background image

unlocked. It will try to unlock the door 6 times before 
displaying the error. 
 

Potential Causes

 

 
• Door Lock Mechanism broken. 
• Check Door Lock/Switch Assembly for foreign objects 
• Check Wire Harness connections to the Door 
Lock/Switch Assembly and Central Control Unit (CCU) 
• Door Lock/Switch Assembly Failure 
 
Replace failed component. 
 

Note

: The door lock/switch assembly can be manually 

unlocked. 
 
To Manually unlock the door lock system: 
 
1. Unplug the power cord from the outlet. 
2. Remove the lower toe panel. 
3. Reach up along the inside of the front panel and locate 
the bottom of the door latch assembly. 
4. Located on the bottom of the door latch assembly is a 
tear-drop shaped tab. 
5. Gently pull the tab down about 1/4 inch or until a click 
is heard. 
6. The door may now be opened. 

 

Содержание 110.44832 200

Страница 1: ...code will flash Press PAUSE CANCEL twice to clear the display Potential Causes If there is no water in the unit Make sure that both valves at the water source s are turned on all the way Check for plugged or kinked inlet hoses or plugged screens in the inlet valves Verify inlet valve operation If there is water in the unit Verify Drain pump operation Pressure Switch Hose is in good condition and p...

Страница 2: ...g high speed spin the door will be unlocked after 3 minutes Potential Causes Check wire harness connections between the Drive Motor Tachometer and the Motor ControlUnit MCU and between the MCU and the Central Control Unit CCU Check the Drive Motor Check the MCU Check the Wire Harness Replace failed component F07 Motor control unit error The Central Control Unit has detected a short in the motor co...

Страница 3: ...ess connections to the MCU the motor and Central Control Unit CCU Check the Drive system for any worn or failed components Check MCU Check Motor Replace failed component F11 Serial communication error Communication between the Central Control Unit CCU and the Motor Control Unit MCU cannot be sent correctly Potential Causes Check Wire Harness connections to the MCU the motor and Central Control Uni...

Страница 4: ...bad pump an extra heavy load excessive detergent or excessive suds Potential Causes If too much detergent was used run the unit through a Rinse Spin cycle then a Normal cycle without adding any detergent This should clear the unit of the excess detergent Check the drain hose and make sure it is not plugged or kinked Check Wire Harness connections to the Drain Pump Pressure Switch and Central Contr...

Страница 5: ...h Assembly Failure Replace failed component Note The door lock switch assembly can be manually unlocked To Manually unlock the door lock system 1 Unplug the power cord from the outlet 2 Remove the lower toe panel 3 Reach up along the inside of the front panel and locate the bottom of the door latch assembly 4 Located on the bottom of the door latch assembly is a tear drop shaped tab 5 Gently pull ...