background image

Kelly KLS-H Brushless Motor Controller User

’s Manual 

   

 

V 1.11

 

                                                                                                                                         

 

21

 

If there is no foot switch signal, the controller will ignore the throttle signal. 
Suggestion: Set according to the practical situation, factory default is Disable. 
 
(26)Cruise Control: Value range: Enable and Disable 
If  enable,  if  you  hold  throttle  at  certain  position  about  3-4  seconds,  the  controller  will  get  into 
Cruise control. The Cruise function can not be activated in reversing direction. 
Release  throttle  and  turn  the  throttle  again  or  turn  on  the  brake  switch  will  make  the  Cruise 
control quit. 
Suggestion: factory default is Disable. 
 
(27)Change Direction: 
If  the direction  is  not  what  you  expected  after finish the  Identification  angle  operation, please 
just choose Change Direction item. 
Please click Write button to activate Change Direction function. The motor direction will be what 
you expected after the power supply is reset. 
Suggestion: factory default is Disable. 

4.2 Step 2 

 
(1)Motor Poles: Motor Poles, The pair pole number*2. Range: 2~128 
Suggestion: Set according to the real motor poles on the nameplate of the motor, factory default 
is at 8. 
 
(2)Speed Sensor Type: Speed Sensor Type, 2:Hal, 3:Resolver, 4:Line Hall. Range: 2~4 
Different sensors type. By default, it is set at 2 
If you have a motor with 5V,Sin/Cosin, GND speed sensors, please choose it at 4.And please 
inquire the KLS-8080IPS model before ordering. 
 
(3)Resolver Poles: Resolver Poles, The pair pole number*2. Range: 2~32 
It is only used for the Resolver sensor type. 
 
(4)Motor Temp Sensor: Motor Temp Sensor, 0

None,1: KTY84-130 or 150,2:KTY83-122.Range 

0-2 
High Temp Cut Out 

°

C: Motor High Temp Cut Out, nominal value 130

°

C. Range: 60~170 

Resume 

°

C:  Motor  High  Temp  Resume  Temp,  nominal  value  110

°

C.  The  controller  will 

resume work when the motor temp is at 110 degrees inside. Range: 60~170 
 

4.3 Step 3 

(1)RLS_TPS  Brk  %:  RLS  TPS  Braking  Percent,  the  percent  of  Releasing  Pedal  BRK  in  max 
braking. Range: 0~50     
This is used to adjust the regen current  of  releasing throttle  regen mode type. The regen will 
happen as long as the throttle is released completely. 
Factory set is 0 

Содержание KLS2422H

Страница 1: ...Controller User s Manual Devices Supported Rev 1 11 July 2022 KLS2422H KLS2430H KLS2445H KLS2475H KLS6022H KLS6030H KLS7218H KLS7230H KLS7245H KLS7275H KLS8422H KLS8430H KLS72501 8080H KLS72601 8080H KLS72701 8080H KLS84701 8080H KLS96301 8080H KLS96401 8080H KLS96501 8080H KLS96601 8080H ...

Страница 2: ...s 4 2 3 Specifications 5 2 4 Name Regulation 6 Chapter 3 Wiring and Installation 6 3 1 Mounting the Controller 7 3 2 Connections 11 3 3 Installation Check List 15 Chapter 4 Programmable Parameters 16 4 1 Step 1 16 4 2 Step 2 21 4 3 Step 3 21 4 4 How to use Identification angle operation function 23 Chapter 5 Maintenance 27 5 1 Cleaning 27 5 2 Configuration 27 Table 1 Error Codes 28 Contact Us 30 ...

Страница 3: ...ss motor It uses high power MOSFET s and SVPWM and FOC to achieve efficiencies of up to 99 in most cases A powerful microprocessor brings in comprehensive and precise control to the controllers It also allows users to adjust parameters conduct tests and obtain diagnostic information quickly and easily People can program the KLS controller on PC software and Android App There is one more choice for...

Страница 4: ...switch reversing switch forward switch and Boost switch 11 3 analog 0 5V inputs that default to throttle input Brake analog input and motor temperature input 12 Copy signal of one of hall sensors 13 Configurable boost switch Enables the maximum output power achievable if the switch is turned on The effect is the same as full throttle position even if you don t turn throttle at all 14 12V brake swi...

Страница 5: ...ery voltage 13 Rugged aluminum housing for maximum heat dissipation and harsh environment 14 Rugged high current terminals and rugged aviation connectors for small signal 15 Thermal protection current cut back warning and shutdown on high temperature 16 Controller can do auto_Identification angle for different degrees of hall sensors 17 Configurable high pedal protection the controller will not wo...

