6 TECHNICAL SPECIFICATIONS
Table 2.
Feature
Description
Value
Input
AC power connection (without transformer
(multivoltage option))
3~, 380...480 V (+/-10%)
Nominal input current
262 A
524 A
786 A
Input frequency
50...60 Hz
Power factor (@ full load)
0.94
Efficiency
94 % @ nominal output
power
Output
Maximum output power
160 kW 320 kW
480 kW
Maximum output current (@ 800 V)
240 A
2x 240 A 3x 240 A
Output voltage range with 500 V module
150...500 V
Output voltage range with 800 V module
200...800 V
General
Charging cable length
5m / 7 m
Charging connection type
CCS1 , CCS2 , CHAdeMO
Protection class
IP54
Operation temperature
-40 ... +60 °C *note derating
limitation
Maximum humidity
< 95% relative humidity
Cooling
Power cabinet forced air,
satellite free air
Height ( without optional steel foundation)
Cabinet 2150 mm
Satellite 2300 mm
Dimensions (DxW), ca. (without transformer
(multivoltage option))
650 x
825 mm
1250 x
825 mm
1850 x
825 mm
Weight (CPU cabinet), approx. ( without
transformer (multivoltage option), see
datasheets)
400 kg
800 kg
1200 kg
Weight (Satellite)
60-100 kg (depending of
number of cables & options)
User interface
ON/OFF switch, two function
buttons, 7" touch screen,
RFID reader
Network connection type
Wireless 3G/4G/LTE, WiFi,
Ethernet
C- AND S-OPERATION MANUAL - EN
25
11/11/2021 1.07
Содержание C Series
Страница 1: ...C Station C Series S Series Charging System OPERATING MANUAL ...
Страница 14: ...3 6 Connector types Figure 6 1 CCS Type 2 2 CHAdeMO 3 Type 2 C AND S OPERATION MANUAL EN 12 11 11 2021 1 07 ...
Страница 23: ...5 2 CPU C501 C801 Figure 14 CPU C501 C801 C AND S OPERATION MANUAL EN 21 11 11 2021 1 07 ...
Страница 24: ...5 3 CPU C502 C802 Figure 15 CPU C502 C802 C AND S OPERATION MANUAL EN 22 11 11 2021 1 07 ...
Страница 25: ...5 4 CPU C503 C803 Figure 16 CPU C503 C803 C AND S OPERATION MANUAL EN 23 11 11 2021 1 07 ...
Страница 26: ...5 5 C Station Figure 17 Dimensions C AND S OPERATION MANUAL EN 24 11 11 2021 1 07 ...