Kelly Jaguar series KLS-N Sinusoidal Brushless PM Motor Controller User
’s Manual
V2.9
6
Kelly KLS-RMO------Opto-isolated Racing Motor controllers
Model
Nominal
Voltage
Max
Operating
Voltage
Boost
Current
30 seconds
Continuous
Current
Continuous Current
(liquid cooling)
KLS84150RMO
48-84V
36-100V
1500A
375A
600A
KLS84180RMO
48-84V
36-100V
1800A
450A
720A
KLS1170RMO
48-110V
36-132V
700A
175A
280A
KLS1185RMO
48-110V
36-132V
850A
210A
340A
KLS11100RMO
48-110V
36-132V
1000A
250A
400A
KLS11130RMO
48-110V
36-132V
1300A
325A
520A
KLS11160RMO
48-110V
36-132V
1600A
400A
640A
KLS1460RMO
48-144V
36-173V
600A
150A
240A
KLS1480RMO
48-144V
36-173V
800A
200A
320A
KLS14100RMO
48-144V
36-173V
1000A
250A
400A
KLS14120RMO
48-144V
36-173V
1200A
300A
480A
KLS1680RMO
48-168V
36-200V
800A
200A
320A
KLS16100RMO
48-168V
36-200V
1000A
250A
400A
Chapter 3 Wiring and Installation
3.1 Mounting the Controller
The controller can be oriented in any position which should be as clean and dry as possible,
and if necessary, shielded with a cover to protect it from water and contaminants.
To ensure full rated output power, the controller should be fastened to a clean, flat metal
surface with four screws. Applying silicon grease or some other thermal conductive material to
contact surface will enhance thermal performance.
Proper heat sinking and airflow are vital to achieve the full power capability of the controller.
The case outline and mounting holes
’ dimensions are shown below.