Kelvinator KSV25HRD Скачать руководство пользователя страница 9

9

Remote control features

 

In Heat mode

 

(1)  When the initial temperature is set at 16°C, the air 

conditioner  will continue to run at this setting.

 

(2)  When the initial temperature is set at between 17°C-20°C, 

after Sleep function is selected, the set temperature will 
decrease 1°C at the end of the first hour and continue to 
run at this setting.

 

(3)  When the initial temperature is set between 

21°C-27°C, after this Sleep function is selected, 
the temperature will decrease 1°C in every hour, 
after 2 hours the air conditioner will continue to 
run at this setting.

 

(4)  When the initial temperature is set between 

28°C-30°C, after this Sleep function is selected 
the temperature will decrease 1°C in every hour, 
after 3 hours the air conditioner will continue to run 
at this setting.

 

Sleep Mode 3

 

 In this mode the sleep temperature curve is manually 
set (DIY).

 

(1)  After selecting Sleep mode 3, press and hold the Turbo 

button until the remote control enters into 
user defined sleep setting status. The remote control 
will display "1 hour", temperature display will show  the 
corresponding temperature of last setting sleep curve and 
blink (The first use will display the original factory setting).

 

(2)  Adjust " " and " " buttons will change the setting 

temperature  for the first hour of sleep, after 
setting the temperature, press the Turbo button 
for confirmation.

 

(3)  The hour of sleep mode  will be automatically increased on 

the remote  control, to the 2nd, 3rd hour of sleep mode and 
so on with each press of the 
Turbo button.

 

(4)  Repeat the above step (2 )-(3) operation, until 8 hours of 

sleep temperature setting is finished. The sleep curve 
program is finished The remote control will resume the 
original timer display. The  temperature display will return to 
the original setting.

 

 The sleep program can be checked by selecting sleep mode 3, 
pressing and holding the Turbo button and 
then repeat pressing the turbo button to review the sleep 
program temperatures without pressing the " " or " " 
buttons. In this mode, if the no button were to 
be pressed for 10 seconds, the display will revert to normal 
operation.

10  I FEEL Button

 

 Press this button once, to turn on the I FEEL 
function, then the symbol of "I FEEL" will be displayed. The air 
conditioner will then operate to reach the set temperature at 
the location of the remote control. 
After this function has started, the remote control will send 
temperature to the main unit every 10 minutes. 
Once the button has been pressed again, the function will be 
cancelled.

11  QUIET Button

 

 During operation press the Quiet button in order to use the 
Quietest fan mode in AUTO, COOL, DRY, FAN or HEAT mode.

12  SLEEP Button

 

 Pressing this button to select sleep mode (   ), 
sleep mode (   ), Sleep mode (   ) and cancel the 
Sleep mode. Circulate between these modes after 
the air conditioner is switched on.

 

Sleep mode 1

 

 In Cool and Dry modes, the set temperature will  increase 1°C 
after an hour, after 2 hours the set temperature will increase 
another 1°C, then continue to run at this setting. In Heat mode: 
the set temperature 
will decrease 1°C, after 2 hours the set temperature 
will decrease another 1°C,  then continue to run at 
this setting.

 

Sleep mode 2

 

 In this mode, the air conditioner will run according to a preset 
sleep temperature curve.

 

In Cool mode

 

(1)  When setting the initial temperature between 16-23°C, 

after turning on the Sleep function, the temperature will 
increase 1°C every hour, after 3°C the temperature will 
be maintained, after 7 hours, the temperature will be 
decreased a further 1°C, after that the unit will keep running 
at this temperature;

 

(2)  When setting the initial temperature between 24°C-27°C, 

after turning on the Sleep function, the temperature will 
increase 1°C in every hour, after 2°C the temperature 
will be maintained, after 7 hours, the temperature will be 
decreased a further 1°C, after 
that the unit will keep running at this temperature;

 

(3)  When setting the initial temperature between 28°C-29°C, 

after turning on the Sleep function, the temperature will 
increase 1°C in the first hour, after 7 hours, the temperature 
will be decreased a further 1°C, after that the unit will keep 
running at this temperature;

 

(4)  When setting the initial temperature to 30°C, after 7 hours 

the temperature will be decreased 1°C, after that the unit 
will keep running at this temperature.

Содержание KSV25HRD

Страница 1: ...1 1 Contents Safety Inverter Split Room Air Conditioner User Manual KSV25HRD KSV35HRD KSV52HRD KSV70HRD KSV80HRD Refrigerant R410A ...

Страница 2: ...s in hotels motels and other residential type environments Bed and breakfast type environments Contents 2 Safety precautions 3 Parts identification 4 Quickstart guide 5 Using the remot e control 6 Features of the remote control 7 Changing batteries 10 Emergency operation 10 Care and cleaning 11 Operation tips 12 Troubleshooting 13 Installation checklist 14 Important notes WARNING caution Contact a...

