Page
24
6.2 ELECTRICAL DIAGRAMS
KRAD 40M to KRAD 125M
A20
M
l
~
A/S
C/C
P/R
K01
P
A40-1
M01
DR
K01
K30
S16
NT
1
2
3
4
5
6
7
9
10
11
12
L
N
~
HP
S10
M
l
~
M10
HP
S11
ELECTRICAL SUPPLY LINE
SINGLE PHASE + PROTECTION EARTH
CABLES SIZE
ELECTRICAL
SPECIFICATIONS
COMPRESSOR UN 230V/1~/50Hz
MKP
-
66
RLA 1,6A 0,240kW
MKP
-
96
RLA 2,5A 0,393kW
MKP
-
130
RLA
3,1A 0,484kW
MKP
-
168
RLA
4,0A 0,620kW
MKP
-
240
RLA 5,7A 0,870kW
FAN MOTOR UN 230V/1~/50Hz
MKP
-
66
RLA
0,20A 0,035kW
MKP
-
96
RLA
0,68A 0,095kW
MKP
-1
30
RLA 0,68A 0,095kW
MKP
-
168
RLA 0,68A 0,095kW
MKP
-
240
RLA 0,68A 0,095kW
S01 MAIN PROTECTION AND DISCONNECTING MEANS
SHALL BE PROVIDED BY THE INSTALLER OF RESIDUAL CURRENT AUTOMATIC CIRCUIT BREAKER
MKP
-
66
MKP
-
96
MKP
-
130
MKP
-
168
MKP
-
240
3x1,5mm2 3x1,5mm2 3x1,5mm2 3x1,5mm2 3x1,5mm2
1
4
1
4
3
4
2
4
19
4
4
4
3
10
10
10
12
11
SP
EV3
FIELD INSTALLED
MAXIMUM SET: %15
EV3: Controller SP: Power supply AL: Alarm contacts A20: Drain supply DR: Drain valve relay A40-1:Start capacitor K01: Compressor start relay K02: Compressor motor contactor
K30: Alarm relay S10: Fan pressure switch S11: High pressure switch S16: Filter service contact (optional)
M01:
Compressor motor
M10: Fan motor P: Compressor motor overload protector
NT: Temperature sensor (NTC) HP indicates high pressure
5
6
7
AL
PE
Содержание KRAD M Series
Страница 2: ...Page 2...
Страница 26: ...Page 26 6 3 KRAD M ID DIAGRAM DRAWINGS GENERAL ARRANGEMENTS...
Страница 38: ...Page 38 8 KRAD M EXPLODED DIAGRAMS SPARE PART LISTS...