background image

KEMKRAFT

 

ENGINEERING, INC.

 

MODEL KEI-850A READOUT BOX 

 

96-036.doc

 

 

4

 

47650 Clipper Dr. Plymouth Twp., MICHIGAN  48170  (734)-414-6500 

 

After the switch is pressed, the display will instruct you to place the cal stand to the -45 

degree, than to -30 degrees etc. until +60 degrees is completed.  When the cal stand is placed 

in the +60 degree position and the CALIBRATE switch is pressed, the program will go back to 

RUN mode and the calibration procedure for that tool is finished.  The accuracy of the 

calibration can be checked in the RUN mode by placing the cal stand into various positions 

and observing the display values.  If only one tool is used, the calibration procedure is 

finished.  If two tools are being used, and the other tool needs calibration, repeat steps A 

through D for the second tool. 

 

 

 

* SETTING TOOL DISPLAY OFFSET*

 

 

 

A)  Install the desired Clear Vision steering wheel set tool onto a calibration stand which can 

be adjusted from +60 degrees to -60 degrees in 15 degree increments. 

 

B)  Press the CALIBRATION pushbutton switch once and the display will read. 

 

 

 

 

 

C)  DO NOT press CALIBRATION pushbutton again.  The display will read. 

 

 

 

 

 

 

This display shows the user what the current tool display offset value. 

 

Press the CALIBRATION pushbutton to change the offset value.  The display will read. 

 

 

 

 

 

D)  Press the CALIBRATION pushbutton to cycle from +5.00 to –5.00 degrees in 0.50 degree 

increments.  Stop pressing the CALIBRATION pushbutton to set value. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAL sw again=CAL

 

Timeout = offset

 

CAL SWITCH = OFFSET

 

X.XX deg offset

 

X.XX deg. OFFSET

 

TIMEOUT WILL SET

 

Содержание KEI-850A

Страница 1: ...NEERING INC MODEL KEI 850A READOUT BOX 96 036 doc 1 47650 Clipper Dr Plymouth Twp MICHIGAN 48170 734 414 6500 INSTRUCTION MANUAL CLEAR VISION DUAL INCLINOMETER BOX MODEL KEI 850A GM TRUCK BUS REVISION DATE 25 MAY 00 ...

Страница 2: ...sure This power switch also doubles as a circuit breaker for the KEI 850A Display box Should the breaker ever trip the power switch only needs to be turned to the off position and back on to reset the breaker B After the power has been applied to the KEI 850A Display box the LCD display will have this display C Place the TOOL on the steering wheel The display will read the following D Follow the d...

Страница 3: ...ead Press CAL switch again to calibrate If a calibration procedure is to be performed press the CAL switch a second time and the program will go into the cal procedure If the cal procedure is not desired a countdown timer will countdown for 15 seconds and the program will go back to the RUN MODE The red LED should turn off and the green LED should turn back on D If calibration is desired press the...

Страница 4: ...e is finished If two tools are being used and the other tool needs calibration repeat steps A through D for the second tool SETTING TOOL DISPLAY OFFSET A Install the desired Clear Vision steering wheel set tool onto a calibration stand which can be adjusted from 60 degrees to 60 degrees in 15 degree increments B Press the CALIBRATION pushbutton switch once and the display will read C DO NOT press ...

Страница 5: ...ctor is set up for three wire RS 232 interface ground transmit and receive Connections Protocol Dump String are the same as Burke Porter The only difference is that the angle is transmitted every time the KEI 850B box receives a Control E E is for inquire REMOTE COMMUNICATION PORT This Amphenol connector Comm 2 is used for communicating to a KEI 325RD remote display unit or allows two KEI 850 Digi...

Отзывы: