background image

 

 

Installation options 

On base cabinet with door   

When constructing the cabinet, suitable precautions must be take 
to  prevent  contact  with  the  casing  of  the  hob,  which  becomes 
very  hot  during  operation.  The  recommended  method  for 
overcoming this problem is illustrated in fig.1 
 
The panel underneath the hob must be easily removable to allow 
the hob to be lacked in position and released incase of servicing 
work                                   
                                                                 

On base cabinet with oven 

The  installation  compartment 
must  have  the  dimensions 
shown  in  figures  2  and  3  and 
must  have  supports  to  allow 
satisfactory  ventilation.  Two 
possible  methods  for  avoiding 
overheating  are  illustrated  in 
figures  3  and  4.  The  electrical 
connections  of  the  hob  and 
oven  must  be  made  separately 
both  for  electrical  reasons  and 
to simplify removal of the oven 
through  the  front  of  the 
cabinet.   
 
Wall  cabinets  or  extractor 
hoods must be at least 650 mm 
above the hob. 

                               
 
 
 

                                                                                                                         

16 

Содержание KHG640SS2

Страница 1: ...Built in Gas Hob KHG950SS2 KHG640SS2 User and Installation Instruction ...

Страница 2: ... Instructions for use 6 Cleaning and maintenance 8 For The Installation Technician Technical data 10 Instructions for the installation technician 10 Electrical connection 13 Adapting to the different types of gas 14 Building into fitted kitchen units 15 ...

Страница 3: ... instructions Suggestions and Advice Information concerning environmental protection This appliance complies with the following EEC Directives 73 23 and 90 683 relating to Low Voltage 89 336 relating to Electromagnetic Compatibility 90 396 relating to Gas Appliances 93 68 relating to the General Standards And subsequent amendments ...

Страница 4: ...technician has declared that it is safe to do so GAS PRESSURE REGULATOR This appliance requires an operating pressure of 2 8 kPa at the appliance A suitable LPG regulator that complies with the requirements of SANS 1237 must be installed IMPORTANT INFORMATION FOR THE USER This appliance may only be installed by a registered LP Gas installer All registered installers are issued with a card carrying...

Страница 5: ...ern Africa The appliance must be installed in accordance with the requirements of SANS 10087 1 and any fire department regulations and or local bylaws applicable to the area If in doubt check with the relevant authority before undertaking the installation Upon completion of the installation you are required to fully explain and demonstrate to the user the operational details and safety practices a...

Страница 6: ...electrical lead is in perfect condition Otherwise contact your dealer before putting the appliance into operation The Manufacturer declines all responsibility in case of failure to comply with the accident prevention regulations Make sure that air is able to circulate freely around the appliance Poor ventilation produced a shortage of oxygen Make sure that the appliance is supplied with the type o...

Страница 7: ...rols or play with the appliance The exposed parts of this appliance heat up during cooking and remain hot for some time even after it is switched off Keep children well away until the appliance has cooled down Cleaning and maintenance Keep the appliance thoroughly cleaned Food residues may cause fire risks Service and parts In the instance of malfunctions Never attempt to repair the appliance your...

Страница 8: ...ble Decommissioned appliances Appliances which are no longer used or usable are not worthless waste Through environment friendly disposal a number of materials used in the production of your appliance can be recovered Find out about the current disposal options from your specialist dealer or your local authority Before scrapping the appliances cut the power supply lead and make it unusable Descrip...

Страница 9: ...ever between the maximum setting and the closed position Symbol present on version with lighting A Burner cap integrated in the Control knob B Lighting plug C Thermocouple D Triple flame cap Dual triple flame version no gas flow maximum gas flow from central burner minimum gas flow from central burner maximum gas flow from outer and central burners simultaneously minimum gas flow from outer and ce...

Страница 10: ...a flame near the burner and proceed as already described If the flame does not light after a few attempts check that the burner cap and flame cap are correctly positioned To turn off the flame turn the control knob clockwise to the symbol Before removing pans from the burners always lower or turn off the flame For correct use of the hob For lower gas consumption and better efficiency Use only flat...

Страница 11: ...arm water and a little liquid detergent Do not use the following products household detergents or bleaches soaped scouring pads not suitable for non stick utensils steel wool scouring pads stain removers for baths or sinks If the hob gets very dirty use specific commercial products Ignition plug Automatic burner ignition is provided when installed by a ceramic plug and a metal electrode B in fig 1...

Страница 12: ...who sold you the appliance or our nearest Service Centre specifying the nature of the problem the model of the equipment Mod the product number Prod No and the serial number Ser No These data are provided in the plate on the cover of this manual Always request the use of original spare parts Warranty conditions You new appliance is covered by a warranty The warranty conditions are provided in full...

Страница 13: ...1 2 Electricity supply AC 220 240v 50 60Hz Battery supply DC 1 5v Instructions for the installation technician CAUTION This appliance must only be installed and used in rooms with permanent ventilation to local standards Installation of the appliance and its connection to the electrical mains must only be carried out by QUALIFIED STAFF Before any procedure it is important to check that the applian...

Страница 14: ...ecessary air may be taken from an adjacent room provided that this room is not a bedroom or a hazardous environment this room is not in a vacuum the ventilation between the room where the appliance is installed and the adjacent room is guaranteed by permanent openings Discharge of flue gases Gas cooking appliances must discharge their flue gases through hoods connected directly to flues or the out...

Страница 15: ...nion must be fitted on the end of the gas train Complete with GJ1 2 threaded nut fitting the gasket between the components as shown in the illustration The gaskets must comply with the local standards Screw the parts together without forcing fit the union so that it points in the direction required then tighten all parts Connection Make the connection to the gas system using a rigid metal pipe and...

Страница 16: ... at least 3 mm of suitable rating for the load and complying with the regulations in force must be installed between the appliance and the mains The switch must not break a contact in the yellow green earth wire The brown live wire connected to the L terminal of the terminal board must always be connected to the live wire of the power supply mains In all cases the power supply lead must be positio...

Страница 17: ...fied or variable a suitable piped gas pressure regulator complying with the standard must be installed on the supply pipeline Setting the minimum level 1 Light the burner as already described 2 Turn the tap to the minimum flame position 3 Remove the control knobs 4 Use a thin straight screwdriver to turn the by pass pin located next to the tap rod see fig B For LPG turn the by pass pin fully clock...

Страница 18: ...n the installation opening Place the special gasket around the bottom edge of the hob It is important to fix this gasket evenly without gaps or overlapping to prevent liquid from seeping under meath the hob 1 Remove the pan stands and the burner caps and turn the hob upside down taking care not to damage the ignition plugs and the thermocouples 2 Place the gasket around the bottom edge of the hob ...

Страница 19: ...o be lacked in position and released incase of servicing work On base cabinet with oven The installation compartment must have the dimensions shown in figures 2 and 3 and must have supports to allow satisfactory ventilation Two possible methods for avoiding overheating are illustrated in figures 3 and 4 The electrical connections of the hob and oven must be made separately both for electrical reas...

Страница 20: ...Cutting out size 17 ...

Страница 21: ...re writing or telephoning When you contact us we need to know Your name Telephone Number Physical Address where appliance is located Model and Serial Number of the appliance Clear and concise details of the fault Customer Care For general enquiries or information regarding Kelvinator appliances contact Customer Care Department Kelvinator P O Box 3657 Johannesburg 2000 South African Customers 010 2...

Страница 22: ...or the account of the purchaser 3 This guarantee is given on condition that only labour parts and accessories supplied by authorised agents are at all times used in connection with the appliance including the installation thereof and that an authorised Kelvinator service agent installs and or services the appliance 4 Kelvinator shall not be responsible for damage of any kind resulting from electri...

Страница 23: ...expiry of 6 six months from the date of purchase the guarantee shall be available only to the original retail purchaser of Kelvinator domestic appliances from an authorised Kelvinator Dealer or Distributor and only where the appliance has been retained for use in the Republic of South Africa 10 Failure to produce documentary proof of the date of original acquisition by the original purchaser to Ke...

Отзывы: