www.kemper-olpe.de
– 04.2021 / K410058500001-00 – 9 / 12
I
nstallation - Replacing the inner
top part
2
2.1
Dismantling
Remove the operating knob. After removing the
upper section (1) with an SW 17 spanner, the
inner top part can be removed through the
shaft.
2.2
Assembly
Insert the upper section (1) through the shaft
(3) into the housing (2) and position as far as
the stop. The top part is then tightened to a
torque of 20 Nm using an SW 17 spanner. Fit
the operating knob (see Accessories) over the
retaining bush..
Accessories
3
Accessorie
Figure
Insulation shell for quarter turn stop valves
471 19
Socket wrench
B5105 500 00 005
Handle for flush-mounted valves
590 00
Operating cover for flush-mounted valves
591 00
Fixing set UP-PLUS
597 00
UP-PLUS extension set
599 00