32
Problem Possible Cause Corrective Action
Low heat,
LP gas
The propane regulator assembly
incorporates an excess flow device
designed to supply the grill with
sufficient gas flow. Rapid changes in
pressure can trigger the excess flow
device, providing a low flame and low
temperature.
Please follow these instructions:
1. Make sure all burners are “OFF”.
2. Open the tank valve and wait 5 minutes.
3. Light the burner one at a time following the
lighting instructions listed on the door liner.
Sudden drop in gas
flow or low flame
1.
Out of gas.
2.
Excess flow valve tripped.
3.
Vapor lock at coupling nut/LP
cylinder connection.
1.
Check for gas in LP cylinder.
2.
Turn off knobs, wait 30 seconds and light
grill. If flames are still low, turn off knobs
and LP cylinder valve. Disconnect
regulator. Reconnect regulator and leak
test. Turn on LP cylinder valve, wait 30
seconds and then light grill.
3.
Turn off knobs and LP cylinder valve.
Disconnect coupling nut from cylinder.
Reconnect and retry.