Troubleshooting
PROBLEM
POSSIBLE CAUSE
REMEDY
The wire feeding motor
M001 does not start,
when MIG gun switch is
pressed.
Start line wires are cross
connected.
Locate the cross
connection to the MIG
gun or to the Promig
Evolution and correct it.
Wire feeding can not be
stopped, when PMT gun
with RMT-10 remote
controller is connected to
the feeder.
Start line wires are cross
connected.
Locate the cross
connection to the MIG
gun or to the Promig
Evolution and correct it.
Defective remote
controller or short circuit
in the remote controller
cable.
Change or repair the
remote controller.
Remote controller (R10,
R20) does not work.
LOCAL/GUN/REMOTE
-switch is in wrong
position or broken.
Check and correct
position of the
LOCAL/GUN/ REMOTE
–switch. Replace switch
if needed.
Solenoid valve Y001 is
not working: gas is
flowing all the time or
the gas is not flowing at
all.
Faulty solenoid valve or
malfunction in the control
card A001.
Check the control voltage
(24 VDC) of the solenoid
valve from connectors
X2/10 and X2/13. If
voltage exist, the solenoid
valve is faulty.
Содержание PROMIG EVOLUTION 501
Страница 1: ...TECHNICAL MANUAL FOR PROMIG EVOLUTION 501 501L 511 530 version 1 0...
Страница 4: ...Control card A001 Layout EPROM D4 X5 X4 X3 X2 X6 X1 H3 H1 H2 1 10 X11 X12...
Страница 16: ...Prosync 50 6263121...
Страница 23: ...Measurements Solenoid valve Y001 control 2...
Страница 24: ...Measurements Remote controller connector 3 No remote controller Remote controller max Remote controller min...
Страница 26: ...Measurements MIG gun connection 4 PMT gun start Umax 4 9 V Umin 12 8 V MT gun start...
Страница 30: ...2 1 4 3...
Страница 31: ...2 1 4 3...
Страница 32: ...Notes...