FastMig MS 200, MS 300

8

EN

Setup (5)

When the adjustment of SETUP parameters has been confirmed with a long press of the 

SETUP button (10), the adjustable parameter is selected via left potentiometer (control knob) 

and the name of the parameter is shown on the left display. The parameter’s value is set via 

right potentiometer (control knob) and the value is shown on the display on the right (see 

’SETUP functions’).

Synergic 1-MIG or Wise welding (6, 10)

In Synergic 1-MIG welding, the optimal welding parameters for the welding wires and gas 

used are recorded in the unit. The welding is controlled by adjusting the welding power and 

arc length.
Wise processes are additional functions, which can be purchased separately.

Welding program selection:

Before starting to weld, a welding program suitable for the welding wire and gas used must 

be chosen based on this Operating Manual.
Welding program selection is activated by pressing Set Prog button longer than one second. 

In this case both displays begin to flash and the material group is selected with the control 

knob on the left and the welding program for the material group in question with the control 

knob on the right.
First five material groups are for Synergic 1-MIG welding and last five are for Wise processes.
Refer to the selection LED indicators on the panel for synergic welding program – indicators 

show the material, the wire thickness and the gas type in question.
The selected programme is immediately recorded in the memory. To get back to normal status 

press ON/OFF (1) key, or Set Prog button (6).

Use of a selected welding program:

The selected welding program is immediately ready for welding. Check that the welding 

program corresponds to the welding wire and shield gas in use. The selection LED indicators 

on the panel show the material, the wire thickness and the gas type in use. The welding 

program number can be checked by briefly pressing the Set Prog button (6), after which the 

displays show the welding program number.

TIP!  

The selected welding program can be saved for later use using one of the memory channels. 

Refer to 'Memory functions'.

Set the desired welding power via the left-hand potentiometer (control knob) and the arc 

length via the potentiometer (control knob) on the right.

Memory functions (2)

Storage of settings

The memory functions can be used to record useful welding values in the memory. There are 

five different memory channels under five separate memory buttons: 1 … 5.
In addition to welding values (wire feed speed, welding voltage), function options such as 

2T/4T, Creep Start, and Crater Level are recorded in the memory as well as the used welding 

program.
Short press selects the memory locations.
Long press saves the current settings to the selected memory location.

Содержание 6136300

Страница 1: ...FastMig MS 200 MS 300 1903500 1515...

Страница 2: ......

Страница 3: ...OPERATING MANUAL English...

Страница 4: ...g and mounting the panels 4 2 2 Functions of MS 200 and MS 300 panels 5 2 3 MS 200 and MS 300 operations 6 2 4 Additional welding functions 9 2 5 FastMig welding programs 11 2 6 Panel MS 200 and MS 30...

Страница 5: ...ation on Kemppi products contact Kemppi Oy consult an authorised Kemppi dealer or visit the Kemppi web site at www kemppi com The specifications presented in this manual are subject to change without...

Страница 6: ...anel MXF 65 1 2 1 Place the bottom edge of the panel behind the securing clips on the machine Remove the fixing pin from the top edge with for example a screwdriver Then gently push the upper part of...

Страница 7: ...ustment of length of welding arc 1 MIG c Adjustment of MIG dynamics d Adjustment of SETUP parameter e Selection of 1 MIG WiseRoot WiseThin welding program program number f WiseRoot and WiseThin base c...

Страница 8: ...ed with Arc Force Dynamics button the value is adjusted via right potentiometer control knob see the information on adjustment of MIG dynamics arc force With Synergic 1 MIG welding the power value is...

Страница 9: ...IG 1 MIG selected 1 MIG WISE 1 MIG and either WiseFusion or WisePenetration selected selection between the two is done through SETUP and WISE WiseRoot or WiseThin selected selection between the two is...

Страница 10: ...the selection LED indicators on the panel for synergic welding program indicators show the material the wire thickness and the gas type in question The selected programme is immediately recorded in t...

Страница 11: ...the selection button can select one or more of the above func tions Only the available additional functions for each method can be selected HotStart function is meant to reduce initial welding errors...

Страница 12: ...d The wire feed speed is kept low until the wire touches the work piece and the current begins to flow Creep Start can be selected with normal MIG welding or with Synergic 1 MIG welding WiseFusion is...

Страница 13: ...4 1 2 Fe Rutil CO 194 1 2 Fe Basic Ar 18 25 CO Ss group Wire mm Material Shielding gas 201 0 8 CrNiMo 19 12 Ar 2 CO 202 0 9 CrNiMo 19 12 Ar 2 CO 203 1 0 CrNiMo 19 12 Ar 2 CO 204 1 2 CrNiMo 19 12 Ar 2...

Страница 14: ...303 1 0 AlMg5 Ar 304 1 2 AlMg5 Ar 306 1 6 AlMg5 Ar 313 1 0 AlSi5 Ar 314 1 2 AlSi5 Ar 316 1 6 AlSi5 Ar SPE group Wire mm Material Shielding gas 401 0 8 CuSi3 Ar 402 0 9 CuSi3 Ar 403 1 0 CuSi3 Ar 404 1...

Страница 15: ...e group Wire mm Material Shielding gas Backing gas 701 0 8 Fe Ar 18 25 CO 702 0 9 Fe Ar 18 25 CO 703 1 0 Fe Ar 18 25 CO 704 1 2 Fe Ar 18 25 CO 711 0 8 Fe CO 712 0 9 Fe CO 713 1 0 Fe CO 714 1 2 Fe CO S...

Страница 16: ...ding program Syn Post Gas Time PoG 0 0 9 9 s Syn Post gas time in seconds or automatically according to synergic welding program Syn Creep Start Cr OFF on OFF Switch creep start on or off Creep Start...

Страница 17: ...h of start pulse not inWiseRoot orWiseThin Post Current Time PoC 9 9 0 Post current Synergic MIG Unit Unl m min mm A m min In 1 MIG andWiseRoot welding the parameter shown in left hand display wire fe...

Страница 18: ...have been set 6 Approve by pressing REMOTE Suc cEs PIN Code Entry PIn PIn Enters pin code for Panel Locking Panel Locking LoC OFF on OFF Enables panel locking Water Cooler Coo OFF on on Enables water...

Страница 19: ...to Ent 2 Press REMOTE 3 Set code with right potentiometer 4 Choose next with left potentiometer 5 Go back to point 3 until all codes have been set 6 Approve by pressing REMOTE Suc cEs Restore Factory...

Страница 20: ...cut off or is defective Check the extension lead and connections Err 55 Power source is busy The communication channel is busy The power source is being used by another wire feed unit or the programm...

Страница 21: ...nt addresses for the devices as follows 1 Press any button on either control panel except the ESC button Add Device Address is displayed 2 Change the device address using the right hand control knob 3...

Страница 22: ...www kemppi com...

Отзывы: