Insert a new filter:
1.
2.
3.
1.
If you are using a prefilter or an odor filter, place and fix it around the
new filter as tightly as possible, sticking the ends together using the
sticky tape located on the ends of the prefilter or odor filter.
2.
Put the filter back into position using the same rotating motion and
gently push until it fits well onto the body of the unit.
3.
Replace the orange filter cover. Ensure you snap the cover into place
on both sides.
6.3
About the batteries
NOTE!
Batteries are delivered discharged. All batteries must be charged
before they are used for the first time. The battery can be charged
separately or on the blower unit.
The charger must not be used for any other purpose than that for which it
was manufactured. Please read the following precautions:
• Do not charge the battery where there is a risk of explosion.
• The battery charger is intended for indoor use only.
• The charger must be protected against damp.
6.4
Charging the battery
1.
Check that the voltage of the electrical power supply is correct.
2.
Plug the charger into the socket.
3.
Connect the battery to the charger. The socket of the battery is
positioned on the back. The charging regime is identified by a red LED
diode light.
4.
After charging has been completed, the trickle charging regime is
activated: red LED diode goes out, the green LED diode comes on at
the moment of trickle charging.
5.
Disconnect the charger from the power supply.
The charger controls the charging automatically. After the battery has been
charged, the charger switches to the trickle charging regime and keeps the
battery fully charged. A full charging cycle is between 10 and 14 hours.
NOTE!
Do not leave the charger in the power supply if not in use !