Troubleshooting
PROBLEM
POSSIBLE CAUSE
REMEDY
Fuse F2 6,3A in the
power source is blown.
Change the fuse and
check that there are not
any short circuits in
control cable.
The control cable is not
properly connected or
connector X1 in the
control card A001 is
loose or broken.
Check Promig operation
v50 VDC from
the connector X1/1 and
X1/3. Check that all LED
indicators are
illuminating.
The Promig Evolution
doesn't work at all. Wire
feeding motor or
solenoid valve is not
operating. Panel displays
are not working.
Control card A001 is
faulty
Replace the control card
A001, if needed.
Connection cables
between panel and
control card A001 are
loose or they are cross
connected.
Check that the connection
cables are connected
according to main circuit
diagram.
Faulty EPROM D4
(M27C4001)
.
Replace the faulty
EPROM.
The panel P001 (MC,
ML, MXE) in Promig
Evolution is not
operating properly or
control of the Promig
Evolution is not working.
Faulty panel P001.
Replace the faulty panel.
The wire feeding motor
M001 does not start,
when torch switch is
closed.
Faulty switch, poor
connection in start lines
or problem with start line
wire insulators.
Check the switch and
start line wires of the
MIG gun. Replace if
needed.
Содержание PROMIG EVOLUTION 501
Страница 1: ...TECHNICAL MANUAL FOR PROMIG EVOLUTION 501 501L 511 530 version 1 0...
Страница 4: ...Control card A001 Layout EPROM D4 X5 X4 X3 X2 X6 X1 H3 H1 H2 1 10 X11 X12...
Страница 16: ...Prosync 50 6263121...
Страница 23: ...Measurements Solenoid valve Y001 control 2...
Страница 24: ...Measurements Remote controller connector 3 No remote controller Remote controller max Remote controller min...
Страница 26: ...Measurements MIG gun connection 4 PMT gun start Umax 4 9 V Umin 12 8 V MT gun start...
Страница 30: ...2 1 4 3...
Страница 31: ...2 1 4 3...
Страница 32: ...Notes...