Страница 3: ...Otherwise it will accumulate dust and may cause a fire Before cleaning the air conditioner please disconnect the power supply in order to eliminate the possibility of electric shock The power supply should be matched with the air conditioner according to the installation manual Air conditioners provided with a supply cord should be connected directly to a power outlet with a suitable safety switch...

Страница 4: ... 10 1 Power cord 2 Remote controller 3 Front panel 4 Filter 5 Horizontal louver 6 Wall pipe 7 Binding tape 8 Connection pipe 9 Drain hose 10 Drain connector 11 Indoor display when active Outdoor unit Air in Air in 11 Air out Air out Name of parts ...

Страница 5: ... be blowed after the unit is stopped to avoid mould X FAN Air Purge When the X fan function is on the fan will continue to run for 2 minutes at low speed after the off button is pressed in order to purge the air conditioner of all moisture to avoid the growth of mould About AUTO RUN When AUTO RUN mode is selected the set temperature will not be displayed on the LCD the unit will be in accordance w...

Страница 6: ...sunlight the air conditioner may not function properly Use curtains to prevent the sunlight from falling on the receiver If other electrical appliances react to the remote control either move these appliances or consult your local dealer Prior to Operation 1 Contact a qualified installer for installation 2 Plug in the power plug properly 3 Do not use a damaged or non standard power cord 4 Do not s...

Страница 7: ...l value is 25 C AUTO COOL DRY FAN HEAT 3 FAN Button By pressing this button Auto Low Medium low Medium Medium high High speed can be progressively selected When the unit is turned on Auto fan speed is the default Under DRY mode only Low fan speed can be set up Medium fan Low fan High fan Medium low fan Medium high fan 4 Button Pressing this button will increase the temperature setting holding this...

Страница 8: ...ol will display permanently Default times for timer on and off are 8 00am and 5 00pm 7 TIME OFF Button Press this key to enter into TIMER OFF setup in which case the OFF icon will blink The method of setting is the same as for TIMER ON 8 SWING V Button Press this button to enable or disable the vertical swing function When disabling the vertical swing function the guiding louver will stay at its l...

Страница 9: ...ay will revert to normal operation 10 I FEEL Button Press this button once to turn on the I FEEL function then the symbol of I FEEL will be displayed The air conditioner will then operate to reach the set temperature at the location of the remote control After this function has started the remote control will send temperature to the main unit every 10 minutes Once the button has been pressed again...

Страница 10: ...es If abnormal operation continues replace with new batteries To operate the air conditioner please point the remote control at the indoor unit in order to improve the sensitivity of the main unit 1 3 4 2 Fig 1 Fig 2 When the remote control is lost or damaged please use the manual switch on the main unit In that case the unit will operate in AUTO mode and the temperature setting or fan speed can n...

Страница 11: ...leaning and maintenance Do not splash water on the units for cleaning as electric shocks may occur Wipe the units with a dry soft cloth or a cloth slightly moistened with water or cleaner not with volatile liquid such as thinner or gasoline Cleaning the Front Panel Remove the front panel Then wipe the front panel with a soft cloth moistened with water to remove any marks NOTE Do not immerse the fr...

Страница 12: ...imum cooling 21 15 21 Maximum heating 27 24 18 Minimum heating 20 5 6 The operating temperature range outdoor temperature for cooling mode is 16 C 48 C and for heating mode is 15 C 24 C Tips for energy saving Do not overcool or overheat Setting temperature at a moderate level helps energy saving Cover windows with a blind or a curtain Blocking sunlight and air from outdoors reduces energy consumpt...

Страница 13: ...rect repair may cause electric shock or fire so please contact an authorised service center for professional repair The following checks prior to contact may save you time and money Problem Cause The unit does not operate The unit does not operate if it is turned on immediately after it is turned off This is to protect the unit You should wait about 3 minutes Odours are emitted Some odours may be ...

Страница 14: ...s the unit securely mounted Is the unit readily accessible without special equipment Has the appropriate size circuit and fuse circuit breaker been fitted Has the unit been tested and confirmed to operate correctly Has the user of the air conditioner been shown how to use the air conditioner CUSTOMER PLEASE RETAIN WITH YOUR PURCHASE DOCUMENTS IN A SAFE PLACE Model Number___________________________...

Страница 15: ...ct claimed is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive a the Appliance is damaged by i accident ii misuse or abuse including failure to properly maintain or service iii normal wear and tear iv power surges electrical storm damage or incorrect power supply v incomplete or improper installation vi incorrect improper...

Страница 16: ...b kelvinator co nz For more information on all Kelvinator appliances or for dimension and installation information call into your retailer phone or email our customer care team or visit our website Kelvinator We are part of the Electrolux family Share more of our thinking at electrolux com au Part No 66129909124 2015 Electrolux Home Products Pty Ltd ABN 51 004 762 341 KMAN_AIRWAVE_UM_Jun15 ...

Отзывы: