Kelvinator KSV26CRC Скачать руководство пользователя страница 13

Kelvinator Air Conditioning 

Troubleshooting  9

Problem

Cause

Water leakage of 
outdoor unit

•  During cooling operation, water 

condensates around the pipes and 
connection joints.

•  During defrosting operation, thawed 

water flows out.

•  During heating operation, water on the 

heat exchanger drips out.

Noise from indoor 
unit.

•  The noise emitted when the fan or 

compressor relay is switched on or off.

•  When the defrosting operation

 

is started or stopped, there is a 
sound of refrigerant flowing in the 
reverse direction.

Indoor unit can not 
blow air

•  In HEAT mode, when the temperature

 

of indoor heat exchanger is very low, 
air flow is stopped in order to prevent 
cold air. (within 2 minutes)

•  In HEAT mode, when the outdoor 

temperature is low or humidity is high, 
frost will be formed on the outdoor 
heat exchanger. The unit will defrost 
automatically and indoor unit will stop 
blowing air for 3-12 minutes.

•  During defrosting operation, water or 

vapour may be emitted.

•  In DRY mode, the indoor fan will stop 

blowing air for 3-12 minutes in order 
to avoid condensing water being 
vaporised again.

Moisture on air 
outlet

•  If the unit operates at high humidity for a 

long time, moisture will be generated on 
the air outlet grill and then drip off.

H1: Defrosting

It is normal. The unit is in defrosting mode 
and heating will recommence soon.

E3: Low pressure 
warning

Your air conditioner has lost refrigerant. 
Contact your installer to check for 
potential leaks.

The pressure in the refrigeration system is low and could result 
in the unit breaking down. Ask a certified installer to control it.
If any one of the following situations occurs, immediately stop 
all operations, disconnect the power supply, and contact the 
authorised personnel.

•  There is a harsh sound during operation.
•  Strong odours are emitted during operation.
•  Water is leaking from the unit.
•  The circuit breaker often trips.
•  Water or other liquid is splashed into the unit.
•  Power cord and power plug is overheating.

The air conditioner is not user serviceable. Incorrect repair 
may cause electric shock or fire, so please contact an 
authorised service center for professional repair.
The following checks prior to contact may save you time 
and money.

Problem

Cause

The unit does not 
operate

The unit does not operate if it is 
turned on immediately after it is 
turned off. This is to protect the unit. 
You should wait about 3 minutes.

Odours are emitted

•  Some odours may be emitted 

from the indoor unit. This is the 
result of room smells (such as 
furniture,tobacco,etc.) which have 
been taken into the air conditioner.

•  Consult authorised service centre for 

cleaning if the odours persist.

"Water flowing" noise

The swishing noise like water flowing is 
the refrigerant flowing inside the unit.

Mist is emitted in 
COOL mode

During cooling operation, a thin mist 
may be seen emitted from the indoor 
unit due to high room temperature 
and humidity.
After a period of time, the mist will 
disappear as the decrease of room 
temperature and humidity decreases.

Cracking noise

This is the sound of friction caused 
by expansion and/or contraction of 
panel or other parts due to the change 
of temperature.

The unit can not be 
started up

• Is the power cut off?
•  Is the power plug loose?

 

(if applicable )

•  Is the circuit protection device 

tripped off?

•  Is voltage higher or lower? 

 

(Tested by professionals)

• Is the TIMER correctly used?

Cooling/Heating 
effect is poor

• Is temperature setting appropriate?
• Is the inlet or outlet blocked?
• Is the filter dirty?
• Is the window or the door open?
• Is low fan speed set?
• Are there heat sources in the room?

Remote control does 
not transmit signals

•  Check if there is magnetic or 

electrical interference near the unit 
that may affecting operation of the 
remote control. In this case, pull the 
plug out and reinsert it.

•  Is the remote control within its 

operating range or obstructed? 

Check the condition of the batteries 
and replace them if necessary.

•  Check if the remote control

 

is damaged.

Water leakage of 
indoor unit

• The humidity is high.
• Condensing water overflows.
• Drain hose is loose or obstructed.

Troubleshooting

Содержание KSV26CRC

Страница 1: ...Inverter Split Room Air Conditioner User Manual KSV26CRC KSV26HRC KSV35CRC KSV35HRC KSV53HRC KSV62HRC KSV70CRC KSV70HRC KSV80HRC Refrigerant R410A ...

Страница 2: ...thorised personnel only Conditions of use This appliance is intended to be useed in household and similar applications such as Staff kitchen areas in shops offices and other working environments Farm houses By clients in hotels motels and other residential type environments Bed and breakfast type environments Contents i Quickstart guide ii Parts identification iii Safety precautions 1 Warning 1 Ca...

