Содержание 153.330401

Страница 1: ...rs and liq uids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building i Immediately call your gas suppher from a netghbor s phone Follow the gas supplier s nstructions If you can not reach your gas supplier call the fire department Installation and service must be perform...

Страница 2: ...ting the requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems and the latest edition of ANSI Z21 22 and the code requirements of ASME If replaced the valve must meet the requirements of local codes but not less than a combination temperature and pressure relief valve certified as meeting the requirements for Relief Valves and Automatic Gas Shutoff Devices f...

Страница 3: ...ARNING VENT DAMPERS Any vent damper whether it Is operat ed thermally or otherwise must be removed if its use inhibits proper drafting of the water heater Thermally Operated Vent Dampers Gas fired water heaters having thermal efficiency in excess of 80 may reduce a relatively low flue gas temperature Such tem peratures may not be high enough to properly open ther mally operated vent dampers This w...

Страница 4: ... AWARNING Do not use this appliance if any part of it has been under J water Immediately call a Sears Service Technician to I inspect the appliance and to replace the gas control or any part of the burner system which has been under water _ WARNING HYDROGEN GAS Hydrogen gas can be produced in a hot water system that has not been used for a long period of time generally two weeks or more Hydrogen g...

Страница 5: ...ater 13 Venting 13 14 Gas Piping 14 15 Installation Checklist 16 Operating Instructions 17 19 Eighting 17 18 Temperature Regulation 19 Service and Adjustment 20 22 Tank Sediman0 Cleaning 20 Vendng System Impe_ion 20 Burner Inslx edon 20 Burner Clewing 20 Draining 21 Temperatu_Pr_ _e ll_ief Val_ Operation 21 Drain Valve Washer Reph_etu 21 Housekeeping 21 Service 21 Troubleshooting Guide 22 25 Start...

Страница 6: ...nd your safety Sincewe cannot put everything on the first few pages READ THE ENTIRE MANUAL BEFORE ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER The installationmust conform with the instructions in this manual _as company rules and Local Codes or in the absenceorLocalCodes with the latestedition of the National Fuel Gas code ANSI Z223 1 also referredto as NFPA 54 This publication is available ...

Страница 7: ...ETER FOR WATER HEATERS HAVING A DIAME WATER HEATER HEAT TER 18 OR LESS AND AVAILABLE IN TRAPS HELP REDUCE HEAT 28 DIAMETER FOR WATER HEATERS LOSS DUE TO THERMAL HAVING A DIAMETER 26 OR LESS SYPHONING Basic Tools You may or may not need all of these tools depending on your type of installation These tools can be purchased at your local Sears store Pipe Wrenches 2 14 Screwdriver Tin Snips 6 Foot Tap...

Страница 8: ...heater the two copper water pipes can be cut with a hacksaw approximately 4 away from where they connect to the water heater This will avoid cutting off the pipes too short Additional cuts can he made later if necessary Disconnect the temperature pressure relief valve drain line When the water heater is drained disconnect the hose from the drainvalve Close the drainvalve The water heater is now co...

Страница 9: ...being ignited gasoline andother flammablesubstances shouldneverbe storedor used in the same room or area con taininga gaswater heater or other opengame or sparkproduc ingappliance NOTE Flammable vaporsmay be drawn by air currentsfrom otherareasof the structureto the appliance _ WARNING Propellants of aerosol spraysand volatile compounds dean ers chlorine basedchemicals refrigerants etc in addition...

Страница 10: ...freeareaof 1 square inch per 4 000 BTU per hour of total input rating of all equipment in the enclosure SeeFigure 3 2 When communicating with the outdoors through vertical ducts each opening shall have a minimum free area of 1 square inch per 4 000 BTU per hour of total input rating of allequipment in the enclosure SeeFigure4 OHI_E _ Ot_ VENT VE_T_ LC _ 3 When communicating with the outdoors throu...

Страница 11: ...he top cover of the water heater The cold water inlet is markedcold Put two or three turns of teflon tape around the threaded end of the threaded to sweat coupling and around both ends of the threaded nipple Usingflexi ble connectors connect the cold water pipe to the coldwater inlet of the waterheater NOTE This water heater is super insulated to minimize heat loss from the tank Further reduction ...

Страница 12: ...scharge capacityofthe valve No vuiveer other obsttuctlneis tu be pincodbetweenthe rafief valveandthe tank Do not connecttubing directlyto discharge drain unless a 6 air gapisprovided Topreventbodilyinjury haz ard to life or propertydamage the relief valvemustbe allowed to dischargewater in quantities should drcumstances demand if the discharge pipeis not connectedto a drain or other suitable means...

Страница 13: ...erly open thermally operated vent dampers Thiswould cause spillage of Iluegases andmaycause carbon monoclepoisoning Ventdampers mustbearevidence of certification ascompiying withthe latesteditionof AmericanNationalStandardANSI Z21 68 ANSI 7 21 66 67 mspec6vely coverelectrically mechanically actuated ventdampers Before imtall_on of am ventdamper comuityourlocalSears Service Centerortbeges utility f...

Страница 14: ...will result in a fire hazard Aw m NG I Be sure vent pipe is properly connectedto prevent escapeof I uepses Id deed AWARNING Chemical vapor corrosion of the flue and vent system may occur if air for combustion containscertain chemicalvapors Spray can propellants deaning solvents refrigerator and air conditionor refrigerants _ wimming pool chemicals calcium and sodium chloride waxes bleach taxi proc...

Страница 15: ...ediment trap shall be either a tee fitting with a capped nip ple in the bottom oudet or other device recognized as an effec tive sediment trap Ifa tee fitting is used it shall be installed in conformance with one of the methods of installation shown below Connecting the gas piping to the gas control valve of the water heater can be accomplished by either of the two methods shown AWARNING Contamina...

Страница 16: ...ation so that the water heater wilt o_rate properly See Combustion Air and Ventilation inthe Factsto Consider About the Location section Is the draft hood vent piping properly secured See Venting instructions in the Installation Instructions section Is there proper deavance between the vent pipe and anything that might catch on fire See Venting_ instructions in the I nstallatzonInstructzons secuon...

Страница 17: ...lthenieavethe premise_ Lighting and operating instructions are located on front of the water heater above or to one side of the gas control valve AWARNING AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER FOR YOUR SAFETY IFYOU SMELL GAS Do not try to lightany appliance Do ont touch any eiect_cal switch do not use any phonein your building Immediately callyour gassupplierfrom a neighbor spho...

Страница 18: ...in thesafelyinformation above on thislabel If youdon tsmellgas goto the nextstep 6 Remove or open innerdoorlocatedbelowthe gas controlunit 7 Findpilot followmetaltubefromgascontrol The pilot Is located ontherighthandsideoftheburner PILOT BURNER _ THERMOCOUPLE 8 if youdon tsmellgas turnknobongascontrol counter clockwise _ _ to PILOT position Figure 7 page17 9 Pushin control knoball the wayand holdd...

Страница 19: ...settingthat satisfies your hot water needs Lmeanssuchasa mbcingvalve shouldbe usedat the hot water taps usedby thesepeople or at the water heater Mixingvalves areavailable at plumbingsupply or hardwarestore_Followman ufacturers instructions for installation of the valves Before changing the factory setting on the thermostat read the Temperature Regulation sectioninthis manual _ WARNING Nevor allow...

Страница 20: ...propellants danning solvents refrigerator and air conditioner refrigerants swimming pool chemicals calcium and sodiumchloride waxes bk_ch and processchemicalsare typicalcompoundswhich are potentiallycorrosive _ WARNING I Obstructedor deterioratodvent systemsmaypresonta seriousI heaith risk or asphyxiation I AWARNING I Be sure the vent piping is properly connected to prevent I ae_Oex _n d angerousf...

Страница 21: ...e temperature pressure relief valve must be manually operated at least once a year TEMPERATURE PRESSURE RELI VALVE Turn _OFF gas supply to water heater Follow Draining instructions Turning counter clockwise remove the hex cap below the screw handle Remove the washer and put the new one in place Screw the handle and cap assembly back into the drain valve and retighten using awrench DO NOT OVER TIGH...

Страница 22: ...stems do not allow for the expansion of heat ed water The water within the water heater tank expands as it is heated and increases the pressure of the water system If the relieving point of the water heater s temperature pressure relief valve is reached the valve will relieve the excess pressure The tempera taM pressure relief valve is not intended for the constant relief of thermal expansion This...

Страница 23: ... Contact Sears Service for further information concerning an Anode Replacement Kit 9001453 and this Chlorination Treatment If the smelly water persists after the anode replacement and chlo rination treatment we can only suggest that continuous chlori nation and filtering conditioning equipment be considered to eliminate the water problem Do not remove the anode leaving the tank unprotected By doin...

Страница 24: ... must be replaced Contact the Sears Service Center The gas control knob must be turned to the ON position TEe temperature adjustment dial may he set too low See the Temperature Regulation section The gas company cart check tke gas input to see if it is correct An underfired water heater will not heat water as quickly Look for leaking or open hot water f_ucets Make sure all are dosed The cold water...

Страница 25: ... Small amounts of water from the temperature pressure relief valve may be due to thermal expansion or high water pressure in your area Q The temperature pressure relief valve may be leaking at the tank fitting Q Water from a drain valve may be due to the valve opened slightly O The drain valve may be leaking at the tank fitting Combustion products contain water vapor which can condense on the cool...

Страница 26: ... MISER TM 12 GAS WATER HEATERS MODEL NUMBERS 153 330401 40 Gal High Altitude 153 330451 40 Gal 153 330501 50 Gal High Altitude 153 330551 50 GaL 153 330701 75 GaL High Altitude 153 330751 75 Gal 2O I 1 3 I i I 2 u o 19 18 26 ...

Страница 27: ...0230141 0230120 36 HA 33 9002617 9002617 9002411 9002411 9002494 9002494 9000281 9000281 F145 1277 F145 1277 F145 1280 F145 1280 9001208 9001208 9002443 9002443 9000945 9000945 9000273 9000273 9001792 9001792 0002915250 23600 9000071 9000071 9000734 9000734 9000948 9000948 9000254 9000254 9001584 9001584 0270118 0270118 9000284 9000284 4233900 4233900 9000278 9000278 0230160 0230144 31 HA 29 90026...

Страница 28: ...materials or workmanship Sears will furnish a replacementfree of charge You will be charged for labor If the water heater is subjected to commerdal institutional industrial or use in residencesof two families or more the above warranty coveragefor tanks that leakis effectivefor 2 yearsfromthe date of purchase and the above parts warranty is effectivefor I year fromthe date of purchase Toobtainwarr...