Maintenance Manual KHS HS2
10
Replacing the flow
restrictor
1
Remove the cover plate.
2
Remove the control unit.
3
Remove the solenoid valves.
4
Remove the filter screen and flow
limiter.
5
Replace the flow limiter
(Art.-No. 6899900100)
and install the filter screen.
6
Use a ballpoint pen to note the new
value of the flow restrictor on
the sticker on the control unit.
7
Install the solenoid valves.
8
Install the control unit and check the
solenoid valves for correct functioning.
9
Replace the cover plate.
10 l/min
blue
blau
bleu
blauw
4
l
/
min
g
r
ey
g
rau
g
ris
grijs
15
l
/
min
g
r
ee
n
g
r
ü
n
ve
rt
groen
Kemper HS2 App
10 l/min
4 l/min
15 l/min
EN
hs2app.kemper-olpe.de
The KEMPER HS2 hygiene Flushing Box is
factory-fitted with a flow limiter to restrict
the flow to 10 l/min. By replacing the flow
restrictor, the flow can be limited to 4 l/
min or 15 l/min.