Kemppi KEMPOWELD WIRE 400 Скачать руководство пользователя страница 11

KEMPOWELD WIRE 400, 550 / 0530 – 11

© COPYRIGHT KEMPPI OY

 The welding with the 2-sequence  procedure. 

1. 

Switch pressed:  welding starts

2. 

Switch open: 

welding stops

 The welding with the 4-sequence procedure.

1. 

Switch pressed:  shielding gas is flowing

2. 

Switch open: 

welding starts

3. 

Switch pressed:  welding stops

4. 

Switch open: 

gas flow stops after the burn 

 

 

back time

Spot,  cycle  arc  and  continuous  welding  (is  operating  only  in  the  2-sequence  procedure 

position)
Spot welding   

1. Set the spot time with the potentiometer R2.

2. The gun switch pressed: welding starts

3. Welding ends automatically after the set time

Cycle arc welding   

1. Set the welding cycle time with the potentiometer R2. The pause time is adjusted automatically.

2. The gun switch: cycle welding is continued for so long as the switch is pressed.

6.4. KMW SYNC

The push-pull gun is most often used for feed of thin aluminium wires, when over 5 m reach is required. You can 

connect the gun equipped with the EURO adaptor to the KMW sync unit. The push-pull gun´s potentiometer is 

connected to amphenol connector, mounted onto front wall of the wire feeder. You can connect to this connector 

also some other potentiometer, which has suitable values for it. With the unit´s switch you can select the normal 

operation or the push-pull gun operation. For right connections in the gun, contact your KEMPPI dealer.

Installation and mounting

In the KMW sync accessories are included the electronics 

card, switch, protective cap of switch, insulation bushings, 

fastening screws and cable set.

1. Remove the side plate.

2. Fasten the electronics card with screws and insulation 

bushings to fastening holes of the wire feeder unit´s 

intermediate wall.

3. Remove protection knob from cover plate by side of gun 

adapter on front wall of feeder and its underside cover 

plate totally.

4. Mount the amphenol connector to lower fastening place 

and the switch to hole, which has left on the upper cover 

plate.

5. Connect the connector for wiring from the card to the 

control card A001 to connector KMW sync, from which 

you have first removed the jumper piece.

6. Mount the push-pull gun to the feeder adaptor. In order to verify the operation, you can use even an ordinary 

welding gun.

7. Connect the push-pull gun´s connector or a potentiometer, which has been connected on a corresponding 

way, to the amphenol mounted to the feeder.

8. Test with the switch that the enclosed control is changed according to the enclosed operation description.

9. Fasten the side plate back at its place.

Hanging onto the boom

The lift hook is fastened to the handle on the cover of the feeder. The wire feeder unit´s position depends on the 

hole position.

6.3. KMW TIMER FUNCTIONS

2 / 4-sequence procedure

Содержание KEMPOWELD WIRE 400

Страница 1: ...KEMPOWELD WIRE 400 WIRE 550 Operation instructions english Gebrauchsanweisung deutsch Gebruiksaanwijzing nederlands Manuel d utilisation fran ais 1922040E 0530...

Страница 2: ...NG TO WIRE DIAMETER 8 5 2 MOUNTING OF MIG WELDING GUN 8 5 3 MOUNTING AND LOCKING OF WIRE REEL 8 5 4 ACCESSORY DRAWER 8 5 5 AUTOMATIC WIRE FEED TO GUN 8 5 6 ADJUSTMENT OF PRESSURE 9 5 7 ADJUSTMENT OF T...

Страница 3: ...ions and respect them when installing operating and servicing the machine Welding arc and spatters Welding arc hurts unprotected eyes Be careful also with re ecting arc ash Welding arc and spatter bur...

Страница 4: ...4 KEMPOWELD WIRE 400 550 0530 COPYRIGHT KEMPPI OY 2 PARTS OF WIRE FEED MECHANISM WIRE WIRE 400 ja WIRE 550...

Страница 5: ...200 and 4200W MSD 1 V A metering unit included in delivery of 5500W 3 2 PARTS OF COOLING UNIT KEMPOWELD 4200W AND 5500W S4 Main switch of cooling unit Sw1 Selecting switch for gun s cooling mode Sw2 W...

Страница 6: ...ync Accessory K3 Wire feed adjustment selection panel or push pull gun X1 Control connector for push pull gun Binzel Hulftegger Cooling unit connections 01 Return water connector for gun 02 Feed water...

Страница 7: ...will cause disturbances and excessive wear for accessories When necessary speed is changed according to following Open tightening lever 20 Remove lower feed rolls 21 Release screw 23 and its washer R...

Страница 8: ...estion Too tight a wire guide tube might cause for wire feeder unit a bigger stress than normally as well as disturbances in wire feed Screw snap connector of gun tight that there won t come any volta...

Страница 9: ...ed through hole in locking device of reel hub by screwing the control screw 41 with screwdriver Adjust brake force as so big that the wire is not allowed to become too loose on the reel so that it wou...

Страница 10: ...NTROL PANELS AND ADJUSTMENTS 6 1 WIRE FEED SPEED POTENTIOMETER R1 The wire feed speed is adjusted steplessly with the potentiometer on the front panel see the paragraph PANELS The potentiometer has th...

Страница 11: ...operation or the push pull gun operation For right connections in the gun contact your KEMPPI dealer Installation and mounting In the KMW sync accessories are included the electronics card switch pro...

Страница 12: ...ect your eyes with proper eye protection 7 1 REGULAR MAINTENANCE OF EQUIPMENT Kemppi service repair shops make regular maintenance according to agreement The major points in the maintenance procedure...

Страница 13: ...Wire feed speed I 0 18 m min 0 18 m min II 0 25 m min 0 25 m min Filler wires Fe Ss 0 6 1 2 mm 0 6 2 4 mm Filler wire 0 8 1 6 mm 1 0 1 6 mm Al 1 0 1 6 mm 1 0 1 6 mm Wire reel max weight 20 kg 20 kg ma...

Страница 14: ...T 52W 4 5 m 6255204MMT MT 51W 3 m 6255046 MT 51W 4 5 m 6255047 KMP 400W 6 m 6257406 KMP 400W 10 m 6257410 WS 30W Al 1 2 1 6 6 m 6253046A12 WS 30W SS 1 0 6 m 6253046S10 WS 30W SS 1 2 6 m 6253046S12 WS...

Страница 15: ...rantee does not cover direct or indirect travelling costs daily allowances or accommodation Note Under the terms of guarantee welding torches and their consumables feeder drive rolls and feeder guide...

Страница 16: ...076 5717 750 Telefax 076 5716 345 e mail sales nl kemppi com KEMPPI UK Ltd Martti Kemppi Building Fraser Road Priory Business Park BEDFORD MK443WH ENGLAND Tel 0845 6444201 Fax 0845 6444202 e mail sale...