
Kelvinator Air Conditioning
Installation instructions 13
caution
1. The insulating tube should be connected reliably with the
sleeve outside the outlet pipe.
2. The drain hose should be slanted downward slightly, without
distortion, bulge or fluctuation.
do not block water
flow with a rise
do not put the end
of the hose in water
3. Do not put the outlet in the water.
bulge
flooded
The piping can be output from right, rear right, left or
rear left of the indoor unit body.
1. When routing the piping and wiring from the left or right
side of indoor unit, cut off the tailings from the chassis when
necessary (see figure below).
tailing 2
tailing 1
• Cut off the tailings 1 when routing the wiring only.
• Cut off the tailings 1 and tailings 2 when routing both the wiring
and piping.
indoor unit outline
connection piping
43
2. The drain hose can be connected at two different positions.
Use the most convenient position and, if necessary, exchange
the position of drain cap and drain hose.
• The drain hose is connected at the rear left side of the indoor
unit when you receive the product.
drain hose
(connected at the
rear left side)
refrigerant
piping
drain hole
drain cap
Follow the instructions below for exchanging the position of the
drain cap and drain hose from the left to the right side.
a. Pull out the drain cap at the rear right of the
indoor unit.
drain cap
b. Pull out the drain hose at the rear left of the
indoor unit.
drain hose
c. Put the drain cap into the drain hole at the rear left of the
indoor unit.
drain cap
Indoor unit installation
Содержание KSV26CRE
Страница 26: ...26 Notes Kelvinator Air Conditioning Notes ...