Страница 6: ... batteries for KLS96xxx 8080H model So All KLS H and KLS 8080H model are non isolated type controllers Supply Current PWR 30mA Typical Configurable battery voltage range B KLS24V model B Max operating range 20V to 30V Standard Throttle Input 0 5 Volts 3 wire resistive pot 1 4 Volts hall active throttle Throttle Input 0 5 Volts Can use 3 wire pot to produce 0 5V signal Full Power Operating Temperat...

Страница 7: ...N bus protocol Kelly KLS H Brushless Motor Controller Model 30 seconds Current Amp Continuous Current Amp Battery Voltage Volt Max Operating Voltage Volt KLS2422H 220 88 20 24 30 KLS2430H 350 120 20 24 30 KLS2445H 350 140 20 24 30 KLS2475H 500 200 20 24 30 KLS6022H 220 88 40 60 80 KLS6030H 350 120 40 60 80 KLS7218H 200 80 40 72 86 KLS7230H 300 100 40 72 86 KLS7245H 350 140 40 72 86 KLS7275H 500 20...

Страница 8: ...full rated output power the controller should be fastened to a clean flat metal surface with four screws Applying silicon grease or some other thermal conductive material to contact surface will enhance thermal performance Proper heat sinking and airflow are vital to achieve the full power capability of the controller The case outline and mounting holes dimensions are shown in Figure 1 2 3 4 Figur...

Страница 9: ...Kelly KLS H Brushless Motor Controller User s Manual V 1 11 8 Figure 2 KLS2445H KLS7245H mounting holes dimensions dimensions in millimeters ...

Страница 10: ...Kelly KLS H Brushless Motor Controller User s Manual V 1 11 9 Figure 3 KLS2475H KLS7275H mounting holes dimensions dimensions in millimeters ...

Страница 11: ...Kelly KLS H Brushless Motor Controller User s Manual V 1 11 10 Figure 4 KLS72xxx 8080H KLS96xxx 8080H mounting holes dimensions dimensions in millimeters ...

Страница 12: ...e same pin as pin2 When Boost is disabled in the user program the pin2 can be used as brake variable regen mode When Boost is enabled the brake analog regen mode is inactivated automatically Both Boost and Brake variable regen mode can not be used at the same time Figure 5 waterproof connector DJ7091Y 2 3 11 Pin Definition 14 REV_SW Reverse switch input Orange 6 RTN Signal return or power supply r...

Страница 13: ...put Raddle 5 5V 5V supply output 40mA Purple 18 Hall A Hall phase A Yellow 17 Hall B Hall phase B Dark Green 16 Hall C Hall phase C Dark Blue Notes 1 All RTN pins are internally connected 2 Meter function is to copy either of hall sensors 3 Switch to 12V is active Open switch is inactive Caution Do not apply power until you are certain the controller wiring is correct and has been double checked W...

Страница 14: ...Kelly KLS H Brushless Motor Controller User s Manual V 1 11 13 3 2 2 Standard Wiring of KLS H Controller Figure 6 KLS H controller standard wiring Battery voltage can be used for controller supply ...

Страница 15: ...7 Wiring of brake switch 12V 12V is provided by external source Figure 8 Wiring of brake switch 12V 12V is provided by KLS D controller on pin11 Figure 9 Wiring diagram for motor temperature sensor NOTE The motor temperature sensor and brake switch used the different I O port on latest version Both functions can be used at the same time KLS controller can support KTY84 150 and KTY84 130 thermistor...

Страница 16: ...P connector for communication interface on KLS H controller 3 3 Installation Check List Before operating the vehicle complete the following checkout procedure Use buzzer code as a reference as listed in Table 1 Caution Put the vehicle up on blocks to get the drive wheels off the ground before beginning these tests Do not allow anyone to stand directly in front of or behind the vehicle during the c...

Страница 17: ... working environment so as to be at its best The default parameters of the controller are not recommended for all applications Make sure set the proper parameters before making any test to avoid danger Customers can do program on PC software or Android App The Android Tablet is prefered First of all people need to do Identification angle function for KLS controller before running the motor The con...

Страница 18: ...normal Please fill in 170 for Identification Angle item in user program Then please click Write button in user program Please wait a few seconds before restart the power supply You will see some info on Monitor screen after power supply is reset If you see Reset error on the Monitor screen that is to say the auto_Identification is finished You can see 85 in the Identification Angle item again And ...

