turn off power to the water heater 2 Shut off the water supply and open a nearby hot water faucet to depressurize the water tank 3 Drain approxi...

Страница 16: ...with hose connected allowing water to terminate to an adequate drain 7 Turn ON power to the water heater Never use this water heater unless it is completely full of water To prevent damage to the tank and heating element the tank must be filled with water Water must flow from the hot water faucet before turning ON power Thermostat Removal Replacement 1 Turn OFF the electrical power to the water he...

Страница 17: ...E 19 The water passing out of the drain valve may be extremely hot To avoid being scalded make sure all connections are tight and that the water flow is directed away from any person 4 Remove the two screws at the bottom of the water heater securing the access panel and remove panel FIGURE 20 5 Remove the insulation expose the terminal cover and element FIGURE 21 6 Lift out the tab as shown to unc...

Страница 18: ...er faucet Allow water to run until a constant flow is obtained This will let air out of the water heater and the piping Never use this water heater unless it is completely full of water To prevent damage to the tank and heating element the tank must be filled with water Water must flow from the hot water faucet before turning ON power 14 Check element for water leaks If leakage occurs tighten elem...

Страница 19: ...e the washer and put the new one in place Screw the handle and cap assembly back into the drain valve and retighten using a wrench DO NOT OVER TIGHTEN Follow Filling the Water Heater instructions in the Installation Instructions section Check for leaks Turn ON electric power to the water heater FIGURE 28 Service Before calling for repair service read the Start Up Conditions and Operational Conditi...

Страница 20: ...r Length 153 331021 2 8 203 mm 12 3 4 323 mm 3 4 Male 153 331051 5 11 279 mm 14 3 4 375 mm 3 4 Male Expansion Tank Capacity Needed Inlet Water Pressure Water Heater Capacity Gallons 27 30 40 50 66 40 psi 2 2 2 2 5 50 psi 2 2 2 5 5 60 psi 2 2 2 5 5 70 psi 2 2 2 5 5 80 psi 2 2 5 5 5 Highest recorded inlet water pressure in a 24 hour period or regulated water pressure Note Expansion tanks are pre cha...

Страница 21: ... Before beginning turn OFF electrical power supply to the water heater FIGURE 30 2 Remove the two screws securing the access panel and remove panel 3 Remove the insulation block to expose the terminal cover 4 Reset the high limit by pushing in the red button marked RESET RESET BUTTON FIGURE 31 5 Replace the insulation block so that it is completely covers the thermostat and element 6 Replace the a...

Страница 22: ...od fitting may be leaking E The element may be leaking at the tank fitting Turn electrical power OFF remove access panel and insulation cap with handle If leaking around element follow proper draining instructions and remove element Reposition or replace gasket on element Place element into opening and tighten securely Then follow Filling the Water Heater instructions in the Installation Instructi...

Страница 23: ...PARTS ALWAYS GIVE THE FOLLOWING INFORMATION Model Number Part Number Serial Number Part Description THIS IS A REPAIR PARTS LIST NOT A PACKING LIST REPAIR PARTS LIST 1 2 3 4 5 6 7 7 8 9 10 11 12 13 14 15 16 17 Model No Key No Part Description 153 586420 1 Upper Terminal Cover 9002438015 2 Lower Terminal Cover 9002276015 3 Upper Thermostat 9001954015 4 Lower Thermostat 9000507015 5 Upper Element 900...

Страница 24: ...RUH FRP Q DQDGD Q DQDGD Q DQDGD Q DQDGD ZZZ VHDUV FD DOO DQ WLPH IRU WKH ORFDWLRQ RI RXU QHDUHVW 6HDUV 6HDUV 6HDUV 6HDUV 3DUWV 5HSDLU 6HUYLFH HQWHU 3DUWV 5HSDLU 6HUYLFH HQWHU 3DUWV 5HSDLU 6HUYLFH HQWHU 3DUWV 5HSDLU 6HUYLFH HQWHU 8 6 DQDGD 7R SXUFKDVH D SURWHFWLRQ DJUHHPHQW RQ D VHUYLFHDEOH SURGXFW 8 6 DQDGD 3DUD SHGLU VHUYLFLR GH UHSDUDFLÚQ D GRPLFLOLR RUGHQDU SLH DV 68 68 68 68 2 5 2 5 2 5 2 5 ZZ...

Отзывы: