KENCO Kenlift
®
Operation Manual
Section V.
Operation
A.
Automatic operation
1.
Ensure that the Kenlift
®
’s capacity and range are appropriate to the median barrier wall to be
handled.
2.
Position Kenlift
®
at or near center of object to be lifted.
3.
Lower Kenlift
®
onto object, taking care to minimize impact.
4.
Ensure that all persons are clear of Kenlift
®
and wall.
5.
Release tension on lift cable.
6.
Raise Kenlift
®
and load in a smooth motion, do not “jerk”.
7.
Deposit at desired location.
8.
Release tension on lift cable. (Note: avoid undue slamming of the Kenlift
®
into open position
to prolong actuator life.)
9.
Remove Kenlift
®
(Kenlift
®
is latched in open position automatically)
Manipulation of the Kenlift
®
by ground personnel for the
purpose of alignment with load shall only be done with
Kenlift suspended above the wall.
KEEP ALL HANDS
AWAY FROM Kenlift DURING OPERATION.
DANGER
!!!!
Surfaces of the load that come into contact with the pad
surfaces
MUST BE CLEAN
and free of any foreign material
or coating that could compromise the grip.
DANGER
!!!!
Before attempting to use the Kenlift
®
device
ALWAYS
perform a test lift on the intended object(s) to confirm proper
operation.
DO NOT
use a Kenlift
®
to handle objects beyond
the rated capacity or range.
DANGER
!!!!