10. TECHNICAL DATA
FreshAir Flow Control
Airflow
140 – 210 l/min
at 8 adjustable flow rates
Weight of the blower unit incl. the filter and battery
900 g
Noise level
55 – 61 dB
NiMh battery lifetime
500 – 700 charging cycles
Charging time
10 – 14 hours
Belt size
80 – 100 cm
Recommended temperature range
10 – 40 °C
Recommended humidity range
20 – 80 % Rh
Certification
EN 12 941 TH2
Operation time
See the following table
Notified body for CE testing:
Výzkumný ústav bezpečnosti práce, v.v.i. – ZL
Testing Laboratory No. 1024
Jeruzalémská 9, 116 52 Praha 1
Authorized Body 235
Notified Body 1024
Expected operating time of the blower unit after being fully
charged (hours)
Airflow
Filter
min.
middle
max.
PSL R
X
10 h
X
6 – 7 h
X
4 – 5 h
NOTE!
Operating time can be decreased where filters are clogged or the
battery is undercharged.