Страница 3: ...aneously to lock or unlock the keyboard If the remote control is locked the icon will be displayed on it in which case press any button the mark will flicker three times If the keyboard is unlocked the mark will disappear Switch between Centigrade and Farenheit With the air conditinioner switched off press the SWING H and ION FILTER buttons simultaneously to switch between C and F Energy saving Pr...

Страница 4: ...ont panel 4 Filter 5 Horizontal louver 6 Wall pipe 7 Binding tape 8 Connection pipe 9 Drain hose 10 Drain connector 11 Indoor display when active Outdoor unit Air in Air in 11 Air out Air out Name of parts iii Name of parts Kelvinator Air Conditioning Th w P fo 1 2 3 4 5 ...

Страница 5: ...installation manual Please ensure that the power supply to the air conditioner is stable and meets the requirements set out in the installation manual Always ensure the product is installed with appropriate earthing For safety be sure to turn off the circuit breaker before performing any maintenance or cleaning or when the product is not used for an extended period of time Accumulated dust may cau...

Страница 6: ...will flicker for about 1 second on the display The indoor unit will acknowledge the signal with a beep when it receives an effective signal caution The air conditioner will not operate if curtains doors or other materials block the signals from the remote control to the indoor unit Prevent any liquid from falling into the remote control Do not expose the remote control to direct sunlight or heat I...

Страница 7: ...g more quickly Maximum setting is 30 C 5 Button Pressing this button will decrease the temperature setting holding the button down for 2 seconds and more will decrease the temperature setting more The minimum setting is 16 C 2 1 3 4 5 1 ON OFF Button Press this button the unit will be turned on press it once more the unit will be turned off Sleep function will be cancelled while the unit is switch...

Страница 8: ...s and the ON symbol will display permanently Default times for timer on and off are 8 00am and 5 00pm 7 TIME OFF Button Press this key to enter into TIMER OFF setup in which case the OFF icon will blink The method of setting is the same as for TIMER ON 8 SWING V Button Press this button to enable or disable the vertical swing function When disabling the vertical swing function the guiding louver w...

Страница 9: ...seconds the display will revert to normal operation 10 I FEEL Button Press this button once to turn on the I FEEL function then the symbol of I FEEL will be displayed The air conditioner will then operate to reach the set temperature at the location of the remote control After this function has started the remote control will send temperature to the main unit every 10 minutes Once the button has b...

Страница 10: ...es not operate normally please remove and refit the batteries If abnormal operation continues replace with new batteries To operate the air conditioner please point the remote control at the indoor unit in order to improve the sensitivity of the main unit 1 3 4 2 Fig 1 Fig 2 When the remote control is lost or damaged please use the manual switch on the main unit In that case the unit will operate ...

Страница 11: ... before cleaning and maintenance Do not splash water on the units for cleaning as electric shocks may occur Wipe the units with a dry soft cloth or a cloth slightly moistened with water or cleaner not with volatile liquid such as thinner or gasoline Cleaning the Front Panel Remove the front panel Then wipe the front panel with a soft cloth moistened with water to remove any marks Note Do not immer...

Страница 12: ...48 26 Minimum cooling 21 15 21 Maximum heating 27 24 18 Minimum heating 20 5 6 The operating temperature range outdoor temperature for cooling only unit is 16 C 48 C for heat pump unit is 15 C 24 C Tips for energy saving Do not overcool or overheat Setting temperature at a moderate level helps energy saving Cover windows with a blind or a curtain Blocking sunlight and air from outdoors is favourab...

Страница 13: ...wer plug is overheating The air conditioner is not user serviceable Incorrect repair may cause electric shock or fire so please contact an authorised service center for professional repair The following checks prior to contact may save you time and money Problem Cause The unit does not operate The unit does not operate if it is turned on immediately after it is turned off This is to protect the un...

Страница 14: ...10 notes Kelvinator Air Conditioning Notes ...

Страница 15: ...Kelvinator Air Conditioning notes 11 Notes ...

Страница 16: ...e without special equipment Has the appropriate size circuit and fuse circuit breaker been fitted Has the unit been tested and confirmed to operate correctly Has the user of the air conditioner been shown how to use the air conditioner CUSTOMER PLEASE RETAIN WITH YOUR PURCHASE DOCUMENTS IN A SAFE PLACE Model Number ___________________________________________________________________________________...

Страница 17: ...ore you can make a claim under this warranty 7 You may not make a claim under this warranty unless the defect claimed is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive a the Appliance is damaged by i accident ii misuse or abuse including failure to properly maintain or service iii normal wear and tear iv power surges el...

Страница 18: ...on about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux com au web www kelvinator com au Kelvinator We are part of the Electrolux family Share more of our thinking at www electrolux com au ...

Отзывы: