Precautions 

for installation, maintenance and operation

Use  

The KEMPER FROSTI

®

 is used as a 

frost-proof outdoor tap.  

Do not use the product for other  

purposes than described above. 

Any other uses constitute misuse.

Warnings

Be sure to read and follow the warn-

ings in the manual. Failing to do so 

can lead to personal injury or material 

damage!

Important warnings:

Warning! 

Highlights risks 

that may result in injury, ma-

terial damage or contamination 

of drinking water.

Note! 

Highlights risks that 

may result in damage to the 

plant or dysfunction.

 

Important advice to the operator

Medium: water

maximum operating temperature 90 °C, 

pressure rating PN 16  

1. The valve should only be used

  - in good order and condition

  - as intended

2. 

During periods prone to frost,    

  always separate the hose and    

  all screw connections from  

 

  the tap.

Maintenance

In accordance with BS EN 806-5, main-

tenance is to be carried out on the tap 

annually.

Be sure to comply with the local  

regulations on waste recycling  

and disposal.

Installation and operation 

Read the manual and follow the  

instructions before installation. 

Installation and maintenance must be 

carried out by qualified plumbers. 

 

Provide manual to the plant operator 

and keep on hand for further reference!

The place of installation may not be at 

risk of flooding.

Perform a leak test after installation 

and before commissioning!

Priority must be given to the national 

standards and provisions on sanitary 

installations and accident prevention. 

All dimension specifications are given  

in mm.

Warranty 

 

No warranty in case of:

- Non-compliance with the manual.

- Damage due to incorrect installation.

- Unauthorised modification of the product.

Содержание 577 11

Страница 1: ...D R I V I N G P R O G R E S S Installation and Operating Manual Frost proof outdoor tap FROSTI Fig 577 11 ...

Страница 2: ...ition as intended 2 During periods prone to frost always separate the hose and all screw connections from the tap Maintenance In accordance with BS EN 806 5 main tenance is to be carried out on the tap annually Be sure to comply with the local regulations on waste recycling and disposal Installation and operation Read the manual and follow the instructions before installation Installation and main...

Страница 3: ...n FR Fermer la robinet sans effort l eau coule encore pendant 10 secondes CS Stačí jen lehké oto čení po 10 vte řina odtoku vody v po řádku i i 4 10 1 5 7 3 2 9 6 8 11 Item Designation Art No 1 breather E21055730000100 2 locking bush L11005900000100 3 hose coupling Z21005741601500 4 head part E010557401015KP 5 collar L41055770101500 6 screw D31209990100200 7 PE gasket C31005740000200 8 socket key ...

Страница 4: ...4 12 K410057700003 00 09 2018 www kemper olpe de max 2 min 27 max 2 min 27 i a b ...

Страница 5: ...o loop the tap in the drinking water system For technical and hygienic reasons it is necessary to install the last min 100 mm and max 10 x DN as a functional individual supply line The tap must be installed at least 250 mm above the maximum fluid level Warning The FROSTI must be installed in accord ance to Water Regulations schedule 2 paragraph 15 The level of protection must be appropriate to the...

Страница 6: ...6 12 K410057700003 00 09 2018 www kemper olpe de 1 2 1 2 ...

Страница 7: ...7 12 K410057700003 00 09 2018 www kemper olpe de 0 C 0 C 100 5 3 4 ...

Страница 8: ...8 12 K410057700003 00 09 2018 www kemper olpe de 2x 2x 7 6 1 2 1 3 2 ...

Страница 9: ...9 12 K410057700003 00 09 2018 www kemper olpe de 3 2x 8 2 1 ...

Страница 10: ...10 12 K410057700003 00 09 2018 www kemper olpe de 1 2 2 A B 1 2 3 10 9 ...

Страница 11: ...11 12 K410057700003 00 09 2018 www kemper olpe de FROSTI č če ní ř řá dk u i 1 5 6 4 3 Fig 575 00 003 2 11 ...

Страница 12: ...lpe de K410057700003 00 09 2018 i i Phone 44 16 84 85 49 30 Fax 44 16 84 85 49 31 www kemper uk com info kemper uk com D R I V I N G P R O G R E S S Kemper UK Ireland Ltd 2 Ripple Court Brockeridge business park Twyning Tewkesbury Glos GL20 6FG ...

Отзывы: