26
acceleration and good power.
Chapter 4 Programmable Parameters
KLS Configuration program allow users to set parameters according to the vehicle actual
working environment so as to be at its best.
The default parameters of the controller are not recommended for all applications. Make
sure set the proper parameters before making any test to avoid danger.
Customers can do program on PC software or Android App. The Android Tablet is prefered.
First of all, people need to do Identification angle function for KLS controller before running the
motor. The controller needs to be connected to batteries, motor and throttle before Identification
operation. That is to say, it is not enough to connect only power supply(PWR=pin7) to batteries
for Identification Angle operation.
Please download the instruction how to use Identification angle function from our website.
www.kellycontroller.com/support.php
4.1 Step 1
(1)Low Volt: The min voltage of reporting this fault - Range 20~86, depending on model.
Controller will not operate when battery voltage is near the value so as to protect battery.
Suggestion: Set according to the practical situation.
(2)Over Volt: The max voltage of reporting this fault - Range 20~86, depending on model.
Controller will not operate when battery voltage is higher than the value so as to protect battery
and controller.
Suggestion: Set according to the practical situation.
By default, It is 86V for 72V controller.
Controller Rated voltage Under Voltage Range (V) Over Voltage Range(V)
24V
20~30
20~30
60V
40~80
40~80
Содержание KLS1490RMO
Страница 9: ...9 Figure 1 KLS8425RM mounting holes dimensions dimensions in millimeters...
Страница 10: ...10 Figure 2 KLS7235RM KLS7240RM KLS8430RM KLS8445RM mounting holes dimensions dimensions in millimeters...
Страница 11: ...11 Figure 3 KLS7245RM mounting holes dimensions dimensions in millimeters...
Страница 12: ...12 Figure 3 KLS8428RM mounting holes dimensions dimensions in millimeters...
Страница 13: ...13 Figure 4 KLS8460RM mounting holes dimensions dimensions in millimeters...
Страница 14: ...14 Figure 4 KLS7250RM KLS7260RM mounting holes dimensions dimensions in millimeters...
Страница 17: ...17 Figure 6 KLS RMO model with Sealed Aluminium Housing mounting holes dimensions dimensions in millimeters...
Страница 19: ...19 3 2 Connections 3 2 1 Pin definition of KLS N Controller Figure 10 waterproof connector...
Страница 20: ...20 Figure 11 Compact connectors...
Страница 35: ...35 2 Please connect the controller to user program by using an USB to RS232 cable and SM 4A DB9 RS232 Converter...