X5 FastMig
Operating manual - EN
2.12 Installing gas bottle and testing gas flow
Handle gas bottles with care. There is a risk of injury if the gas bottle or the bottle valve is damaged!
Always secure the gas bottle properly in an upright position to a special holder on the wall or on the welding equip-
ment cart. Always keep the gas bottle valve closed when not welding.
- If a transport unit with a gas bottle rack is used, install the gas bottle on the transport unit first, then make the con-
nections.
- Install the welding gun to the wire feeder before installing and testing the gas bottle.
- Do not use the whole contents of the bottle.
- Always use an approved and tested regulator and flow meter.
Contact your local Kemppi dealer for choosing the gas and the equipment.
1.
Without gas bottle cart: Place the gas bottle in a suitable, secure location.
2.
With gas bottle cart: Move the gas bottle on the transport unit's gas bottle rack and secure it in place with the
straps and fixing points provided.
3.
If not already, connect the welding gun to the wire feeder.
4.
Connect the gas hose to the wire feeder.
In a standard setup, the gas hose is included in the interconnection cable bundle (for more information, refer to
"Installing cables" on page 34).
© Kemppi
53
1920960 / 2039
Содержание X5 FastMig Manual 400
Страница 1: ...X5 FastMig Operating manual EN X5 FastMig Kemppi 2 1920960 2039...
Страница 29: ...X5 FastMig Operating manual EN Kemppi 30 1920960 2039...
Страница 36: ...X5 FastMig Operating manual EN 1 2 Kemppi 37 1920960 2039...
Страница 108: ...X5 FastMig K ytt ohje FI X5 FastMig Kemppi 109 1920960 2039...
Страница 136: ...X5 FastMig K ytt ohje FI Kemppi 137 1920960 2039...
Страница 143: ...X5 FastMig K ytt ohje FI 1 2 Kemppi 144 1920960 2039...