Kelvinator KSV25HRD Скачать руководство пользователя страница 2

2

Contents

Congratulations and thank you for choosing our 

Inverter Speed 

Split room

 air conditioner. We are sure you will find  

your new air conditioner a pleasure to use. Before you use the air 
conditioner, we recommend that you read through  
the entire user manual, which provides the description of  
the air conditioner and its functions.

To avoid the risks that are always present when you use an electrical 
appliance, it is important that the air conditioner  
is installed correctly and that you read the safety instructions 
carefully to avoid misuse and hazards.

We recommend that you keep this instruction booklet  
for future reference and pass it on to any future owners.

After unpacking the air conditioner please check it is not damaged. 
If in doubt, do not use the air conditioner but  
contact your local Electrolux Customer Care Centre.

ENVIRONMENTAL TIPS

 environment

Information on disposal for users

•    Most of the packing materials are recyclable.  

Please dispose of those materials through your local recycling 
depot or by placing them in appropriate collection containers.

•    If you wish to discard this air conditioner, please contact your 

local authorities and ask for the correct method  
of disposal.

Conditions of use

This appliance is intended to be used in household and similar 
applications such as:

•    Staff kitchen areas in shops, offices and other working 

environments

•   Farm houses

•    By clients in hotels, motels, and other residential 

type environments

•   Bed and breakfast type environments

Contents  ...................................................................... 2

Safety precautions ....................................................... 3

Notice for installation .................................................. 4

Installation drawing ..................................................... 5

Installation of indoor unit ............................................. 6

Refrigerant pipe connection  ........................................ 8 

Installation of outdoor unit .......................................... 9

Check after installation and operation test ................ 10

Installation and Maintenance of HEPA Filter .............. 10

Warranty .................................................................... 11

Congratulations

Contents

Содержание KSV25HRD

Страница 1: ...Inverter Split Room Air Conditioner Installation Manual KSV25HRD KSV35HRD KSV52HRD KSV70HRD KSV80HRD Refrigerant R410A ...

Страница 2: ...your local Electrolux Customer Care Centre ENVIRONMENTAL TIPS environment Information on disposal for users Most of the packing materials are recyclable Please dispose of those materials through your local recycling depot or by placing them in appropriate collection containers If you wish to discard this air conditioner please contact your local authorities and ask for the correct method of dispos...

Страница 3: ...responsible for their safety 7 Children should be supervised to ensure that they do not play with the appliance WARNING warning Before obtaining access to terminals all supply circuits must be disconnected Please read this installation manual and the user manual before installation and carefully store in a handy place for later reference Inside you will find many helpful hints on how to install an...

Страница 4: ...ent welders or medical equipment salt laden air prevails such as close to coastal areas the air is contaminated with industrial vapours and oils the air contains sulphurous gas such as in hot spring zones corrosive or poor air quality exists Installation Site of Indoor Unit 1 The air inlet and outlet should be away from the obstructions Ensure the air can be blown through the whole room 2 Select a...

Страница 5: ... adhered to the air conditioner will not perform to specification may not be able to be serviced and the warranty may be voided The installation must allow for reasonable access by a service technician space necessary for proper installation of the unit with respect to existing building structure Space to the wall 150cm horizontally in front Space to the obstruction Air outlet side e v o b 50cm A ...

Страница 6: ...he outlet in the water Installation of indoor unit Installation of Mounting Plate 1 The mounting plate should be installed horizontally As the water tray s outlet for the indoor unit is two way type during installation the indoor unit should slightly slant to water tray s outlet for smooth drainage of condenser water 2 Fix the mounting plate on the wall with screws 3 Be sure that the mounting plat...

Страница 7: ... of indoor unit cut off the tailings from the chassis when necessary As shown in Fig 1 a Cut off the tailings 1 when routing the wiring only b Cut off the tailings 1 and tailings 2 when routing both the wiring and piping 2 Take out the piping from body case wrap the piping power cords drain hose with the tape and then make them pass through the piping hole As shown in Fig 2 3 Hang the mounting slo...

Страница 8: ...move flare nuts attached to indoor and outdoor unit then put them on pipe tube having completed burr removal Note It is not possible to put them on after flaring work Flare nut Copper tube D Flaring work Carry out flaring work using flaring tool as shown below Firmly hold copper pipe in a die according to the dimension shown in the table below Refrigerant pipe connection Outer diam mm A mm Max Min...

Страница 9: ...kage Test 1 Connect charging hose of manifold valve to charge end of low pressure valve both high low pressure valves must be tightly shut 2 Connect joint of charging hose to vacuum pump 3 Fully open the handle of Lo manifold valve 4 Open the vacuum pump for vacuumisation At the beginning slightly loosen joint nut of low pressure valve to check if there is air coming inside If noise of vacuum pump...

Страница 10: ...t accurate Operation Test 1 Before Operation Test a Do not switch on power before installation is finished completely b Electric wiring must be connected correctly and securely c Cut off valves of the connection pipes should be opened d All the impurities such as scraps and waste must be cleared from the unit 2 Operation Test Method a Switch on power and press ON OFF button on the remote controlle...

Страница 11: ...hown in the fig For 5 2kW is as below Clasp of RJ45 plug of network cable shall aim at the notch of RJ45 terminal to be installed The clasp shall be towards inside as shown in the fig For 7 0kW and 8 0kW is as below Clasp of RJ45 plug of network cable shall aim at the notch of RJ45 terminal to be installed The clasp shall be towards left as shown in the fig Bundle the Dred network cable at the wir...

Страница 12: ...12 Notes Notes ...

Страница 13: ...13 Notes Notes ...

Страница 14: ...14 Notes Notes ...

Страница 15: ...ct claimed is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive a the Appliance is damaged by i accident ii misuse or abuse including failure to properly maintain or service iii normal wear and tear iv power surges electrical storm damage or incorrect power supply v incomplete or improper installation vi incorrect improper...

Страница 16: ...nator com au NEW ZEALAND phone 0800 436 245 fax 0800 225 088 email customercare electrolux co nz web kelvinator co nz For more information on all Kelvinator appliances or for dimension and installation information call into your retailer phone or email our customer care team or visit our website Kelvinator We are part of the Electrolux family Share more of our thinking at electrolux com au ...

Отзывы: