EN
1502818-00
- 57 -
Item
Designation
Item
Designation
1
Filter element
3
Sealing cap
2
Gasket ring
4
Mounting frame
Tab. 16: Filter replacement – Removing the filter element
Changing the filter element:
1. Switch the product off at the device switch.
2. Prevent unintentional restarting by disconnecting the mains plug.
3. Remove the new filter element from the box and remove the sealing cap (item 3).
Ensure the sealing ring (item 2) is not damaged in the process.
4. Gently lift the saturated filter element (item 1) and carefully pull it out of the product
(arrows A + B).
5. Seal the saturated filter element with the sealing cap (item 3) of the new filter element
to make it airtight. Dispose of the saturated filter element in accordance with current
regulations.
Fig. 13: Filter replacement – Installing the filter element
Item
Designation
Item Designation
1
Filter element
4
Mounting frame
2
Gasket ring
5
Sealing surface
Tab. 17: Filter replacement – Installing the filter element