background image

KEMKRAFT

 

ENGINEERING, INC.

 

MODEL KEI-850A READOUT BOX 

 

96-036.doc

 

 

2

 

47650 Clipper Dr. Plymouth Twp., MICHIGAN  48170  (734)-414-6500 

 

*

 

INSTALLATION

 

INSTRUCTIONS

 

*

 

 

A)  The KEI-850A Display box should be permanently installed in a location that is best for the 

application.  It is usually mounted straight out the drivers side window on a pedestal stand. 

 

B)  When the box is installed, place a vehicle in the alignment machine and install the 

mechanical fixture onto the steering wheel.  Ensure that the KEI-850A display box can be 

easily viewed while loading an Unfixtured Clear Vision Tool onto a steering wheel.

 

 

 

* OPERATING

 

INSTRUCTIONS

 

*

 

 

NOTE: As always, these Steering Wheel Gauges are delicate, accurate, gauging tools 

that need to be treated as such and therefore must be installed in a holder when 

not in use.  If these tools do not have a holder & are thrown down on a table 

during use, the warranty will be void. 

 

A)  Apply power to the KEI-850A by turning on the power switch located on the bottom left part 

of the enclosure.  This power switch also doubles as a circuit breaker for the KEI-850A 

Display box.  Should the breaker ever trip the power switch only needs to be turned to the 

off position and back on to reset the breaker. 

 

B)  After the power has been applied to the KEI-850A Display box the LCD display will have 

this display. 

 

 

 

 

C)  Place the TOOL on the steering wheel.  The display will read the following. 

 

 

 

 

 

D)  Follow the display instructions and rotate the steering wheel to 90 degrees.  The display 

will now display the following. 

 

 

 

 

 

E)  Follow the display instructions and bring the TOOL back to 0.00 Deg.  The display will start 

to read out the steering angle starting at 30.0 degrees.  

The program will jump back to 

the start of the cycle if the SWG is rotated CCW past -5.00 degrees.  

This is the 

purpose of this whole procedure, to always bind all of the hysteresis CW.

   

 

F)  If the KEI-850A displays the following message, the calibration data is bad and the unit 

needs to be calibrated. 

 

 

 

 

G)  Note: The 850A Box is interfaced to the Alignment Machines’ PLC to control the 

SWGs’ vertical pneumatic cylinder.  

 

PLACE TOOL ON

 

STRNG WHL or CAL

 

ROTATE STRNG WHL

 

90 deg CLOCKWISE

 

BRING SW BACK TO

 

0 deg & LOCK POGO

 

MEMORY ERROR

 

CALIBRT TOOL NOW

 

Содержание KEI-850A

Страница 1: ...NEERING INC MODEL KEI 850A READOUT BOX 96 036 doc 1 47650 Clipper Dr Plymouth Twp MICHIGAN 48170 734 414 6500 INSTRUCTION MANUAL CLEAR VISION DUAL INCLINOMETER BOX MODEL KEI 850A GM TRUCK BUS REVISION DATE 25 MAY 00 ...

Страница 2: ...sure This power switch also doubles as a circuit breaker for the KEI 850A Display box Should the breaker ever trip the power switch only needs to be turned to the off position and back on to reset the breaker B After the power has been applied to the KEI 850A Display box the LCD display will have this display C Place the TOOL on the steering wheel The display will read the following D Follow the d...

Страница 3: ...ead Press CAL switch again to calibrate If a calibration procedure is to be performed press the CAL switch a second time and the program will go into the cal procedure If the cal procedure is not desired a countdown timer will countdown for 15 seconds and the program will go back to the RUN MODE The red LED should turn off and the green LED should turn back on D If calibration is desired press the...

Страница 4: ...e is finished If two tools are being used and the other tool needs calibration repeat steps A through D for the second tool SETTING TOOL DISPLAY OFFSET A Install the desired Clear Vision steering wheel set tool onto a calibration stand which can be adjusted from 60 degrees to 60 degrees in 15 degree increments B Press the CALIBRATION pushbutton switch once and the display will read C DO NOT press ...

Страница 5: ...ctor is set up for three wire RS 232 interface ground transmit and receive Connections Protocol Dump String are the same as Burke Porter The only difference is that the angle is transmitted every time the KEI 850B box receives a Control E E is for inquire REMOTE COMMUNICATION PORT This Amphenol connector Comm 2 is used for communicating to a KEI 325RD remote display unit or allows two KEI 850 Digi...

Отзывы: