Kelly KLS-S Brushless Motor Controller User’s Manual
V1.5.02
20
x
ON
ON
Reverse
x
OFF
ON
Forward
Disable
Disable
x
OFF
x
Forward
x
ON
x
Reverse
Note: X means can be on or off
Figure 4.2
(21)Boost:If enabled,the controller will output max power for a while.
Boost function is just full throttle position when you turn on boost switch even if the throttle is not
operated at all.
The boost function is still based on limiting of the motor current and battery current settings in
user program.
Suggestion: Set according to the practical situation, factory default is Disable.
(22)Foot switch:It is used for microswitch.If enabled,the controller will only accept the throttle
signal after received the valid foot switch signal.
If there is no foot switch signal,the controller will ignore the throttle signal.
Suggestion: Set according to the practical situation, factory default is Disable.
(23)Cruise Control:Value range: Enable and Disable
If enable,if you hold throttle at certain position about 3-4 seconds,the controller will get into
Cruise control.
Release throttle and turn the throttle again or turn on the brake switch will make the Cruise
control quit.
Suggestion:factory default is Disable.
(24)Change Direction:
If the direction is not what you expected after finish the Identification angle operation,please just
choose Change Direction item.
Please click Write button to activate Change Direction function.The motor direction will be what
you expected after the power supply is reset.
Suggestion:factory default is Disable.
4.2 Step 2
(1)Motor Poles: Motor Poles, The pair pole number*2. Range: 2~128
Suggestion: Set according to the real motor poles on the nameplate of the motor, factory default
is at 8.
(2)Speed Sensor Type: Speed Sensor Type, 2:Hal, 3:Resolver, 4:Line Hall. Range: 2~4
Different sensors type.By defualt,it is set at 2