Страница 19: ...he practical situation factory default is 80 5V 4 0V 11 Brake sensor type Brake sensor type for brake variable regen mode 1 0 5V 3 wire 0 5K pot 5K is normal 2K 20K can be used 2 Hall active throttle or pedal Range 1 2 12 Brake sensor Dead Low Brake sensor Dead Zone Low Range 5 40 Functional description Set throttle effective starting point Suggestion Set according to the practical situation facto...

Страница 20: ...ntroller will detect the current pedal position or signal When the switch is in neutral poistion If the throttle got effective output signal the controller will not operate and report fault code Suggestion Set according to the practical situation factory default is Disable 22 Joystick function If enable the controller can drive the motor on two directions without using any reversing switch Just on...

Страница 21: ...e OFF OFF x Neutral OFF ON x Reverse ON OFF x Forward ON ON x Neutral Disable Enable x OFF OFF Can t operate x ON OFF Can t operate x ON ON Reverse x OFF ON Forward Disable Disable x OFF x Forward x ON x Reverse Note X means can be on or off Figure 4 1 25 If enabled the controller will output max power for a while Boost function is just full throttle position when you turn on boost switch even if ...

Страница 22: ...2 Step 2 1 Motor Poles Motor Poles The pair pole number 2 Range 2 128 Suggestion Set according to the real motor poles on the nameplate of the motor factory default is at 8 2 Speed Sensor Type Speed Sensor Type 2 Hal 3 Resolver 4 Line Hall Range 2 4 Different sensors type By default it is set at 2 If you have a motor with 5V Sin Cosin GND speed sensors please choose it at 4 And please inquire the ...

Страница 23: ...Brk BRK_SW Braking Percent the percent of BRK_SW in max braking Range 0 50 The brake switch regen mode You have to turn on the brake switch after the throttle is released for the regen to occur Factory set is 10 8 Brake Analog regen Brk It is used to adjust the max regen percentage of brake variable regen mode This regen mode doesn t need brake switch to support any more for KLS controller 8 Torqu...

Страница 24: ...ration before running motor for all KLS controllers The Identification angle operation can be done in PC program or Android App Tablet or Cell Phone KLS D H controller is designed for BLDC motor with three hall sensors By default the speed sensor type is set at 2 from factory setting for KLS D H controller 1 Please hook up the controller for identification angle operation according to the wiring d...

Страница 25: ...User s Manual V 1 11 24 Customers also can use a Z TEK USB to RS232 cable and SM 4A DB9 RS232 Converter to connect the controller to an Android Tablet The third option is customers can buy our Bluetooth converter to connect the controller to ...

Страница 26: ... item is at 85 But customers still need to run identification angle operation before driving Because the 85 means this controller finished the identification angle operation with the motor in factory before shipment Your motor is different from the motor from controller supplier 5 Please fill 170 in the identification angle item And please click the write button The user program will give a pop up...

Страница 27: ...d there are other error codes such as Identify error hall err etc please return to the first picture of user program Please write 85 instead in identification angle by manual If there are no any error codes you can not write it back to 85 by manual Please wait longer time until the error codes occur Please don t keep 170 in the identification angle item when you want to turn off the power supply O...

Страница 28: ...tions to the bus bars if fitted are tight To avoid physically stressing the bus bars use two well insulated wrenches 5 2 Configuration You can configure the controller with a host computer through either an RS232 or USB port Disconnect motor wiring from controller for configuring existing parameters in the user program or Android APP If this operation is too much extra job for you please make sure...

Страница 29: ...user program Table 1 Error Codes Buzzer Error Codes Code Explanation Solution 1 1 Automatic error identification 1 Wrong wiring of motor phase line or hall Please suspend the motor when enable Auto Identify function 1 2 Over voltage error 2 Battery voltage is too high for the controller Check battery volts and configuration 3 Regeneration over voltage Controller will have cut back or stopped regen...

Страница 30: ...urrent momentarily high or low battery voltage This can happen during normal operation 3 3 Hall throttle is open or short circuit When the throttle is repaired a restart will clear the fault 3 4 Angle sensor error 1 Speed sensor type error customers may set the correct sensor type through user program or App Please download how to use Identification function instruction from our website 2 Incorrec...

Страница 31: ...oller User s Manual V 1 11 30 Contact Us Kelly Controls Home Page http www KellyController com Download user manual instructions and user program www kellycontroller com support php E mail Sales Kelly Controls com Phone 01 224 637 5092 ...

Отзывы: