Kelvinator KSV26CRC Скачать руководство пользователя страница 9

Kelvinator Air Conditioning 

Features of the remote contol  5

 

In Heat mode

 

(1)  When the initial temperature is set at 16°C, the air 

conditioner  will continue to run at this setting.

 

(2)  When the initial temperature is set at between 

17°C-20°C, after Sleep function is selected, the set 
temperature will decrease 1°C at the end of the first 
hour and continue to run at this setting.

 

(3)  When the initial temperature is set between

 

21°C-27°C, after this Sleep function is selected, 
the temperature will decrease 1°C in every hour, 
after 2 hours the air conditioner will continue to 
run at this setting.

 

(4)  When the initial temperature is set between

 

28°C-30°C, after this Sleep function is selected 
the temperature will decrease 1°C in every hour, 
after 3 hours the air conditioner will continue to run 
at this setting.

 

Sleep Mode 3

 

 In this mode the sleep temperature curve is manually 
set (DIY).

 

(1)  After selecting Sleep mode 3, press and hold the 

Turbo button until the remote control enters into 
user defined sleep setting status. The remote control 
will display "1 hour", temperature display will show  
the corresponding temperature of last setting sleep 
curve and blink (The first use will display the original 
factory setting).

 

(2)  Adjust " " and " " buttons will change the setting 

temperature  for the first hour of sleep, after 
setting the temperature, press the Turbo button 
for confirmation.

 

(3)  The hour of sleep mode  will be automatically 

increased on the remote  control, to the 2nd, 3rd hour 
of sleep mode and so on with each press of the 
Turbo button.

 

(4)  Repeat the above step (2 )-(3) operation, until 8 hours 

of sleep temperature setting is finished. The sleep 
curve program is finished The remote control will 
resume the original timer display. The  temperature 
display will return to the original setting.

 

 The sleep program can be checked by selecting sleep 
mode 3, pressing and holding the Turbo button and 
then repeat pressing the turbo button to review the 
sleep program temperatures without pressing the " " 
or " " buttons. In this mode, if the no button were to 
be pressed for 10 seconds, the display will revert to 
normal operation.

10  I FEEL Button

 

 Press this button once, to turn on the I FEEL 
function, then the symbol of "I FEEL" will be displayed. 
The air conditioner will then operate to reach the set 
temperature at the location of the remote control. 
After this function has started, the remote control will 
send temperature to the main unit every 10 minutes. 
Once the button has been pressed again, the function 
will be cancelled.

11  QUIET Button

 

 During operation press the Quiet button in order to use 
the Quietest fan mode in AUTO, COOL, DRY, FAN or 
HEAT mode.

12  SLEEP Button

 

 Pressing this button to select sleep mode (   ), 
sleep mode (   ), Sleep mode (   ) and cancel the 
Sleep mode. Circulate between these modes after 
the air conditioner is switched on.

 

Sleep mode 1

 

 In Cool and Dry modes, the set temperature will  
increase 1°C after an hour, after 2 hours the set 
temperature will increase another 1°C, then continue to 
run at this setting. In Heat mode: the set temperature 
will decrease 1°C, after 2 hours the set temperature 
will decrease another 1°C,  then continue to run at 
this setting.

 

Sleep mode 2

 

 In this mode, the air conditioner will run according to a 
preset sleep temperature curve.

 

In Cool mode

 

(1)  When setting the initial temperature between 

16-23°C, after turning on the Sleep function, the 
temperature will increase 1°C every hour, after 3°C 
the temperature will be maintained, after 7 hours, the 
temperature will be decreased a further 1°C, after that 
the unit will keep running at this temperature;

 

(2)  When setting the initial temperature between 

24°C-27°C, after turning on the Sleep function, the 
temperature will increase 1°C in every hour, after 2°C 
the temperature will be maintained, after 7 hours, the 
temperature will be decreased a further 1°C, after 
that the unit will keep running at this temperature;

 

(3)  When setting the initial temperature between 

28°C-29°C, after turning on the Sleep function, the 
temperature will increase 1°C in the first hour, after 
7 hours, the temperature will be decreased a further 
1°C, after that the unit will keep running at this 
temperature;

 

(4)  When setting the initial temperature to 30°C, after 7 

hours the temperature will be decreased 1°C, after 
that the unit will keep running at this temperature.

Содержание KSV26CRC

Страница 1: ...Inverter Split Room Air Conditioner User Manual KSV26CRC KSV26HRC KSV35CRC KSV35HRC KSV53HRC KSV62HRC KSV70CRC KSV70HRC KSV80HRC Refrigerant R410A ...

Страница 2: ...thorised personnel only Conditions of use This appliance is intended to be useed in household and similar applications such as Staff kitchen areas in shops offices and other working environments Farm houses By clients in hotels motels and other residential type environments Bed and breakfast type environments Contents i Quickstart guide ii Parts identification iii Safety precautions 1 Warning 1 Ca...

Страница 3: ...aneously to lock or unlock the keyboard If the remote control is locked the icon will be displayed on it in which case press any button the mark will flicker three times If the keyboard is unlocked the mark will disappear Switch between Centigrade and Farenheit With the air conditinioner switched off press the SWING H and ION FILTER buttons simultaneously to switch between C and F Energy saving Pr...

Страница 4: ...ont panel 4 Filter 5 Horizontal louver 6 Wall pipe 7 Binding tape 8 Connection pipe 9 Drain hose 10 Drain connector 11 Indoor display when active Outdoor unit Air in Air in 11 Air out Air out Name of parts iii Name of parts Kelvinator Air Conditioning Th w P fo 1 2 3 4 5 ...

Страница 5: ...installation manual Please ensure that the power supply to the air conditioner is stable and meets the requirements set out in the installation manual Always ensure the product is installed with appropriate earthing For safety be sure to turn off the circuit breaker before performing any maintenance or cleaning or when the product is not used for an extended period of time Accumulated dust may cau...

Страница 6: ...will flicker for about 1 second on the display The indoor unit will acknowledge the signal with a beep when it receives an effective signal caution The air conditioner will not operate if curtains doors or other materials block the signals from the remote control to the indoor unit Prevent any liquid from falling into the remote control Do not expose the remote control to direct sunlight or heat I...

Страница 7: ...g more quickly Maximum setting is 30 C 5 Button Pressing this button will decrease the temperature setting holding the button down for 2 seconds and more will decrease the temperature setting more The minimum setting is 16 C 2 1 3 4 5 1 ON OFF Button Press this button the unit will be turned on press it once more the unit will be turned off Sleep function will be cancelled while the unit is switch...

Страница 8: ...s and the ON symbol will display permanently Default times for timer on and off are 8 00am and 5 00pm 7 TIME OFF Button Press this key to enter into TIMER OFF setup in which case the OFF icon will blink The method of setting is the same as for TIMER ON 8 SWING V Button Press this button to enable or disable the vertical swing function When disabling the vertical swing function the guiding louver w...

Страница 9: ...seconds the display will revert to normal operation 10 I FEEL Button Press this button once to turn on the I FEEL function then the symbol of I FEEL will be displayed The air conditioner will then operate to reach the set temperature at the location of the remote control After this function has started the remote control will send temperature to the main unit every 10 minutes Once the button has b...

Страница 10: ...es not operate normally please remove and refit the batteries If abnormal operation continues replace with new batteries To operate the air conditioner please point the remote control at the indoor unit in order to improve the sensitivity of the main unit 1 3 4 2 Fig 1 Fig 2 When the remote control is lost or damaged please use the manual switch on the main unit In that case the unit will operate ...

Страница 11: ... before cleaning and maintenance Do not splash water on the units for cleaning as electric shocks may occur Wipe the units with a dry soft cloth or a cloth slightly moistened with water or cleaner not with volatile liquid such as thinner or gasoline Cleaning the Front Panel Remove the front panel Then wipe the front panel with a soft cloth moistened with water to remove any marks Note Do not immer...

Страница 12: ...48 26 Minimum cooling 21 15 21 Maximum heating 27 24 18 Minimum heating 20 5 6 The operating temperature range outdoor temperature for cooling only unit is 16 C 48 C for heat pump unit is 15 C 24 C Tips for energy saving Do not overcool or overheat Setting temperature at a moderate level helps energy saving Cover windows with a blind or a curtain Blocking sunlight and air from outdoors is favourab...

Страница 13: ...wer plug is overheating The air conditioner is not user serviceable Incorrect repair may cause electric shock or fire so please contact an authorised service center for professional repair The following checks prior to contact may save you time and money Problem Cause The unit does not operate The unit does not operate if it is turned on immediately after it is turned off This is to protect the un...

Страница 14: ...10 notes Kelvinator Air Conditioning Notes ...

Страница 15: ...Kelvinator Air Conditioning notes 11 Notes ...

Страница 16: ...e without special equipment Has the appropriate size circuit and fuse circuit breaker been fitted Has the unit been tested and confirmed to operate correctly Has the user of the air conditioner been shown how to use the air conditioner CUSTOMER PLEASE RETAIN WITH YOUR PURCHASE DOCUMENTS IN A SAFE PLACE Model Number ___________________________________________________________________________________...

Страница 17: ...ore you can make a claim under this warranty 7 You may not make a claim under this warranty unless the defect claimed is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive a the Appliance is damaged by i accident ii misuse or abuse including failure to properly maintain or service iii normal wear and tear iv power surges el...

Страница 18: ...on about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux com au web www kelvinator com au Kelvinator We are part of the Electrolux family Share more of our thinking at www electrolux com au ...