Kelly KLS-D Brushless Motor Controller User’s Manual
V 1.5.02
21
or short-circuit
fault.
3,4
¤¤¤ ¤¤¤¤
Non-zero throttle on
direction change
Controller won’t allow a direction change unless the
throttle or speed is at zero. Fault clears when throttle
is released.
4,1
¤¤¤¤ ¤
Regen or Start-up
over-voltage
Motor drive is disabled if an over-voltage is detected
at start-up or during regen. The voltage threshold
detection level is set during configuration.
4, 2
¤¤¤¤ ¤¤
Hall sensor error
1. Incorrect or loose wiring or a damaged hall sensor.
2. Also be caused by incorrect hall angle
configuration (60 degree or 120 degree)
4, 3
¤¤¤¤ ¤¤¤
Motor
over-temperature
Motor temperature has exceeded the configured
maximum. The controller will shut down until the
motor temperature cools down.
Customers may read error codes in PC software or Android Tablet