Installation Instructions

Horizon Natural Draft Electronic Ignition

Gas Fireplaces

Содержание Horizon Natural Draft Electronic Ignition

Страница 1: ...Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces...

Страница 2: ...Ignition Gas Fireplace DATA PLATE Refer to data plate for information in respect to gas pressure consumption and gas type Natural or LPG Data Plate is located under the gas burner and is accessed by...

Страница 3: ...pellet Kemlan recommends that all gas fires be serviced every year All gas units must be fitted by a licensed gas fitter It is the responsibility of the gas fitter to follow the regulations set out i...

Страница 4: ...CONNECTION UNDER BURNER Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Measurement and Specifications of N D E I SINGLE SIDED CANTILEVER DOUBLE SIDED UNDER BURNER U...

Страница 5: ...5 Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Framing Dimensions DOUBLE SIDED SINGLE SIDED B INCLUDE 10MM PLASTERBOARD...

Страница 6: ...6 Installation Instructions Kemlan Natural Draft Electronic Ignition Gas Fireplaces Section SINGLE SIDED ELEVATION CANTILEVER ELEVATION SINGLE SIDED SECTION CANTILEVER SECTION Elevation...

Страница 7: ...pilot and main burner will then ignite from pilot Burner is turned off by turning off wall switch System does not have a high low burner switch Laying the fire Coal Pebble Evenly spread a bag of Vermi...

Страница 8: ...ireplaces Laying the fire Coal Pebble MARK 2 COALS 440 500 390 X 240 MARK 2 COALS 600 460 X 260 MARK 2 COALS 700 580 X 260 MARK 2 PEBBLES 700 580 X 260 MARK 2 COALS 700 800 600 X 155 MARK 2 PEBBLES 70...

Страница 9: ...s two holes on the underside to position in place 3 LOCATE LOG NO S 2 3 Two front log NO S 2 3 are supplied to fit into the space between the metal frame and the ceramic base These logs do not cover t...

Страница 10: ...log is placed on the rear log in the centre of the burner Charred effect facing toward the left of the burner The front rests on logs 2 3 on the join LOCATE LOG NO 10 This log is located on the rear l...

Страница 11: ...og no s 2 and 3 are supplied to fit into the space between the metal frame and the ceramic base These logs do not cover the front burner ports but are designed to deflect the front flame back into the...

Страница 12: ...large rear log no 1 6 LOCATE LOG NO 7 The charred effect of the log is positioned on the smaller coal in the centre of the burner on the right hand side The right hand side of the log is positioned be...

Страница 13: ...e ignition system Working correctly there will be no spillage Unit should cut out if not enough draw to ensure proper functioning 2 Initially the Kemlan coal fire may burn with a slightly blue flame A...

Страница 14: ...14 Wiring Diagram For further service information contact Kemlan Australia Head Office 59 Pineapple St Zillmere QLD 4034 Telephone 07 3263 8488 Facsimile 07 3263 6452 www kemlan com...